SIMATIC S7-300 – SM 323 Digital Input / Output Modules – Siemens Digital Modules
USD $ 180.94 – USD $ 815.76
SKU: N/A
Digital input/output modules are suitable for connecting
- Switches and 2-wire proximity switches (BEROs)
- Solenoid valves, contactors, small-power motors, lamps and motor starters.
Siemens Digital Input/Output Modules SIMATIC S7-300 Product Specifications:
Article number | 6ES7323-1BH01-0AA0 | 6ES7323-1BL00-0AA0 |
SM323, 8DI/8DO, DC24V, 0,5A | SM323, 16DI/DO, DC24V, 0,5A | |
Supply voltage | ||
Load voltage L+ | ||
● Rated value (DC) | 24 V | 24 V |
● permissible range, lower limit (DC) | 20.4 V | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V | 28.8 V |
Input current | ||
from load voltage L+ (without load), max. | 40 mA | 80 mA |
from backplane bus 5 V DC, max. | 40 mA | 80 mA |
Power loss | ||
Power loss, typ. | 3.5 W | 6.5 W |
Digital inputs | ||
Number of digital inputs | 8 | 16 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes |
Number of simultaneously controllable inputs | ||
horizontal installation | ||
— up to 40 °C, max. | 16 | |
— up to 60 °C, max. | 8 | 8 |
vertical installation | ||
— up to 40 °C, max. | 8 | 16 |
Input voltage | ||
● Type of input voltage | DC | DC |
● Rated value (DC) | 24 V | 24 V |
● for signal “0” | -30 to +5 V | -30 to +5 V |
● for signal “1” | 13 to 30V | 13 to 30V |
Input current | ||
● for signal “1”, typ. | 7 mA | 7 mA |
Input delay (for rated value of input voltage) | ||
for standard inputs | ||
— at “0” to “1”, min. | 1.2 ms | 1.2 ms |
— at “0” to “1”, max. | 4.8 ms | 4.8 ms |
— at “1” to “0”, min. | 1.2 ms | 1.2 ms |
— at “1” to “0”, max. | 4.8 ms | 4.8 ms |
Cable length | ||
● shielded, max. | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m |
Digital outputs | ||
Number of digital outputs | 8 | 16 |
Short-circuit protection | Yes | Yes |
● Response threshold, typ. | 1 A | 1 A |
Limitation of inductive shutdown voltage to | L+ (-53 V) | L+ (-48 V) |
Controlling a digital input | Yes | Yes |
Switching capacity of the outputs | ||
● on lamp load, max. | 5 W | 5 W |
Load resistance range | ||
● lower limit | 48 Ω | 48 Ω |
● upper limit | 4 kΩ | 4 kΩ |
Output voltage | ||
● for signal “1”, min. | L+ (-0.8 V) | L+ (-0.8 V) |
Output current | ||
● for signal “1” rated value | 0.5 A | 0.5 A |
● for signal “1” permissible range, min. | 5 mA | 5 mA |
● for signal “1” permissible range, max. | 0.6 A | 0.6 A |
● for signal “1” minimum load current | 5 mA | 5 mA |
● for signal “0” residual current, max. | 0.5 mA | 0.5 mA |
Output delay with resistive load | ||
● “0” to “1”, max. | 100 µs | 100 µs |
● “1” to “0”, max. | 500 µs | 500 µs |
Parallel switching of two outputs | ||
● for uprating | No | No |
● for redundant control of a load | Yes; only outputs of the same group | Yes; only outputs of the same group |
Switching frequency | ||
● with resistive load, max. | 100 Hz | 100 Hz |
● with inductive load, max. | 0.5 Hz | 0.5 Hz |
● with inductive load (acc. to IEC 60947-5-1, DC13), max. | 0.5 Hz | |
● on lamp load, max. | 10 Hz | 100 Hz |
Total current of the outputs (per group) | ||
horizontal installation | ||
— up to 40 °C, max. | 4 A | 4 A |
— up to 60 °C, max. | 4 A | 3 A |
vertical installation | ||
— up to 40 °C, max. | 4 A | 2 A |
Cable length | ||
● shielded, max. | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m |
Encoder | ||
Connectable encoders | ||
● 2-wire sensor | Yes | Yes |
— permissible quiescent current (2-wire sensor), max. | 2 mA | 1.5 mA |
Interrupts/diagnostics/status information | ||
Alarms | No | No |
Diagnostics function | No | No |
Diagnostics indication LED | ||
● Status indicator digital input (green) | Yes | Yes |
● Status indicator digital output (green) | Yes | Yes |
Potential separation | ||
Potential separation digital inputs | ||
● between the channels | Yes | Yes |
● between the channels, in groups of | 8 | 16 |
● between the channels and backplane bus | Yes; Optocoupler | Yes; Optocoupler |
Potential separation digital outputs | ||
● between the channels | Yes | Yes |
● between the channels, in groups of | 8 | 8 |
● between the channels and backplane bus | Yes; Optocoupler | Yes; Optocoupler |
Isolation | ||
Isolation tested with | 500 V DC | 500 V DC |
connection method / header | ||
required front connector | 20-pin | 40-pin |
Dimensions | ||
Width | 40 mm | 40 mm |
Height | 125 mm | 125 mm |
Depth | 120 mm | 120 mm |
Weights | ||
Weight, approx. | 220 g | 260 g |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details