SIMATIC S7-300 – FM 352-5 High-Speed Boolean Processor – Siemens Function Modules
USD $ 918.16
SKU: 6ES7352-5AH01-0AE0
The FM 352-5 High-speed Boolean processor offers extremely fast binary functions and some of the quickest switching procedures ever possible.
Siemens Function Modules SIMATIC S7-300 Product Specifications:
Article number | 6ES7352-5AH01-0AE0 |
FM 352-5, Boolean Processor 12DE/8DA | |
Supply voltage | |
Load voltage L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Input current | |
from load voltage1L+, max. | 150 mA; typ. 60 mA |
from load voltage 2L+ (without load), max. | 200 mA; typ. 60 mA, DI/DO supply |
from load voltage 3L+ (with encoder), max. | 600 mA; typ. 80 mA plus encoder supply |
from load voltage 3L+ (without load), max. | 200 mA; typ. 80 mA |
from backplane bus 5 V DC, typ. | 135 mA |
Encoder supply | |
5 V encoder supply | |
● 5 V | Yes |
● Short-circuit protection | Yes; Electronic overload protection; no protection on applying a normal or counter voltage. |
● Output current, max. | 250 mA |
24 V encoder supply | |
● 24 V | Yes |
● Short-circuit protection | Yes; Overvoltage and overheating protection if overloaded; diagnostics if output reaches temperature limit; no protection on applying a normal or counter voltage |
● Output current, max. | 400 mA |
Power loss | |
Power loss, typ. | 6.5 W |
Memory | |
Type of memory | RAM |
Memory size | 128 kbyte; required for operation, MMC |
Digital inputs | |
Number of digital inputs | 8; Standard and up to 12 with 24 V DC encoder inputs as digital inputs |
Input voltage | |
● Rated value (DC) | 24 V |
● for signal “0” | -30 to +5 V |
● for signal “1” | +11 to +30V |
Input current | |
● for signal “0”, max. (permissible quiescent current) | 1.5 mA |
● for signal “1”, typ. | 3.8 mA |
Input delay (for rated value of input voltage) | |
● Input frequency (with a time delay of 0.1 ms), max. | 200 kHz |
● programmable digital filter delay | None, 5 µs, 10 µs, 15 µs, 20 µs, 50 µs, 1.6 ms |
● Minimum pulse width for program reactions | 1 µs, 5 µs, 10 µs, 15 µs, 20 µs, 50 µs, 1,6 ms |
for standard inputs | |
— at “0” to “1”, max. | 3 µs; typ. 1.5 µs |
Cable length | |
● shielded, max. | 600 m |
● unshielded, max. | 100 m; Shielded cable recommended if filtering delay is set to less than 1.6 ms |
Digital outputs | |
Number of digital outputs | 8 |
Current-sinking | Yes |
Current-sourcing | No |
Short-circuit protection | Yes; Overvoltage protection, thermal protection |
● Response threshold, typ. | 1.7 to 3.5 A |
Limitation of inductive shutdown voltage to | 2M -45 V typ., (-40 V to -55 V); comment: no protection against inductive kickback >55 mJ |
Controlling a digital input | No |
Switching capacity of the outputs | |
● on lamp load, max. | 5 W |
Output voltage | |
● Rated value (DC) | 24 V |
● for signal “0”, max. | 28.8 V |
● for signal “1”, max. | 0.5 V |
Output current | |
● for signal “1” rated value | 0.5 A; At 60 °C |
● for signal “1” permissible range for 0 to 60 °C, min. | 5 mA |
● for signal “1” permissible range for 0 to 60 °C, max. | 600 mA |
● for signal “0” residual current, max. | 1 mA |
Output delay with resistive load | |
● “0” to “1”, max. | 1 µs; 0.6 µs 50 mA / 1.0 µs 0.5 A |
● “1” to “0”, max. | 1.5 µs; 1.7 µs 50 mA / 1.5 µs 0.5 A |
Parallel switching of two outputs | |
● for uprating | Yes; 2 |
Switching frequency | |
● with resistive load, max. | 100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A |
● with inductive load, max. | 2 Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes |
● on lamp load, max. | 10 Hz |
Cable length | |
● shielded, max. | 600 m |
● unshielded, max. | 100 m |
Encoder | |
Connectable encoders | |
● Incremental encoder (symmetrical) | Yes |
● Incremental encoder (asymmetrical) | Yes |
● Absolute encoder (SSI) | Yes |
● 2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Encoder signals, incremental encoder (symmetrical) | |
● Trace mark signals | A, notA, B, notB |
● Zero mark signal | N, notN |
● Input voltage | 5 V difference signal (phys. RS 422) |
● Input frequency, max. | 500 kHz |
● Cable length, shielded, max. | 100 m; 100 m with 24 V supply and 500 kHz; 32 m with 5 V supply and 500 kHz |
Encoder signals, incremental encoder (asymmetrical) | |
● Trace mark signals | A, B |
● Zero mark signal | N |
● Input voltage | 24 V |
● Input frequency, max. | 200 kHz |
● Cable length, shielded, max. | 50 m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, 50 m shielded, max. |
Encoder signals, absolute encoder (SSI) | |
● Data signal | DATA, notDATA |
● Clock signal | CK, notCK |
● Telegram length, parameterizable | 13 or 25 bit |
● Clock frequency, max. | 1 MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz |
● Cable length, shielded, max. | 320 m; At 125 kHz |
● Monoflop time | settable: 16/32/48/64 µs |
● Listening mode | Yes; one or two stations |
● Multiturn | Yes; 25 bit message frame |
Encoder signal evaluation | |
● Counting direction, forward | Yes |
● Counting direction, backward | Yes |
Response times | |
Input- to output response time | 5 V input to 24 V output, 0 filter: 1 to 4 µs (typ.); 24 V input to 24 V output, 0 filter: 2 to 6 µs (typ.) |
Interfaces | |
Point-to-point connection | |
● Updating times | PLC interface: 1.7 ms |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes; 1L, 2L, 3L missing; MMC error; output overload (8); encoder supply overload; differential wire break; parameterization errror; SSI message frame overflow |
● Hardware interrupt | Yes; 8 available; for generation by user program |
Diagnoses | |
● Wire-break in signal transmitter cable | Yes |
● Overflow/underflow | Yes |
● missing load voltage | Yes |
Diagnostics indication LED | |
● RUN/STOP LED | Yes |
● Module supply 5 V DC (green) | Yes |
● I/O status IOF (red) | Yes |
● Micro Memory Card error MCF (red) | Yes |
● Group error SF (red) | Yes |
● Status indicator digital input (green) | Yes; I 0 to I 11 |
● Status indicator digital output (green) | Yes; Q 0 to Q 7 |
● Overload encoder supply voltage 24 V F (red) | Yes |
● Overload encoder supply voltage 5 V F (red) | Yes |
Counter | |
Counting range, description | Counting range (16-bit counters): -32 768 to 32 767 (user-specific within this range); counting range (32-bit counters): -2 147 483 648 to 2 147 483 647 (user-specific within this range) |
Counting range, lower limit | -2 147 483 648 |
Counting range, upper limit | 2 147 483 647 |
Counting mode | |
● Counting mode, individual | Yes |
● Counting mode, continuous | Yes |
● Counting mode, periodic | Yes |
Potential separation | |
between 1L and 2L and 3L | Yes |
Potential separation digital inputs | |
● Potential separation digital inputs | Yes; Yes CPU, I/O and sensor units are isolated |
Ambient conditions | |
Ambient temperature during operation | |
● min. | 0 °C |
● max. | 60 °C |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
configuration / header | |
configuration / programming / header | |
● Program cycle time (scan) | 1 µs |
connection method / header | |
required front connector | 1x 40-pin |
Dimensions | |
Width | 80 mm |
Height | 125 mm |
Depth | 120 mm |
Weights | |
Weight, approx. | 434 g; Module weight: approx. 434 g (with 1L connection and without I/O connection or MMC); shipping weight: approx. 500 g (with bus and 1L connection and without I/O connection or MMC) |
Weight | 0.537 kg |
---|---|
Dimensions | 12.9 × 15.4 × 8.9 cm |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details