Contact Us:
sales@inosaki.com

D4N – Switches with Two Contacts – Roller lever (Metal Lever,Resin Roller) – Omron Safety Limit Switches

$ 17.48$ 21.85

SKU N/A Category

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15

 

Certified Standards

Certification body Standards File No.
TÜV SÜD EN60947-5-1
(certified direct opening)
*1
UL *2 UL508, CSA C22.2 No.14 E76675
CQC (CCC) *3 GB/T14048.5 *1

 

*1. Consult your OMRON representative for details.
*2. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*3. Ask your OMRON representative for information on certified models.

 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T14048.5)

Item AC-15 DC-13
Rated operating current (Ie) 3 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3

 

Q300

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC 2.5 A 0.55 0.55 69 69
250 VDC 0.27 0.27

 

Characteristics

Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 15,000,000 operations min. *5
Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 1 to 500 mm/s (D4N-1120)
Operating frequency 30 operations/minute max.
Contact resistance 25 mΩ max.
Minimum applicable load *4 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 300 V
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of same polarity 2.5 kV
Between terminals of different
polarity
4 kV
Between each terminal and non-
current carrying metallic parts
6 kV
Insulation resistance 100 MΩ min.
Contact gap Snap-action: 2 × 0.5 mm min.
Slow-action: 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 10 A (EN60947-5-1)
Ambient operating temperature -30 to 70°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-6120)

 

 

Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.
Doing so may result in roughening of the contact surface and contact reliability may be lost.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust or water penetration, do not use the D4N in places where foreign material such as dust, dirt, oil,
water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
possible with the actual load beforehand.
*5. The mechanical durability of fork lever lock models is 10,000,000 operations min.

 

Model D4N-1122, D4N-1222, D4N-2122, D4N-2222, D4N-4122, D4N-4222

Additional information

Weight N/A
Model

, , , , ,

Related Products

PRL12-4DP
IDS Camera_uEye+_CP_1
PEPPERLFUCHS_Inductive Sensors_NBB10-30GM50-WS_1
Festo_Vacuum generators_VN-05-H-T2-PI2-VI2-RI2_526102
SIMATIC_ET_200SP_IM 155-6PN 2 HF
SCHNEIDER_TeSys Deca Time Delay Auxiliary Contact Module, Energize Delay,1-30 Seconds,Screw Clamp Terminals
Select your currency