VT12-2P110S01 Cylindrical Photoelectric Sensors – SICK Sensor

USD $ 126.50

SKU: SICK 6034337

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:6034337
Photoelectric Sensor Model:VT12-2P110S01
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Energetic
Dimensions (W x H x D) 12 mm x 12 mm x 54.5 mm
Housing design (light emission) Cylindrical
Housing length 54.5 mm
Thread diameter (housing) Round connector M12 x 1
Sensing range max. 0 mm … 115 mm 1)
Sensing range 2 mm … 100 mm
Focus Approx. 11.4°
Type of light Infrared light
Light source LED 2)
Light spot size (distance) Ø 20 mm (100 mm)
Angle of dispersion Approx. 11.4°
Wave length 880 nm
Adjustment None
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 20 mA 3)
Switching output PNP
Switching mode Light switching
Output current Imax. ≤ 100 mA 3)
Response time ≤ 1.25 ms 4)
Switching frequency 400 Hz 5)
Connection type Cable, 3-wire, 4 m 6)
Cable material PUR
Conductor cross-section 0.14 mm²
Cable diameter Ø 3.75 mm
Circuit protection 7)

8)

9)

10)

Protection class III
Weight 54 g
Special device
Housing material Metal, Nickel-plated brass/PA
Optics material Plastic, PMMA
Enclosure rating IP67
Ambient operating temperature –25 °C … +70 °C
Ambient temperature, storage –25 °C … +70 °C
UL File No. E175606
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) Do not bend below 0 °C.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) C = interference suppression.
  • 10) D = outputs overcurrent and short-circuit protected.