UM30-215113 Ultrasonic sensors – SICK Sensor

USD $ 633.60

SKU: SICK 6036920

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6036920
Distance Sensor Model: UM30-215113
OEM Spec Ref

Mechanics/electronics

Supply voltage Vs DC 9 V … 30 V 1) 2)
Power consumption ≤ 2.4 W 3)
Initialization time < 300 ms
Design Cylindrical
Housing material Metal (nickel-plated brass, PBT)

Ultrasonic transducer: polyurethane foam, glass epoxy resin

Thread size M30 x 1.5
Connection type Male connector, M12, 5-pin
Indication LED display, 2 x LED
Weight 270 g
Sending axis Straight
Dimensions (W x H x D) 65 mm x 65 mm x 105 mm
Enclosure rating IP65 / IP67
Protection class III
  • 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
  • 2) 15 V … 30 V when using the analog voltage output.
  • 3) Without load.

Performance

Operating range, limiting range 600 mm … 6,000 mm, 8,000 mm
Target Natural objects
Resolution ≥ 0.18 mm
Repeatability ± 0.15 % 1)
Accuracy ± 1 % 2) 3)
Temperature compensation
Response time 240 ms 4)
Output time 60 ms
Ultrasonic frequency (typical) 80 kHz
Detection area (typical) See diagrams
Additional function Teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default
  • 1) In relation to the current measured value, minimum value ≥ resolution.
  • 2) Referring to current measurement value.
  • 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
  • 4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.

Interfaces

Analog output
Number 1
Type Current output / voltage output
Function Automatic selection of analog current or voltage output dependent on load
Current 4 mA … 20 mA, ≤ 500 Ω 1)
Voltage 0 V … 10 V, ≥ 100,000 Ω
Resolution 12 bit
Multifunctional input (MF) 1 x MF
  • 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.

Ambient data

Ambient temperature, operation –25 °C … +70 °C
Ambient temperature, storage –40 °C … +85 °C