Specifications

Main
Part Number LRD3322C LRD3353C LRD3355C LRD3357C
Product Series TeSys
TeSys Deca
TeSys TeSys TeSys
product name TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
product type Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay
product short name LRD LRD LRD LRD
Relay application Motor protection Motor protection Motor protection Motor protection
The scope of products Compatible with LC1D40…D95 Compatible with LC1D40…D95 Compatible with LC1D40…D95 Compatible with LC1D40…D95
Relay setting range 17…25A 23…32A 30…40A 37…50A
Additional information
control type Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Current setting range 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits
Thermal release drag rating Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1
Trip threshold 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1
phase loss sensitivity 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5
Conventional thermal current [Ith] 5 A for signal circuits 5 A for signal circuits 5 A for signal circuits 5 A for signal circuits
installation method Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Wiring capacity Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Tightening torque Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
width 70 mm 70 mm 70 mm 70 mm
depth 109 mm 109 mm 109 mm 109 mm
Product Weight 0.51kg 0.51kg 0.51kg 0.51kg
environment
Standards compliant IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
UKCA
CE
CCC
UKCA
CE
CCC
UKCA
CE
CCC
UKCA
IP protection class IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
ambient temperature -20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
storage environment temperature -60…70°C -60…70°C -60…70°C -60…70°C
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1
flame retardant V1 complies with UL 94 V1 complies with UL 94 V1 complies with UL 94
Shock and vibration resistance Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Insulation properties 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 7.7cm 8.202 cm 7.907 cm 7.66cm
Package 1 Width 8.7cm 8.971 cm 8.853 cm 9.04 cm
Package 1 Length 12.3 cm 12.558 cm 12.628 cm 12.516 cm
Package 1 Weight 493g 491g 480g 480g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 9 9 9 9
Package 2 Height 15cm 15cm 15cm 15cm
Package 2 Width 30cm 30cm 30cm 30cm
Package 2 Length 40cm 40cm 40cm 40cm
Package 2 Weight 4.829 kg 4.77kg 4.77kg 4.731 kg
Unit Type of Package 3 P06 PAL PAL PAL
Number of Units in Package 3 144 144 144 144
Package 3 Height 75cm 75cm 75cm 75cm
Package 3 Width 60cm 60cm 60cm 60cm
Package 3 Length 80cm 80cm 80cm 80cm
Package 3 Weight 87.264kg 83.328kg 76.112kg 75.728 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LRD3359C LRD3361C LRD3363C LRD3365C
Product Series TeSys TeSys TeSys TeSys
product name TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
TeSys LRD
TeSys Deca
product type Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay
product short name LRD LRD LRD LRD
Relay application Motor protection Motor protection Motor protection Motor protection
The scope of products Compatible with LC1D50…D95 Compatible with LC1D50…D95 Compatible with LC1D65…D95 LC1D95
LC1D80
Relay setting range 48…65A 55…70A 63…80A 80…104A
Additional information
control type Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Red (push) button: stop (make N/C contact act, not affect N/O contact)
blue (push) button: reset
Current setting range 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits 0.75 A at 480 V AC-15 for signal circuits
Thermal release drag rating Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1
Trip threshold 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1
phase loss sensitivity 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5 6 kV according to IEC 60801-5
Conventional thermal current [Ith] 5 A for signal circuits 5 A for signal circuits 5 A for signal circuits 5 A for signal circuits
installation method Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Mount directly on the bottom of the contactor
DIN
rail mount terminal block
Wiring capacity Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² cable option: flexible without wire terminals
Control circuit: screw fastening1 1…2.5 mm² cable option: flexible cable with wire terminals
Control circuit: spring terminal1 1…2.5 mm² cable option: Flexible cord without wire terminals
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord without wire terminal
Power circuit: screw-on1 4…35 mm² Cable option: flexible cord with bar terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Screw fast2 1…2.5 mm² Cable option: Solid without wire terminals
Control circuit: Spring terminal1 1…2.5 mm² cable option: solid without wire terminals
Power circuit: screw fastening1 4…35 mm² cable option: solid without wire terminals
Tightening torque Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
Control circuit: 1.7 Nm Bolt-on
Power circuit: 9 Nm Bolt-on
width 70 mm 70 mm 70 mm 70 mm
depth 109mm 109mm 109mm 109mm
Product Weight 0.51kg 0.51kg 0.51kg 0.51kg
environment
Standards compliant IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
certified product CE
CCC
UKCA
CE
CCC
UKCA
CE
CCC
UKCA
CE
CCC
UKCA
IP protection class IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
ambient temperature -20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
storage environment temperature -60…70°C -60…70°C -60…70°C -60…70°C
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1
flame retardant V1 complies with UL 94 V1 complies with UL 94 V1 complies with UL 94 V1 complies with UL 94
Shock and vibration resistance Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Shock resistance: 6 gn, conforming to IEC 60068-2-6
Shock resistance: 15 gn, , 11 ms conforming to IEC 60068-2-7
Insulation properties 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 7.826 cm 7.51cm 7.94cm 8.138 cm
Package 1 Width 9.092 cm 8.79cm 8.96cm 8.763 cm
Package 1 Length 12.587 cm 12.23cm 12.53cm 12.439 cm
Package 1 Weight 470g 523.03g 525.91g 571.1g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 9 9 9 9
Package 2 Height 15cm 15cm 15cm 15cm
Package 2 Width 30cm 30cm 30cm 30cm
Package 2 Length 40cm 40cm 40cm 40cm
Package 2 Weight 4.66kg 4.883 kg 4.918 kg 5kg
Unit Type of Package 3 PAL PAL PAL PAL
Number of Units in Package 3 144 144 144 144
Package 3 Height 75cm 75cm 75cm 75cm
Package 3 Width 60cm 60cm 60cm 60cm
Package 3 Length 80cm 80cm 80cm 80cm
Package 3 Weight 75.728 kg 77.36 kg 77.36 kg 77.36 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Additional information