UE410-MU3T5 – Flexi Classic – SICK Safety Controllers
USD $ 406.12
SKU: SICK 6026136
Part Number: 6026136
Non-contact safety switches: UE410-MU3T5
OEM Spec Ref
Features
Module | Main module |
Configuration method | Via rotary switch |
Safety-related parameters
Safety integrity level | SIL3 (IEC 61508) |
Category | Category 4 (EN ISO 13849) |
Performance level | PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 2.5 x 10-9 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Functions
Restart interlock | Manual / automatic (configurable) |
External device monitoring (EDM) | ✔ |
AND operation | ✔ |
OR operation | ✔ |
Bypass | ✔ |
Differentiation between man and material (muting) | ✔ |
Interfaces
Inputs | 4 safety inputs
4 switching inputs |
Number of muting sensors | 0 / 2 |
Outputs | 4 safety outputs
2 test outputs |
Delay time (outputs Q3/Q4) | 0 s … 5 s |
Connection type | Plug-in screw-type terminals |
Display elements | LEDs |
Electrical data
Protection class | III (EN 61140) |
Type of voltage supply | PELV or SELV 1) |
Supply voltage VS | 24 V DC (19.2 V DC … 30 V DC) |
Residual ripple | ≤ 10 % |
Power consumption | ≤ 3 W (DC) |
Switch-on time | ≤ 60 s |
Internal power consumption | ≤ 3 W (DC) |
1) The current of the power supply that powers the main unit must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Mechanical data
Dimensions (W x H x D) | 22.5 mm x 96.5 mm x 120.8 mm |
Weight | + 180 g |
|
|||||||
Ambient operating temperature | –25 °C … +55 °C | ||||||
Storage temperature | –25 °C … +70 °C | ||||||
Air humidity | ≤ 95 %, Non-condensing | ||||||
Climate conditions according to | EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) | ||||||
Electromagnetic compatibility (EMC) | Class A (EN 61000-6-2, EN 55011) | ||||||
Vibration resistance | 5 g RMS, 5 Hz … 500 Hz (EN 60068-2-64) |
Weight | 0.226 kg |
---|---|
Dimensions | 14 × 3.5 × 16.5 cm |