$ 203.78
Due to the customized IC and optical design, high precision detection is fulfilled with directivity and visibility achievable only by laser. The laser adopted is Class 1 (IEC / JIS / FDA / GB) laser that is safe to use, so that there is no need to separate the areas of sensor usage. |
Type | Thru-beam | ||
---|---|---|---|
Minute object detection | Long sensing range | ||
Model No. | NPN output | EX-L211 | EX-L212 |
PNP output | EX-L211-P | EX-L212-P | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||
Sensing range | 1 m 3.281 ft | 3 m 9.843 ft | |
Emission spot size (Typical) | Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal) (at a sensing distance of 1 m) |
Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal) (at a sensing distance of 1 m) (Note 2) |
|
Sensing object | Opaque object of ø2 mm ø0.079 in or more | Opaque object of ø3 mm ø0.118 in or more | |
Minimum sensing object (Typical) (Note 3) |
Opaque object of ø0.3 mm ø0.012 in | – | |
Repeatability | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | ||
Repeatability (Typical) (perpendicular to sensing axis) (Note 3) |
0.01 mm 0.0004 in or less (all area) |
– | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Current consumption | Emitter: 10 mA or less, Receiver: 10 mA or less | ||
Output | <NPN output type> NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 26.4 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current) 1 V or less (at 16 mA sink current) <PNP output type> |
||
Output operation | Light-ON / Dark-ON selectable by the output operation switching input | ||
Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) | ||
Response time | 0.5 ms or less | ||
Operation indicator | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | ||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | ||
Power indicator | Green LED (lights up when the power is ON) (incorporated on the emitter) | ||
Sensitivity adjuster | Continuously variable adjuster (receiver) | – | |
Protection | IP67 (IEC) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition), Storage: -30 to +70 ℃ -22 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | ||
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | ||
Emitting element | Red semiconductor laser Class 1 (IEC / JIS / FDA / GB) (Note 4) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) |
||
Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | ||
Cable | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | ||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m 328.084 ft both emitter and receiver). | ||
Weight | Net weight: Emitter; 40 g approx., Receiver; 40 g approx., Gross weight: 90 g approx. |
||
Accessory | MS-EXL2-2 (Mounting plate): 2 pcs. |
Notes :
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉ |
---|---|
2) | In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value). |
3) | Typical values when the sensitivity adjuster is optimally adjusted. |
4) | This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
Type | Retroreflective | Spot reflective | |
---|---|---|---|
Long sensing range | Minute object detection | ||
Model No. | NPN output | EX-L291 | EX-L221 |
PNP output | EX-L291-P | EX-L221-P | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||
Sensing range | 4 m 13.123 ft (Note 2) | 45 to 300 mm 1.772 to 11.811 in (Note 3) | |
Emission spot size (Typical) | Approx. 6 × 4 mm 0.236 × 0.157 in (vertical x horizontal) (at a sensing distance of 1 m) (Note 4) |
ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) |
|
Sensing object | Opaque translucent object of ø25 mm ø0.984 in or more | Opaque, translucent or transparent object (Note 7) | |
Minimum sensing object (Typical) (Note 5) |
– | Gold wire of ø0.01 mm ø0.0004 in | |
Hysteresis | 20 % or less of operation distance | ||
Repeatability | Perpendicular to sensing axis: 0.2 mm 0.0080 in or less | ||
Repeatability (Typical) (perpendicular to sensing axis) (Note 5) |
– | 0.02 mm 0.0008 in or less (at 100 to 200 mm sensing distance) |
|
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Current consumption | 15 mA or less | ||
Output | <NPN output type> NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 26.4 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current) 1 V or less (at 16 mA sink current) <PNP output type> |
||
Output operation | Light-ON / Dark-ON selectable by the output operation switching input | ||
Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) | ||
Response time | 0.5 ms or less | ||
Operation indicator | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
||
Automatic interference prevention function | Incorporated (Two sensors can be mounted close together.) | ||
Sensitivity adjuster | Continuously variable adjuster | ||
Protection | IP67 (IEC) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition), Storage: -30 to +70 ℃ -22 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | ||
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | ||
Emitting element | Red semiconductor laser Class 1 (IEC / JIS / FDA / GB) (Note 6) (Maximum output: EX-L291□ 0.5 mW, EX-L221□ 2 mW, Peak emission wavelength: 655 nm 0.026 mil) |
||
Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | ||
Cable | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | ||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | ||
Weight | Net weight: 45 g approx., Gross weight: 60 g approx. | ||
Accessory | RF-330 (Reflector): 1 pc. MS-EXL2-3 (Mounting plate): 1 pc. |
MS-EXL2-3 (Mounting plate): 1 pc. |
Notes :
Column 1 |
---|
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉ |
---|---|
2) | The sensing range is the value for RF-330 reflector. The sensing range represents the actual sensing range of the sensor. The sensing ranges itemized in ” A ” of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. *1 Refer to “OPTIONS” for the polarizing filter PF-EXL2-1 and the reflector RF-210. *2 When positioning the reflector nearby, the angular characteristic become more narrow. Adjust the angle of a sensor or reflector. |
3) | The sensing range is specified for white non-glossy papar (100 × 100 mm 3.937 × 3.937 in) as the object. |
4) | In the case sensing distance is 4 m 13.123 ft, the emission spot size is H 18 × W 10 mm H 0.709 × W 0.394 in (visual reference value). |
5) | Typical values when the sensitivity adjuster is optimally adjusted. |
6) | This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
7) | Make sure to confirm detection with an actual sensor before use. |
Type | Convergent reflective | ||
---|---|---|---|
Spot | Line spot | ||
Model No. |
NPN output | EX-L261 | EX-L262 |
PNP output | EX-L261-P | EX-L262-P | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||
Sensing range | 20 to 50 mm 0.787 to 1.969 in (Convergent point: 22 mm 0.866 in) (Note 2) |
20 to 70 mm 0.787 to 2.756 in (Convergent point: 22 mm 0.866 in) (Note 2) |
|
Emission spot size (Typical) |
ø1mm 0.039 in or less (at a sensing distance of 50 mm) |
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical × horizontal) (at a sensing distance of 50 mm) |
|
Sensing object | Opaque, translucent or transparent object (Note 5) | ||
Minimum sensing object (Typical) (Note 3) |
Gold wire of ø0.01 mm ø0.0004 in | – | |
Hysteresis | 20 % or less of operation distance | ||
Repeatability | Perpendicular to sensing axis: 0.2 mm 0.0080 in or less | ||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Current consumption | 15 mA or less | ||
Output | <NPN output type> NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 26.4 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current) 1 V or less (at 16 mA sink current) <PNP output type> |
||
Output operation | Light-ON / Dark-ON selectable by the output operation switching input | ||
Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) | ||
Response time | 0.5 ms or less | ||
Operation indicator | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
||
Automatic interference prevention function | Incorporated (Two sensors can be mounted close together.) | ||
Sensitivity adjuster | Continuously variable adjuster | ||
Protection | IP67(IEC) | ||
Ambient temperature | -10 to +55℃ +14 to +131℉(No dew condensation or icing allowed), Storage: –30 to +70℃ –22 to +158℉ |
||
Ambient humidity | 35 to 85%RH , Storage:35 to 85%RH | ||
Emitting element | Red semiconductor laser Class 1 (IEC / JIS / FDA / GB) (Note 4) (Maximum output: EX-L261□ 1 mW, EX-L262□ 1.3 mW, Peak emission wavelength: 655 nm 0.026 mil) |
||
Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | ||
Cable | 0.15 mm2 4-core cabtyre cable, 2 m 6.562 ft long | ||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable | ||
Weight | Net weight: 45 g approx., Gross weight: 60 g approx. | ||
Accessory | MS-EXL2-3 (Mounting plate): 1 pc. |
Notes :
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉ |
---|---|
2) | The sensing range is specified for white non-glossy papar (100 × 100 mm 3.937 × 3.937 in) as the object. |
3) | Typical values when the sensitivity adjuster is optimally adjusted. |
4) | This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
5) | Make sure to confirm detection with an actual sensor before use. |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)