DT50-2B215252 Mid range distance sensors – SICK Sensor

USD $ 1,045.44

SKU: SICK 1065661

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1065661
Distance Sensor Model: DT50-2B215252
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 10 V … 30 V 1) 2)
Ripple ≤ 5 Vpp 3)
Power consumption ≤ 1.7 W 4)
Initialization time ≤ 300 ms
Warm-up time ≤ 15 min
Housing material Metal (zinc diecast)
Window material Plastic (PMMA)
Connection type Male connector, M12, 5-pin
Indication 3 x LED, LC display
Weight 235 g
Dimensions (W x H x D) 36.2 mm x 63 mm x 58.6 mm
Enclosure rating IP65

IP67

Protection class III
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) When using IO-Link output Vs > 18 V. When using analog output Vs > 13 V.
  • 3) May not fall short of or exceed VS tolerances.
  • 4) Without load, at ≥ 0 °C.

Performance

Measuring range 200 mm … 30,000 mm, 90 % remission 1) 2)

200 mm … 17,000 mm, 18 % remission

200 mm … 10,000 mm, 6 % remission

Target Natural objects
Resolution 0.1 mm
Repeatability ≥ 0.5 mm 2) 3) 4)
Accuracy ± 7 mm 4)
Response time 0.83 ms … 75 ms, 0.83 ms / 3.33 ms / 8.33 ms / 25 ms / 75 ms 5) 6)
Switching frequency 1,000 Hz/250 Hz/100 Hz/33 Hz/11 Hz 5) 6)
Output time 0.33 ms/1.33 ms/3.33 ms/10 ms/30 ms 5) 7)
Light source Laser, red 8)
visible red light
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 10 mm x 10 mm (at 10 m)
Additional function Set speed: Super Fast … Super Slow, teach-in, scaling and inversion of analog output, Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated, Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB), teach-in, scaling and inversion of digital output, Multifunctional input: laser off / external teach / deactivated, reset to factory default, Shape comparison: based on the distance measured over a period of time, Hold measurement value, switch-off or lock display, easy teach option
Average laser service life (at 25 °C) 100,000 h
  • 1) For speed setting Slow.
  • 2) See repeatability characteristic lines.
  • 3) Equivalent to 1 σ.
  • 4) 6 % … 90 % remission.
  • 5) Depending on the set speed: Super Fast … Super Slow.
  • 6) Lateral entry of the object into the measuring range.
  • 7) Continuous change of distance in measuring range.
  • 8) Wavelength: 658 nm; max. output: 250 mW; pulse duration: 3 ns; duty cycle: 1/250.

Interfaces

IO-Link ✔ , IO-Link V1.1, COM3 (230,4 kBaud)
Function Process data, parameterization, diagnosis, data storage
Digital output
Number 1 … 2 1) 2) 3)
Type Push-pull: PNP/NPN
Function Complementary digital outputs (Q, Ǭ)
Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Current output / voltage output
Function Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated
Current 4 mA … 20 mA, ≤ 450 Ω
Voltage 0 V … 10 V, ≥ 50 Ω
Resolution 16 bit
Multifunctional input (MF) 1 x 4)
Hysteresis 0 mm … 29,950 mm
  • 1) Output Q short-circuit protected.
  • 2) Voltage drop < 3 V.
  • 3) Max. total output current < 200 mA.
  • 4) Response time ≤ 60 ms.

Ambient data

Ambient temperature, operation –40 °C … +65 °C, Uv ≤ 24 V

–30 °C … +80 °C, operation with 2 cooling plates

–30 °C … +140 °C, operation with 2 cooling plates and protection filter

Ambient temperature, storage –40 °C … +75 °C
Typ. Ambient light immunity 40,000 lx
Vibration resistance EN 60068-2-6, EN 60068-2-64
Shock resistance EN 60068-2-27