D4N – Switches with Two Contacts – Roller lever (Resin Lever, Resin Roller) – Omron Safety Limit Switches
USD $ 15.62 – USD $ 20.02
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certified Standards
Certification body | Standards | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) |
*1 |
UL *2 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) *3 | GB/T14048.5 | *1 |
*1. Consult your OMRON representative for details.
*2. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*3. Ask your OMRON representative for information on certified models.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T14048.5)
Item | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
Q300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 2.5 A | 0.55 | 0.55 | 69 | 69 |
250 VDC | 0.27 | 0.27 |
Characteristics
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 15,000,000 operations min. *5 |
Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) |
|
Operating speed | 1 to 500 mm/s (D4N-1120) | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity | 2.5 kV |
Between terminals of different polarity |
4 kV | |
Between each terminal and non- current carrying metallic parts |
6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | Snap-action: 2 × 0.5 mm min. Slow-action: 2 × 2 mm min. |
|
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 82 g (D4N-1120) Approx. 99 g (D4N-6120) |
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.
Doing so may result in roughening of the contact surface and contact reliability may be lost.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust or water penetration, do not use the D4N in places where foreign material such as dust, dirt, oil,
water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
possible with the actual load beforehand.
*5. The mechanical durability of fork lever lock models is 10,000,000 operations min.
Model | D4N-1120, D4N-1220, D4N-2120, D4N-2220, D4N-4120, D4N-4220 |
---|
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details