$ 117.76
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3/AC-3e (45kW@400V). It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Main | |
Range | TeSys |
Range of product | TeSys Deca |
Contactor application | Motor control |
Utilisation category | AC-3 |
AC-4 | |
AC-1 | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz |
[Ie] rated operational current | 95 A (at <60 °C) at <= 440 V AC-3 for power circuit |
95 A (at <60 °C) at <= 440 V AC-3e for power circuit | |
[Uc] control circuit voltage | 24 V AC 50/60 Hz |
45 kW at 415…440 V AC 50 Hz (AC-3) | |
55 kW at 500 V AC 50 Hz (AC-3) | |
15 kW at 400 V AC 50 Hz (AC-4) | |
45 kW at 380…400 V AC 50 Hz (AC-3e) | |
45 kW at 660…690 V AC 50 Hz (AC-3e) | |
15 hp at 230/240 V AC 60 Hz for 1 phase motors | |
30 hp at 200/208 V AC 60 Hz for 3 phases motors | |
30 hp at 230/240 V AC 60 Hz for 3 phases motors | |
60 hp at 575/600 V AC 60 Hz for 3 phases motors | |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit |
125 A (at 60 °C) for power circuit | |
140 A AC for signalling circuit conforming to IEC 60947-5-1 | |
250 A DC for signalling circuit conforming to IEC 60947-5-1 | |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
800 A 40 °C – 10 s for power circuit | |
400 A 40 °C – 1 min for power circuit | |
120 A – 500 ms for signalling circuit | |
100 A – 1 s for signalling circuit | |
Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
200 A gG at <= 690 V coordination type 1 for power circuit | |
160 A gG at <= 690 V coordination type 2 for power circuit | |
Power dissipation per pole | 12.5 W AC-1 |
[Ui] rated insulation voltage | Power circuit: 1000 V conforming to IEC 60947-4-1 |
Power circuit: 600 V CSA certified | |
Power circuit: 600 V UL certified | |
Signalling circuit: 600 V CSA certified | |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Safety reliability level | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 |
Mechanical durability | 4 Mcycles |
Electrical durability | 1.2 Mcycles 95 A AC-3 |
1.3 Mcycles 125 A AC-1 | |
Control circuit type | AC at 50/60 Hz standard |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz |
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz | |
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz | |
Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) |
245 VA 50 Hz cos phi 0.75 (at 20 °C) | |
Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 6…10 W at 50/60 Hz |
Operating time | 20…35 ms closing |
6…20 ms opening | |
Maximum operating rate | 3600 cyc/h 60 °C |
Connections – terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end |
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end | |
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end | |
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end | |
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end | |
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end | |
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end | |
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end | |
Tightening torque | Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm |
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 | |
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm | |
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm | |
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 | |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
type mirror contact 1 NC conforming to IEC 60947-4-1 | |
Signalling circuit frequency | 25…400 Hz |
Minimum switching voltage | 17 V for signalling circuit |
Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact |
1.5 ms on energisation between NC and NO contact | |
Mounting support | Plate |
Rail | |
Environment | |
Standards | EN/IEC 60947-1 |
EN/IEC 60947-4-1 | |
EN/IEC 60947-5-1 | |
UL 60947-4-1 | |
UL 60947-5-1 | |
CSA C22.2 No 60947-4-1 | |
CSA C22.2 No 60947-5-1 | |
GB/T 14048.4 | |
Product certifications | IECEE CB Scheme |
UL | |
CSA | |
CCC | |
EAC | |
LROS (Lloyds register of shipping) | |
RINA | |
BV | |
DNV-GL | |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Protective treatment | TH conforming to IEC 60068-2-30 |
Climatic withstand | Conforming to IACS E10 exposure to damp heat |
Permissible ambient air temperature around the device | -40…60 °C |
60…70 °C with derating | |
Operating altitude | 0…3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz) |
Shocks contactor open (8 Gn for 11 ms) | |
Vibrations contactor closed (3 Gn, 5…300 Hz) | |
Shocks contactor closed (10 Gn for 11 ms) | |
Height | 127 mm |
Width | 85 mm |
Depth | 130 mm |
Product weight | 1.61 kg |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 9.5 cm |
Package 1 Width | 13.5 cm |
Package 1 Length | 14 cm |
Package 1 Weight | 1.564 kg |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 5 |
Package 2 Height | 15 cm |
Package 2 Width | 30 cm |
Package 2 Length | 40 cm |
Package 2 Weight | 8.275 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 80 |
Package 3 Height | 80 cm |
Package 3 Width | 80 cm |
Package 3 Length | 60 cm |
Package 3 Weight | 140.9 kg |
Contractual warranty | |
Warranty | 18 months |
Weight | 1.610 kg |
---|---|
Dimensions | 13 × 8.5 × 12.7 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)