CS84-P3612 Color Sensors – SICK Sensor
USD $ 915.42
SKU: SICK 1028227
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1028227
Color Sensor Model: CS84-P3612
OEM Spec Ref
Features
Dimensions (W x H x D) | 30.4 mm x 80 mm x 53 mm |
Sensing distance | 60 mm 1) |
Sensing distance tolerance | ± 9 mm |
Housing design (light emission) | Rectangular |
Light source | LED, RGB 2) |
Wave length | 640 nm, 525 nm, 470 nm |
Light spot size | 13 mm x 13 mm |
Adjustment | Teach-in button |
Teach-in mode | Static 1-point teach-in |
- 1) From front edge of lens.
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | < 120 mA 3) |
Switching frequency | 0.5 kHz 4)
1 kHz 3.5 kHz Adjustable |
Response time | 1,000 µs, 500 µs, 145 µs 5) |
Switching output | PNP |
Switching output (voltage) | PNP: HIGH = VS– ≤ 2 V / LOW approx. 0 V |
Output (channel) | 4 colors |
Output current Imax. | < 100 mA 6) |
Input, teach-in (ET) | PNP
Teach: U = 10 V … < UV Run: U < 2 V |
Input, blanking input (AT) | PNP
Blanked: U > 10 V … < Uv Free-running: U < 2 V 7) |
Retention time (ET) | 25 ms, non-volatile memory |
Time delay | Deactivation delay 20 ms, shiftable |
Connection type | Male connector M12, 8-pin |
Protection class | II 8) |
Circuit protection | UV connections, reverse polarity protected
Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 400 g |
Housing material | Metal, zinc diecast |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1.
- 5) Signal transit time with resistive load.
- 6) Consumption count Q1 / Q2.
- 7) AT > 200 µs.
- 8) Reference voltage DC 32 V.