USD $ 27.14 – USD $ 77.28
Main | ||||
Part Number | LC1D32M7 | LC1D32B7C | LC1D32BDC | LC1D32CC7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V AC 50/60Hz | 24 V AC 50/60 Hz | 24 V DC | 36 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 7.5 kW at 220…230 V AC 50/60 Hz (AC-3) 15 kW at 380…400 V AC 50/60 Hz (AC-3) 15 kW at 415.. .440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3 ) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 7.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 15 kW at 380…400 V AC 50/60 Hz (AC-3e) 15 kW at 415…440 V AC 50/60 Hz (AC-3e) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
Motor Power | 2 hp at 115 V AC 50/60 Hz for 1-phase motors 5 hp at 230/240 V AC 50/60 Hz for 1-phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 Phase motor 10 hp at 230/240 V AC 50/60 Hz for 3 phase motor 20 hp at 460/480 V AC 50/60 Hz for 3 phase motor 30 hp at 575/600 V AC 50/ 60 Hz for 3-phase motors |
|||
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
Contactor Compatibility Features | M2 | |||
protection cap | Bring | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
Rated making capacity [Irms] | 140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 550 A at 440 V for power circuits according to IEC 60947 |
|||
Rated breaking capacity | 550 A at 440 V for power circuits conforming to IEC 60947 | |||
Rated short-time withstand current [Icw] | 260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits |
power consumption per pole | 2W AC-3 5W AC-1 2W AC-3e |
|||
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 15 Mcycles | 15 Mcycles | 30 Mcycles | 15 Mcycles |
Electrical life | 1.65 Mcycles 32 A AC-3 Ue <= 440 V 1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.65 Mcycles 32 A AC-3e Ue <= 440 V |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz standard | AC at 50/60 Hz | DC standard | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | Built-in bidirectional peak current limiting diode | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz 0.8…1.1 Uc -40…60 °C Run AC 50 Hz 0.85…1.1 Uc -40…60 °C Run AC 60 Hz 1…1.1 Uc 60…70 °C Operation AC 50/60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
|
(~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | |
action time | 12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
55 ms to close, 20 ms to break |
12…22 ms close 4…19 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Hard wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable option: Hard wire without wire terminal Power circuit: Bolt tight1 2.5…10 mm² Cable option: Flexible wire without wire Wire terminal power circuit: screw-on2 2.5…10 mm² Cable option: flexible without cable terminal Power circuit: screw-on1 1…10 mm² cable option: flexible with cable terminal Power circuit: screw-on Solid2 1.5…6 mm² Cable option: flexible cable with wire terminals Power circuit: screw fastened1 1.5…10 mm² Cable option: solid without cable terminals Power circuit: screw screwed2 2.5…10 mm² cable Type selection: hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for tightening Phillips screw Control circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts Power circuit: 2.5 Nm Screwdriver pozidriv No. 2 for tightening via bolts |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | ||||
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
certified product | DNV RINA LROS (Lloyds register of shipping) CCC CSA GL GOST BV UL UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP20 front panel conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
|||
ambient air temperature | -40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 0…3000m | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
flame retardant | V1 complies with UL 94 | |||
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts closed (15 gn (11ms)) Shock performance Contact opening (8 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
high | 85 mm | 85 mm | 85 mm | 85 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 92 mm | 92 mm | 101 mm | 92 mm |
Product Weight | 0.375kg | 0.375kg | 0.375kg | 0.375kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5cm | 5.457 cm | 5.409 cm | 5.438 cm |
Package 1 Width | 9.2 cm | 8.941 cm | 8.776 cm | 9.078 cm |
Package 1 Length | 11.2 cm | 9.958 cm | 10.949 cm | 10.034 cm |
Package 1 Weight | 410g | 401.0g | 580.0g | 401.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 20 | 21 | 20 | 21 |
Package 2 Height | 15cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 8.502kg | 9.11kg | 12.0 kg | 9.051 kg |
Unit Type of Package 3 | P06 | PAL | PAL | PAL |
Number of Units in Package 3 | 160 | 336 | 320 | 336 |
Package 3 Height | 45cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 60cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 80cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 76.016kg | 151.488 kg | 191.237 kg | 143.692kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D32E7C | LC1D32F7C | LC1D32FDC | LC1D32M7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | 110V AC 50/60Hz | 110V AC 50/60Hz | 230V AC 50/60Hz |
Additional information | ||||
Motor power (kW) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 15 Mcycles | 15 Mcycles | 15 Mcycles | 15 Mcycles |
Electrical life | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz |
action time | 12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | ||||
standard | IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
high | 85 mm | 85 mm | 85 mm | 85 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 92 mm | 92 mm | 92 mm | 92 mm |
Product Weight | 0.375kg | 0.375kg | 0.375kg | 0.375kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 8.8cm | 8.8cm | 8.8cm | 5.431 cm |
Package 1 Width | 9.9 cm | 9.9 cm | 9.9 cm | 8.741 cm |
Package 1 Length | 5.1 cm | 5.1 cm | 5.1 cm | 9.9 cm |
Package 1 Weight | 391.48g | 439.83g | 439.83g | 401.0g |
Unit Type of Package 2 | CAR | CAR | CAR | S02 |
Number of Units in Package 2 | Twenty one | Twenty one | Twenty one | Twenty one |
Package 2 Height | 30.0cm | 30.0cm | 30.0cm | 15.0cm |
Package 2 Width | 40.0cm | 40.0cm | 40.0cm | 30.0cm |
Package 2 Length | 15.0cm | 15.0cm | 15.0cm | 40.0cm |
Package 2 Weight | 8.271kg | 9.286kg | 9.286kg | 9.0 kg |
Unit Type of Package 3 | PAL | PAL | PAL | PAL |
Number of Units in Package 3 | 336 | 336 | 336 | 336 |
Package 3 Height | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 131.736 kg | 147.984 kg | 147.984 kg | 144.998kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | |||
Part Number | LC1D32MDC | LC1D32P7C | LC1D32Q7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
32 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 32 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V DC | 230 V AC 50/60 Hz | 380 V AC 50/60 Hz |
Additional information | |||
Motor power (kW) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 7.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 15 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415/440 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
model | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
260 A at <40 °C – 10 s for power circuit 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 138 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 30 Mcycles | 15 Mcycles | 15 Mcycles |
Electrical life | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
1.4 Mcycles 50 A AC-1 Ue <= 440 V 1.6 Mcycles 32 A AC-3 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.6 Mcycles 32 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue |
Control loop characteristics | DC standard | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | Built-in bidirectional peak current limiting diode | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
Surge power (W) | 5.4W (20°C) | ||
Holding power consumption(W) | 5.4 W at 20 °C | ||
Rated operating power (W) | 5.4W | ||
action time | 55 ms to close, 20 ms to break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
time constant | 28ms | ||
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal |
Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | ||
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | |||
standard | GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 |
high | 85 mm | 85 mm | 85 mm |
width | 45 mm | 45 mm | 45 mm |
depth | 101 mm | 92 mm | 92 mm |
Product Weight | 0.375kg | 0.375kg | 0.375kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 8.8cm | 5.417 cm | 5.362 cm |
Package 1 Width | 10.6 cm | 8.79cm | 8.921 cm |
Package 1 Length | 5.2 cm | 9.961 cm | 10.068 cm |
Package 1 Weight | 392.3g | 410.0g | 401.0g |
Unit Type of Package 2 | CAR | S02 | S02 |
Number of Units in Package 2 | 20 | 21 | 21 |
Package 2 Height | 30.0cm | 15.0cm | 15.0cm |
Package 2 Width | 40.0cm | 30.0cm | 30.0cm |
Package 2 Length | 15.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 7.896 kg | 9.12 kg | 8.98kg |
Unit Type of Package 3 | PAL | PAL | PAL |
Number of Units in Package 3 | 320 | 336 | 336 |
Package 3 Height | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 125.736kg | 148.448 kg | 147.936kg |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)
inosaki.com 2008 -2024