Contact Us:
sales@inosaki.com

VL18-4N3212 Cylindrical Photoelectric Sensors – SICK Sensor

$ 93.38

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6013540
Photoelectric Sensor Model:VL18-4N3212
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor
Dimensions (W x H x D) 18 mm x 18 mm x 63.6 mm
Housing design (light emission) Cylindrical
Housing length 63.6 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0.05 m … 3.7 m 1)
Sensing range 0.05 m … 3 m 1)
Focus Approx. 2.8°
Type of light Visible red light
Light source LED 2)
Light spot size (distance) Ø 150 mm (3 m)
Angle of dispersion Approx. 2.8°
Adjustment Potentiometer, 270° (Sensitivity)
  • 1) Reflector C110A.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Switching output NPN 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via L/D control cable
Output current Imax. ≤ 100 mA
Response time ≤ 2 ms 5)
Switching frequency 250 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm²
Cable diameter Ø 5 mm
Circuit protection 8)

9)

10)

11)

Protection class III
Weight 120 g
Polarisation filter
Housing material Metal, Nickel-plated brass
Optics material Plastic, PMMA
Enclosure rating IP67
Ambient operating temperature –25 °C … +70 °C
UL File No. NMFT2.E175606
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Control wire open: light switching L.ON.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) Do not bend below 0 °C.
  • 8) A = VS connections reverse-polarity protected.
  • 9) B = inputs and output reverse-polarity protected.
  • 10) C = interference suppression.
  • 11) D = outputs overcurrent and short-circuit protected.

 