Limit Switches OsiSense XC Standard – XCMD – Schneider Limit Switches

USD $ 37.18USD $ 67.10

SKU: N/A

Specifications

Main
Part Number XCMD2102L1 XCMD2117M12 XCMD2102C12 XCMD2102L5
Range of product Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Series name Standard format Standard format Standard format Standard format
Product or component type Limit switch Limit switch Limit switch Limit switch
Device short name XCMD XCMD XCMD XCMD
Sensor design Miniature Miniature Miniature Miniature
body type Fixed Plug-in body Plug-in body Fixed
Head type Plunger head Rotary head Plunger head Plunger head
Material Metal Metal Metal Metal
Body material Zamak Zamak Zamak Zamak
Head material Zamak Zamak Zamak Zamak
Fixing mode By the body By the body By the body By the body
Movement of operating head Linear Rotary Linear Linear
Type of operator Spring return roller plunger metal Spring return roller lever metal ball bearing mounted Spring return roller plunger metal Spring return roller plunger metal
Type of approach Lateral approach, 2 directions Lateral approach, 2 directions Lateral approach, 2 directions Lateral approach, 2 directions
Number of poles 2 1 2 2
Contacts type and composition 1 NC + 1 NO 1 C/O 1 NC + 1 NO 1 NC + 1 NO
Contact operation Snap action Snap action Snap action Snap action
Complementary
Tracks 24/31 mm
Switch actuation By 30° cam By 30° cam By 30° cam By 30° cam
Electrical connection Removable cable connector Male connector M12, 4 pins Male connector M12, 5 pins Removable cable connector
Cable length 1 m 5 m
Contacts insulation form Za Zb
Cable composition 5 x 0.75 mm² 5 x 0.75 mm²
wire insulation material PvR PvR
Contacts insulation form Zb Zb
Positive opening With Without With With
Positive opening minimum force 35 N 35 N 35 N
Minimum force for tripping 7 N 0.1 N 7 N 7 N
Maximum actuation speed 0.5 m/s 1.5 m/s 0.5 m/s 0.5 m/s
Contact code designation B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A 1.5 A at 240 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A 0.22 A at 50 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A 0.1 A at 250 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A 3 A at 50 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 3:00 AM 4:00 AM
[Ui] rated insulation voltage 300 V (pollution degree 3) conforming to UL 508 250 V (pollution degree 3) conforming to IEC 60947-5-1 60 V (pollution degree 3) conforming to IEC 60947-5-1 300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1 400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14 300 V (pollution degree 3) conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 mOhm conforming to IEC 60255-7 category 3 25 mOhm conforming to IEC 60255-7 category 3 25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 60664 2.5 kV conforming to IEC 60664 0.8 kV conforming to IEC 60664 4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1 2.5 kV conforming to IEC 60947-1 0.8 kV conforming to IEC 60947-1 4 kV conforming to IEC 60947-1
Short-circuit protection 6 A cartridge fuse, type gG 4 A cartridge fuse, type gG 4 A cartridge fuse, type gG 6 A cartridge fuse, type gG
Electrical durability 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 10000000 cycles 10000000 cycles 10000000 cycles 10000000 cycles
Width 30 mm 30 mm 30 mm 30 mm
Height 50 mm 50 mm 50 mm 50 mm
Depth 16 mm 16 mm 16 mm 16 mm
Product weight 0.185 kg 0.125 kg 0.09 kg
Environment
Shock resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforming to IEC 60529
IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforming to IEC 60529
IP68 conforming to IEC 60529 IP68 conforming to IEC 60529 IP68 conforming to IEC 60529 IP68 conforming to IEC 60529
IK degree of protection IK06 conforming to EN 62262 IK06 conforming to EN 62262 IK06 conforming to EN 62262 IK06 conforming to EN 62262
Overvoltage category Class I conforming to IEC 61140 Class I
Class I conforming to NF C 20-030
Electrical shock protection class Class I conforming to IEC 61140 Class I conforming to IEC 61140
Class I conforming to NF C 20-030 Class I conforming to NF C 20-030
Ambient air temperature for operation -25…70 °C -25…70 °C -25…70 °C -25…70 °C
Ambient air temperature for storage -40…70 °C -40…70 °C -40…70 °C
Protective treatment TC TC TC
Product certifications CCC CSA CSA CSA
CSA CCC UL UL
UL UL CCC
Standards EN/IEC 60204-1 UL 508 CSA C22.2 No 14 EN 60947-5-1
UL 508 EN/IEC 60204-1 EN/IEC 60947-5-1 UL 508
EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60204-1 IEC 60947-5-1
CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 1.621 cm 3.5 cm 1.7 cm 3.0 cm
Package 1 Width 16.107 cm 9.5 cm 7.1 cm 20.0 cm
Package 1 Length 17.712 cm 5.3 cm 5.2 cm 20.0 cm
Package 1 Weight 173.7 g 132 g 92.0 g 506.0 g
Unit Type of Package 2 S02 S02 P06
Number of Units in Package 2 30 50 160
Package 2 Height 15 cm 15.0 cm 60.0 cm
Package 2 Width 30 cm 30.0 cm 80.0 cm
Package 2 Length 40 cm 40.0 cm 60.0 cm
Package 2 Weight 5.739 kg 5.105 kg 93.884 kg
Unit Type of Package 3 P06 PAL S03
Number of Units in Package 3 480 800 20
Package 3 Height 80 cm 60.0 cm 30.0 cm
Package 3 Width 80 cm 80.0 cm 30.0 cm
Package 3 Length 60 cm 800.0 cm 40.0 cm
Package 3 Weight 97.86 kg 1017.6 kg 10.826 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

 

 

 

Main
Part Number XCMD2102L3 XCMD2115L1 XCMD2102L2 XCMD2110L1
Range of product Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Series name Standard format Standard format Standard format Standard format
Product or component type Limit switch Limit switch Limit switch Limit switch
device short name XCMD XCMD XCMD XCMD
Sensor design Miniature Miniature Miniature Miniature
body type Fixed Fixed Fixed Fixed
Head type Plunger head Rotary head Plunger head Plunger head
Material Metal Metal Metal Metal
Body material Zamak Zamak Zamak Zamak
Head material Zamak Zamak Zamak Zamak
Fixing mode By the body By the body By the body By the body
Movement of operating head Linear Rotary Linear Linear
Type of operator Spring return roller plunger metal Spring return roller lever thermoplastic Spring return roller plunger metal Spring return plunger metal
Type of approach Lateral approach, 2 directions Lateral approach, 2 directions Lateral approach, 2 directions Vertical approach, 1 direction
Number of poles 2 2 2 2
Contacts type and composition 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
Contact operation Snap action Snap action Snap action Snap action
Complementary
Switch actuation By 30° cam By 30° cam By 30° cam On end
Tracks 24/31 mm
Electrical connection Removable cable connector Removable cable connector Removable cable connector Removable cable connector
Cable length 3 m 1 m 2 m 1 m
Cable composition 5 x 0.75 mm² 5 x 0.75 mm² 5 x 0.75 mm² 5 x 0.75 mm²
wire insulation material PvR PvR PvR PvR
Contacts insulation form Zb Zb Zb Zb
Positive opening With With With With
Positive opening minimum force 35 N 0.5 N 35 N 42.5 N
Minimum force for tripping 7 N 0.1 N 7 N 8.5 N
Minimum actuation speed 0.01 m/min
Maximum actuation speed 0.5 m/s 1.5 m/s 0.5 m/s 0.5 m/s
Contact code designation B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage 300 V (pollution degree 3) conforming to UL 508 300 V (pollution degree 3) conforming to UL 508 300 V (pollution degree 3) conforming to UL 508 300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1 400 V (pollution degree 3) conforming to IEC 60947-5-1 400 V (pollution degree 3) conforming to IEC 60947-5-1 400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14 300 V (pollution degree 3) conforming to CSA C22.2 No 14 300 V (pollution degree 3) conforming to CSA C22.2 No 14 300 V (pollution degree 3) conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 mOhm conforming to IEC 60255-7 category 3 25 mOhm conforming to IEC 60255-7 category 3 25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 60664 4 kV conforming to IEC 60664 4 kV conforming to IEC 60664 4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60947-1
Short-circuit protection 6 A cartridge fuse, type gG 6 A cartridge fuse, type gG 6 A cartridge fuse, type gG 6 A cartridge fuse, type gG
Electrical durability 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 10000000 cycles 10000000 cycles 10000000 cycles 10000000 cycles
Width 30 mm 30 mm 30 mm 30 mm
Height 50 mm 50 mm 50 mm 50 mm
Depth 16 mm 16 mm 16 mm 16 mm
Product weight 0.22 kg 0.185 kg 0.18 kg
Environment
Shock resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforming to IEC 60529
IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforming to IEC 60529
IP68 conforming to IEC 60529 IP68 conforming to IEC 60529 IP68 conforming to IEC 60529 IP68 conforming to IEC 60529
IK degree of protection IK06 conforming to EN 62262 IK06 conforming to EN 62262 IK06 conforming to EN 50102 IK06 conforming to EN 62262
Overvoltage category Class I Class I conforming to IEC 61140 Class I conforming to IEC 61140 Class I conforming to IEC 61140
Class I conforming to NF C 20-030 Class I conforming to NF C 20-030 Class I conforming to NF C 20-030
Ambient air temperature for operation -25…70 °C -25…70 °C -25…70 °C -25…70 °C
-40…70 °C -40…70 °C -40…70 °C
TC TH TC
Product certifications UL CCC CCC CSA
CSA UL UL UL
CSA CSA CCC
Standards EN 60947-5-1 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508
IEC 60947-5-1 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60204-1
CSA C22.2 No 14 UL 508 UL 508 CSA C22.2 No 14
UL 508 EN/IEC 60204-1 CSA C22.2 No 14 EN/IEC 60947-5-1
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 2.5 cm 1.867 cm 3.0 cm 2.54 cm
Package 1 Width 20.0 cm 16.12 cm 12.5 cm 17.78 cm
Package 1 Length 20.0 cm 19.921 cm 12.5 cm 17.78 cm
Package 1 Weight 334.0 g 207.3 g 252.0 g 163.29 g
Unit Type of Package 2 PAL S03 S03 S02
Number of Units in Package 2 240 50 40 30
Package 2 Height 60.0 cm 30 cm 30.0 cm 15 cm
Package 2 Width 80.0 cm 30 cm 30.0 cm 30 cm
Package 2 Length 240.0 cm 40 cm 40.0 cm 40 cm
Package 2 Weight 82.08 kg 11.062 kg 10.716 kg 5.451 kg
Unit Type of Package 3 S03 P06
Number of Units in Package 3 30 400
Package 3 Height 30.0 cm 80 cm
Package 3 Width 30.0 cm 80 cm
Package 3 Length 40.0 cm 60 cm
Package 3 Weight 11.053 kg 92.1 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

 

 

 

Main information
Part Number XCMD2111L1 XCMD2116L1 XCMD2117L1 XCMD2145L1
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type Standard type
product type Limit switch Limit switch Limit switch Limit switch
product short name XCMD XCMD XCMD XCMD
sensor design Miniature Miniature Miniature Miniature
ontology type Fixed Fixed Fixed Fixed
Control head type Direct acting head Swivel head Swivel head Swivel head
Material Metal Metal Metal Metal
body material Zamak Zamak Zamak Zamak
head material Zamak Zamak Zamak Zamak
fixed mode By ontology By ontology By ontology By ontology
Operation head movement Linear To rotate To rotate To rotate
Operating head type Spring return direct acting metal with rubber cover Spring Return Roller Rocker Metal Spring Return Roller Rocker Metal Ball Bearing Mounting Spring Return Roller Rocker Thermoplastic Variable Length
method type Vertical movement, one-way Lateral movement, 2-way Lateral movement, 2-way Lateral movement, 2-way
number of poles 2 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary Momentary Momentary
Additional information
track 24/31 mm 24/31 mm
switch trigger The end 30° lip 30° lip 30° lip
Electrical connections Detachable cable connector Detachable cable connector Detachable cable connector Detachable cable connector
cable length 1 m 1 m 1 m 1 m
Cable composition 5 x 0.75 mm² 5 x 0.75 mm² 5 x 0.75 mm² 5 x 0.75 mm²
wire insulation PvR PvR PvR PvR
Type of contact wire insulation Zb Zb Zb Zb
force open Have Have Have Have
force open minimum force 42.5N 0.5N 0.5N 0.5N
Minimum trip force 8.5N 0.1N 0.1N 0.1N
minimum braking speed 0.01 m/min
operating speed 0.5 m/s 1.5 m/s 1.5 m/s 1.5 m/s
Contact wire regulation grade B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC-
13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated insulation voltage [Ui] 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508
400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1
300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14
Maximum resistance across terminals 25 mΩ conforming to IEC 60255-7 Safety Class 3 25 mΩ conforming to IEC 60255-7 Safety Class 3 25 mΩ conforming to IEC 60255-7 Safety Class 3 25 mΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 4 kV according to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664
4 kV according to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1
Short circuit protection 6 A fuse fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13,
24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C
Mechanical life 10000000 times 10000000 times 10000000 times 10000000 times
width 30 mm 30 mm 30 mm 30 mm
high 50 mm 50 mm 50 mm 50 mm
depth 16 mm 16 mm 16 mm 16 mm
product weight 0.18 kg 0.225 kg 0.22kg 0.23 kg
Environment
impact resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Anti-vibration 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class IP66 conforms to screwed IP66 conforms to screwed IP66 conforms to screwed IP66 conforms to screwed
IP67 conforms to screwed IP67 conforms to screwed IP67 conforms to screwed IP67 conforms to screwed
IP68 conforms to screwed IP68 conforms to screwed IP68 conforms to screwed IP68 conforms to screwed
IK protection class IK06 conforms to EN 62262 IK06 conforms to EN 62262 IK06 conforms to EN 62262 IK06 conforms to EN 62262
Type of overvoltage Class I conforms to IEC 61140 Class I conforms to IEC 61140 Class I conforms to IEC 61140 Class I conforms to IEC 61140
Class I conforms to NF C 20-030 Class I conforms to NF C 20-030 Class I conforms to NF C 20-030 Class I conforms to NF C 20-030
operating temperature -25…70°C -25…70°C -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70°C -40…70°C -40…70°C
Protective treatment TC TC TC TC
certified product CSA UL CSA CCC
CCC CCC CCC CSA
UL CSA UL UL
Standards compliant EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14 CSA C22.2 No 14
CSA C22.2 No 14 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-1
UL 508 EN/IEC 60204-1 UL 508 UL 508
EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60947-5-1
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 2.0cm 4.414 cm 2.5cm 4.0cm
Package 1 Width 18.0cm 17.199 cm 13.0cm 16.0cm
Package 1 Length 20.0cm 18.639 cm 13.0cm 10.5cm
Package 1 Weight 172.0g 201.0g 211.0g 218.0g
Unit Type of Package 2 S02 S03 PAL PAL
Number of Units in Package 2 30 45 400 400
Package 2 Height 15cm 30cm 60.0cm 60.0cm
Package 2 Width 30cm 30cm 80.0cm 80.0cm
Package 2 Length 40cm 40cm 400.0cm 400.0cm
Package 2 Weight 5.685kg 10.551kg 86.0 kg 88.0 kg
Unit Type of Package 3 P06 P06 S03 S03
Number of Units in Package 3 480 360 50 50
Package 3 Height 75cm 75cm 30.0cm 30.0cm
Package 3 Width 60cm 60cm 30.0cm 30.0cm
Package 3 Length 80cm 80cm 40.0cm 40.0cm
Package 3 Weight 99kg 89kg 11.282kg 11.484 kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

 

Main information
Part Number XCMD21F0L1 XCMD21F2L1 XCMD21G1L1
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type
product type Limit switch Limit switch Limit switch
product short name XCMD XCMD XCMD
sensor design Miniature Miniature Miniature
ontology type Fixed Fixed Fixed
Control head type M12 direct acting head M12 direct acting head M16 direct acting head
Material Metal Metal Metal
body material Zamak Zamak Zamak
head material Zamak Zamak Zamak
fixed mode Head fixation Head fixation Head fixation
Operation head movement Linear Linear Linear
Operating head type Spring return direct acting metal Spring Return, Roller Direct Action Metal Spring return direct acting metal with rubber cover
method type Vertical movement, one-way Lateral movement, 2-way Vertical movement, one-way
number of poles 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary Momentary
Additional information
switch trigger The end 30° lip The end
Electrical connections Detachable cable connector Detachable cable connector Detachable cable connector
cable length 1 m 1 m 1 m
Cable composition 5 x 0.75 mm² 5 x 0.75 mm² 5 x 0.75 mm²
wire insulation PvR PvR PvR
Type of contact wire insulation Zb Zb Zb
force open Have Have Have
force open minimum force 42.5 N 35N 42.5N
Minimum trip force 8.5N 7 N 8.5N
minimum braking speed 0.01 m/min 0.01 m/min
operating speed 0.5 m/s 10cm/s 0.5 m/s
Contact wire regulation grade B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC-
13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated insulation voltage [Ui] 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508
400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1
300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14
Maximum resistance across terminals 25 mΩ conforming to IEC 60255-7 Safety Class 3 25 mΩ conforming to IEC 60255-7 Safety Class 3 25 mΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 4 kV according to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664
4 kV according to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1
Short circuit protection 6 A fuse fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13,
24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C
Mechanical life 10000000 times 10000000 times 10000000 times
width 30 mm 30 mm 30 mm
high 50 mm 50 mm 50 mm
depth 16 mm 16 mm 16 mm
product weight 0.195 kg 0.205kg 0.22kg
Environment
impact resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Anti-vibration 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class IP66 conforms to screwed IP66 conforms to screwed IP66 conforms to screwed
IP67 conforms to screwed IP67 conforms to screwed IP67 conforms to screwed
IP68 conforms to screwed IP68 conforms to screwed IP68 conforms to screwed
IK protection class IK06 conforms to EN 62262 IK06 conforms to EN 62262 IK06 conforms to EN 62262
Type of overvoltage Class I conforms to IEC 61140 Class I conforms to IEC 61140 Class I conforms to IEC 61140
Class I conforms to NF C 20-030 Class I conforms to NF C 20-030 Class I conforms to NF C 20-030
operating temperature -25…70°C -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70°C -40…70°C
Protective treatment TC TC TC
certified product CCC CSA CCC
CSA UL CSA
UL CCC UL
Standards compliant UL 508 UL 508 EN/IEC 60204-1
EN/IEC 60204-1 EN/IEC 60204-1 EN/IEC 60947-5-1
EN/IEC 60947-5-1 EN/IEC 60947-5-1 CSA C22.2 No 14
CSA C22.2 No 14 CSA C22.2 No 14 UL 508
Packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 1.6cm 1.6cm 2.0cm
Package 1 Width 15.0cm 16.0cm 12.5cm
Package 1 Length 13.0cm 14.0cm 12.0cm
Package 1 Weight 186.0g 193.0g 210.0g
Unit Type of Package 2 PAL PAL PAL
Number of Units in Package 2 440 440 400
Package 2 Height 60.0cm 60.0cm 60.0cm
Package 2 Width 80.0cm 80.0cm 80.0cm
Package 2 Length 440.0 cm 440.0 cm 400.0cm
Package 2 Weight 94.6 kg 94.6 kg 86.0 kg
Unit Type of Package 3 S03 S03 S03
Number of Units in Package 3 55 55 50
Package 3 Height 30.0cm 30.0cm 30.0cm
Package 3 Width 30.0cm 30.0cm 30.0cm
Package 3 Length 40.0cm 40.0cm 40.0cm
Package 3 Weight 10.788 kg 11.208 kg 10.988kg
Contract warranty
Warranty 18 months 18 months 18 months
Weight N/A
Dimensions N/A
Model

, , , , , , , , , , , , , ,