TRIO-PS-2G/1AC/24DC/20 – 2903151 – Phoenix Contact Power Supply

$ 294.40

SKU Phoenix Contact 2903151 Category

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my

Product Description

TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.

Dimensions

Width 68 mm
Height 130 mm
Depth 160 mm
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 50 mm / 50 mm

Ambient conditions

Degree of protection IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Ambient temperature (operation) -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)

Input data

Nominal input voltage range 100 V AC … 240 V AC
110 V DC … 250 V DC
Input voltage range 100 V AC … 240 V AC -15 % … +10 %
110 V DC … 250 V DC ±10 %
Dielectric strength maximum ≤ 300 V AC 15 s
AC frequency range 50 Hz … 60 Hz ±10 %
Discharge current to PE < 3.5 mA
Current consumption 5.6 A (100 V AC)
4.3 A (120 V AC)
2.4 A (230 V AC)
2.4 A (240 V AC)
Nominal power consumption 534.7 VA
Inrush current ≤ 20 A (typical)
Mains buffering time typ. 10 ms (120 V AC)
typ. 15 ms (230 V AC)
Input fuse 10 A (internal (device protection))
Recommended breaker for input protection 10 A … 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.98
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 24 V DC … 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 20 A
Dynamic Boost (IDyn.Boost) 30 A (5 s)
Derating > 60 °C … 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 30 V DC
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 3 % (Dynamic load change 10 % … 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 100 mVPP (with nominal values)
Output power 480 W
Typical response time < 1 s
Maximum power dissipation in no-load condition < 2.9 W (120 V AC)
< 2.8 W (230 V AC)
Power loss nominal load max. < 44.8 W (120 V AC)
< 36.8 W (230 V AC)

General

Article Number 2903151
Net weight 1.5 kg
Efficiency typ. 91.4 % (120 V AC)
typ. 92.9 % (230 V AC)
MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
> 1000000 h (40 °C)
> 480000 h (60 °C)
Insulation voltage input/output 3 kV AC (type test)
1.5 kV AC (routine test)
Degree of protection IP20
Protection class I (in closed control cabinet)
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm

Connection data, input

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 10 mm

Connection data, output

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 6 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 8
Stripping length 15 mm

Connection data for signaling

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard – Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
Standard – Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
Rail applications EN 50121-4

Conformance/approvals

UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1
Shipbuilding approval DNV GL

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Conducted noise emission EN 55016
EN 61000-6-3 (Class B)
Noise emission EN 55016
EN 61000-6-3 (Class B)
Electrostatic discharge EN 61000-4-2
Contact discharge 6 kV (Test Level 4)
Discharge in air 8 kV (Test Level 4)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz … 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1 GHz … 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (Test Level 4 – asymmetrical)
Output 2 kV (Test Level 3 – asymmetrical)
Signal 1 kV (Test Level 2 – asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 3 kV (Test Level 3 – symmetrical)
6 kV (Test Level 4 – asymmetrical)
Output 1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 1 – asymmetrical)
Signal 1 kV (Test Level 2 – asymmetrical)
Comments Criterion B
Conducted interference EN 61000-4-6
Frequency range 0.15 MHz … 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Additional information

Related Products

SICK_sensor_Inductive proximity sensor_IMF_IMF30_15BPPNC0S
Banner_QS30DQ _1
SIEMENS_SIMATIC S7-1500 - System Power Supply PS 25W 24 V DC
M12
IDS_Tripod adapter for USB 3 uEye SE &amp; GigE uEye_SE Rev
SICK_sensor_Photoelectric_sensor_W12-2 Laser_WL12GC-3P2472A00
Select your currency