$ 205.62 $ 168.61
Manufacturer Part Number: Festo 8074906
Festo Pressure Sensors And Vacuum Sensors: SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D
OEM Spec Ref
The Festo SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D, with MPN 8074906 Pressure Sensors And Vacuum Sensors, is a state-of-the-art pressure sensor designed for precise and reliable monitoring within pneumatic systems. This high-performance sensor is engineered to integrate seamlessly into a variety of industrial applications, ensuring consistent operation and enhanced system efficiency.
Key Features:
Benefits:
Applications:
The Festo SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D Pressure Sensors And Vacuum Sensors stands as a testament to Festo’s commitment to advancing pneumatic and sensor technology, providing a sophisticated solution for managing system pressure and optimizing the performance of industrial processes.
Feature | Specification |
---|---|
Symbol | 00995410 |
Certification | RCM compliance mark c UL us – Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive |
UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
KC characters | KC EMC |
Note on materials | RoHS-compliant |
Measured variable | Relative pressure |
Method of measurement | Piezoresistive pressure sensor |
Pressure measuring range initial value | 0 MPa |
Pressure measuring range initial value | 0 bar |
Pressure measuring range initial value | 0 psi |
Pressure measuring range end value | 1 MPa |
Pressure measuring range end value | 10 bar |
Pressure measuring range end value | 145 psi |
Max. overload pressure | 15 bar |
Overload pressure | 1.5 MPa |
Overload pressure | 15 bar |
Overload pressure | 217.5 psi |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas |
Information on operating and pilot media | Operation with oil lubrication possible |
Temperature of medium | 0 °C … 50 °C |
Ambient temperature | 0 °C … 50 °C |
ADC resolution | 12 bit |
Accuracy in ± % FS | 1.5 %FS |
Repetition accuracy in ± %FS | 0.3 %FS |
Temperature co-efficient in ± %FS/K | 0.05 %FS/K |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Freely programmable |
Switching element function | N/C contact/N/O contact switchable |
Max. output current | 100 mA |
Analog output | 0 – 10 V 4 – 20 mA 1 – 5 V |
Rise time | 3 ms |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 10 kOhm |
Short-circuit protection | Yes |
Protocol | IO-Link® |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBd) |
IO-Link®, SIO mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width OUT | 0 Byte |
IO-Link®, process data width IN | 2 Byte |
IO-Link®, process data content IN | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) |
IO-Link®, minimum cycle time | 3 ms |
IO-Link®, data memory required | 500 byte |
DC operating voltage range | 20 V … 30 V |
Reverse polarity protection | For all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connection technology | M12x1 A-coded as per EN 61076-2-101 |
Electrical connection 1, number of pins/wires | 4 |
Electrical connection for input 1, connection pattern | 00995386 |
Type of mounting | On service unit |
Mounting position | Any |
Pneumatic connection | Flange |
Product weight | 80 g |
Display type | Illuminated LCD |
Displayable unit(s) | MPa bar inH2O inHg kPa kgf/cm² mmHg psi |
Setting options | IO-Link® Teach-in Via display and pushbuttons |
Protection against tampering | IO-Link® PIN code |
Setting range threshold value | 0 % … 100 % |
Setting range hysteresis | 0 % … 90 % |
Degree of protection | IP65 |
Corrosion resistance class (CRC) | 2 – Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Weight | 0.080 kg |
---|
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)