VS/VE18-4P3140V Cylindrical Photoelectric Sensors – SICK Sensor

USD $ 166.98

SKU: SICK 6035499

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:6035499
Photoelectric Sensor Model:VS/VE18-4P3140V
OEM Spec Ref 

Features

Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 18 mm x 18 mm x 83 mm
Housing design (light emission) Cylindrical
Housing length 83 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0 m … 20 m
Sensing range 0 m … 18 m
Focus 2.5°
Type of light Infrared light
Light source LED 1)
Light spot size (distance) Ø 600 mm (15 m)
Angle of dispersion 2.5°
Wave length 880 nm
Adjustment None
Special applications Hygienic and washdown zones
  • 1) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Power consumption, sender 35 mA 3)
Power consumption, receiver 40 mA 3)
Switching output PNP 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via L/D control cable
Signal voltage PNP HIGH/LOW Approx. VS – 2.0 V / 0 V
Output current Imax. ≤ 100 mA
Response time ≤ 2 ms 5)
Switching frequency 250 Hz 6)
Angle of reception
Attenuation along light beam ≥ 20 %
Connection type Male connector M12, 4-pin 7)
Circuit protection 8)

9)

10)

11)

Protection class III
Weight 240 g
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, Plan, PPS (Grilamid)
Enclosure rating IP67

IP68

IP69K 12)

Test input sender off TE to 0 V
Ambient operating temperature –25 °C … +80 °C 13)
Ambient temperature, storage –40 °C … +80 °C
UL File No. FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load, at VS 30 V DC.
  • 4) Control wire open: dark switching D.ON.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) With gold plated contact pins, PPS with FDA certificate.
  • 8) A = VS connections reverse-polarity protected.
  • 9) B = interference suppression.
  • 10) D = outputs overcurrent and short-circuit protected.
  • 11) D = inputs and output reverse-polarity protected.
  • 12) With correct mounted IP69K connector.
  • 13) +100 °C at max 15 minutes.

Safety-related parameters

MTTFD 415 years
DCavg 0 %