Contact Us:
sales@inosaki.com

TeSys K – LP1K – 4-Poles Contactor – Schneider Contactors & Reversing Contactors

USD $ 52.44USD $ 55.89

Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number LP1K090085MD LP1K09008MD
Product Series TeSys K TeSys K
Product Series TeSys TeSys K
product type Contactor Contactor
product short name LP1K LP1K
Application field of contactor Applied to non-inductive or micro-inductive load, resistance furnace Applied to non-inductive or micro-inductive load, resistance furnace
use category AC-1 AC-1
number of poles 4P 4P
Loop contact type 2 NO + 2 NC 2 NO + 2 NC
Rated operating current [Ie] 20 A 50 °C) at <= 440 V AC AC-1 for power circuits
16 A 70 °C) at 690 V AC AC-1 for power circuits
20 A 50 °C) at <= 440 V AC AC-1 for power circuits
16 A 70 °C) at 690 V AC AC-1 for power circuits
Additional information
Control voltage limit Operating: 0.8…1.15 Uc 50 °C)
Release: 0.1…0.75 Uc 50 °C)
Operating: 0.8…1.15 Uc 50 °C)
Release: 0.1…0.75 Uc 50 °C)
Rated insulation voltage [Ui] Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA C22.2 No 14
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 8kV 8kV
Overvoltage category III III
installation method Printed circuit DIN rail installation
base plate installation
flame retardant V1 Conforms to UL 94
requirements2 Conforms to NF F 16-101
requirements2 Conforms to NF F 16-102
V1 Conforms to UL 94
requirements2 Conforms to NF F 16-101
requirements2 Conforms to NF F 16-102
Rated working voltage [Ue] Power circuit: 690 V AC 50/60 Hz Power circuit: 690 V AC 50/60 Hz
Conventional thermal current [Ith] 20 A at <50 °C for power circuits 20 A at <50 °C for power circuits
Rated making capacity [Irms] 110 A AC for power circuits according to NF C 63-110
110 A AC for power circuits according to IEC 60947
110 A AC for power circuits according to NF C 63-110
110 A AC for power circuits according to IEC 60947
Rated breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220…230 V conforming to IEC 60947
110 A at 380 …400 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220…230 V conforming to IEC 60947
110 A at 380 …400 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
Fuses for use with relays 25 A gG at <= 440 V for power circuits
25 A aM for power circuits
25 A gG at <= 440 V for power circuits
25 A aM for power circuits
average impedance 3 mΩ – Ith 20 A 50 Hz for power circuits 3 mΩ – Ith 20 A 50 Hz for power circuits
Surge power (W) 3W (20°C) 3W (20°C)
Holding power consumption(W) 3 W at 20 °C 3 W at 20 °C
action time 30…40 ms coil energizing and NO contact closing
10 ms coil discharging and NO opening
25…35 ms coil energizing and NC contact opening
15 ms coil de-energizing and NC closing
30…40 ms coil energizing and NO contact closing
10 ms coil discharging and NO opening
25…35 ms coil energizing and NC contact opening
15 ms coil de-energizing and NC closing
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 10 Mcycles 10 Mcycles
operating frequency 3600 times/hour 3600 times/hour
high 58 mm 58 mm
width 45 mm 45 mm
depth 57 mm 57 mm
Product Weight 0.225 kg 0.225 kg
environment
certified product UL
CSA
UKCA
UL
CSA
UKCA
operating temperature -25…50°C -25…50°C
storage environment temperature -50…80 °C -50…80 °C
working altitude 2000 meters without 2000 meters without
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 4.5cm 4.8cm
Package 1 Width 6.0cm 6.0cm
Package 1 Length 6.5cm 6.5cm
Package 1 Weight 236.0g 213.0g
Unit Type of Package 2 S02 S02
Number of Units in Package 2 40 40
Package 2 Height 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm
Package 2 Weight 9.673kg 8.909kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 75.0cm
Package 3 Width 80.0cm
Package 3 Length 60.0cm
Package 3 Weight 162.768kg
contract warranty
Warranty 18 months 18 months

[/fusion_table]

 