Part number | 3RV6021-4AA10 | 3RV6021-4BA10 | 3RV6021-4CA10 | 3RV6021-4DA10 |
product brand name | SIRIUS | SIRIUS | SIRIUS | SIRIUS |
product designation | Circuit breaker | Circuit breaker | Circuit breaker | Circuit breaker |
design of the product | for motor protection | for motor protection | for motor protection | for motor protection |
product type designation | 3RV6 | 3RV6 | 3RV6 | 3RV6 |
General technical data | ||||
size of the circuit-breaker | S0 | S0 | S0 | S0 |
power loss [W] total typical | 7 W | 8 W | 8 W | 8 W |
insulation voltage with degree of pollution 3 at AC rated value | 690 V | 690 V | 690 V | 690 V |
surge voltage resistance rated value | 6 kV | 6 kV | 6 kV | 6 kV |
shock resistance according to IEC 60068-2-27 | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms |
Substance Prohibitance (Date) | 5/1/2012 | 5/1/2012 | 5/1/2012 | 5/1/2012 |
Ambient conditions | ||||
installation altitude at height above sea level maximum | 2 000 m | 2 000 m | 2 000 m | 2 000 m |
ambient temperature | ||||
? during operation | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C |
? during transport | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C |
relative humidity during operation | 10 … 95 % | 10 … 95 % | 10 … 95 % | 10 … 95 % |
Main circuit | ||||
number of poles for main current circuit | 3 | 3 | 3 | 3 |
adjustable current response value current of the current-dependent overload release | 10 … 16 A | 13 … 20 A | 16 … 22 A | 18 … 25 A |
operating voltage | ||||
rated value | 690 V | 690 V | 690 V | 690 V |
at AC-3 rated value maximum | 690 V | 690 V | 690 V | 690 V |
operating frequency rated value | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz |
operational current rated value 25 A | 16 A | 20 A | 22 A | 25 A |
operational current at AC-3 at 400 V rated value | 16 A | 20 A | 22 A | 25 A |
operating frequency at AC-3 maximum | 15 1/h | 15 1/h | 15 1/h | 15 1/h |
Protective and monitoring functions | ||||
trip class | CLASS 10 | CLASS 10 | CLASS 10 | CLASS 10 |
design of the overload release | thermal | thermal | thermal | thermal |
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value | 55 kA | 55 kA | 55 kA | 55 kA |
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value | 25 kA | 25 kA | 25 kA | 25 kA |
response value current of instantaneous short-circuit trip unit | 208 A | 260 A | 286 A | 325 A |
Short-circuit protection | ||||
product function short circuit protection | Yes | Yes | Yes | Yes |
design of the short-circuit trip | magnetic | magnetic | magnetic | magnetic |
Installation/ mounting/ dimensions | ||||
mounting position | any | any | any | any |
fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
height | 97 mm | 97 mm | 97 mm | 97 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 96 mm | 96 mm | 96 mm | 96 mm |
required spacing for grounded parts | ||||
forwards | 0 mm | 0 mm | 0 mm | 0 mm |
backwards | 0 mm | 0 mm | 0 mm | 0 mm |
upwards | 50 mm | 50 mm | 50 mm | 50 mm |
at the side | 30 mm | 30 mm | 30 mm | 30 mm |
downwards | 50 mm | 50 mm | 50 mm | 50 mm |
Connections/ Terminals | ||||
type of electrical connection | ||||
for main current circuit | screw-type terminals | screw-type terminals | screw-type terminals | screw-type terminals |
arrangement of electrical connectors for main current circuit | Top and bottom | Top and bottom | Top and bottom | Top and bottom |
type of connectable conductor cross-sections | ||||
for main contacts | ||||
— solid or stranded | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
— finely stranded with core end processing | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
at AWG cables for main contacts | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) |
tightening torque | ||||
for main contacts with screw-type terminals | 2 … 2.5 N·m | 2 … 2.5 N·m | 2 … 2.5 N·m | 2 … 2.5 N·m |
Safety related data | ||||
protection class IP on the front according to IEC 60529 | IP20 | IP20 | IP20 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front |
Part number | 3RV6021-4EA10 | 3RV6021-4FA10 | 3RV6021-4NA10 | 3RV6021-4PA10 |
product brand name | SIRIUS | SIRIUS | SIRIUS | SIRIUS |
product designation | Circuit breaker | Circuit breaker | Circuit breaker | Circuit breaker |
design of the product | for motor protection | for motor protection | for motor protection | for motor protection |
product type designation | 3RV6 | 3RV6 | 3RV6 | 3RV6 |
General technical data | ||||
size of the circuit-breaker | S0 | S0 | S0 | S0 |
power loss [W] total typical | 11 W | 14 W | 11 W | 14 W |
insulation voltage with degree of pollution 3 at AC rated value | 690 V | 690 V | 690 V | 690 V |
surge voltage resistance rated value | 6 kV | 6 kV | 6 kV | 6 kV |
shock resistance according to IEC 60068-2-27 | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms |
Substance Prohibitance (Date) | 5/1/2012 | 5/1/2012 | 5/1/2012 | 5/1/2012 |
Ambient conditions | ||||
installation altitude at height above sea level maximum | 2 000 m | 2 000 m | 2 000 m | 2 000 m |
ambient temperature | ||||
? during operation | -20 … +60 °C | -20 … +40 °C | -20 … +60 °C | -20 … +40 °C |
? during transport | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C |
relative humidity during operation | 10 … 95 % | 10 … 95 % | 10 … 95 % | 10 … 95 % |
Main circuit | ||||
number of poles for main current circuit | 3 | 3 | 3 | 3 |
adjustable current response value current of the current-dependent overload release | 27 … 32 A | 34 … 40 A | 23 … 28 A | 30 … 36 A |
operating voltage | ||||
rated value | 690 V | 690 V | 690 V | 690 V |
at AC-3 rated value maximum | 690 V | 690 V | 690 V | 690 V |
operating frequency rated value | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz |
operational current rated value 25 A | 32 A | 40 A | 28 A | 36 A |
operational current at AC-3 at 400 V rated value | 32 A | 40 A | 28 A | 36 A |
operating frequency at AC-3 maximum | 15 1/h | 15 1/h | 15 1/h | 15 1/h |
Protective and monitoring functions | ||||
trip class | CLASS 10 | CLASS 10 | CLASS 10 | CLASS 10 |
design of the overload release | thermal | thermal | thermal | thermal |
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value | 55 kA | 20 kA | 55 kA | 20 kA |
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value | 25 kA | 10 kA | 25 kA | 10 kA |
response value current of instantaneous short-circuit trip unit | 400 A | 480 A | 364 A | 432 A |
Short-circuit protection | ||||
product function short circuit protection | Yes | Yes | Yes | Yes |
design of the short-circuit trip | magnetic | magnetic | magnetic | magnetic |
Installation/ mounting/ dimensions | ||||
mounting position | any | any | any | any |
fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 |
height | 97 mm | 97 mm | 97 mm | 97 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 96 mm | 96 mm | 96 mm | 96 mm |
required spacing for grounded parts | ||||
forwards | 0 mm | 0 mm | 0 mm | 0 mm |
backwards | 0 mm | 0 mm | 0 mm | 0 mm |
upwards | 50 mm | 70 mm | 50 mm | 70 mm |
at the side | 30 mm | 30 mm | 30 mm | 30 mm |
downwards | 50 mm | 70 mm | 50 mm | 70 mm |
Connections/ Terminals | ||||
type of electrical connection | ||||
for main current circuit | screw-type terminals | screw-type terminals | screw-type terminals | screw-type terminals |
arrangement of electrical connectors for main current circuit | Top and bottom | Top and bottom | Top and bottom | Top and bottom |
type of connectable conductor cross-sections | ||||
for main contacts | ||||
— solid or stranded | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
— finely stranded with core end processing | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
at AWG cables for main contacts | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) | 2x (16 … 12), 2x (14 … 8) |
tightening torque | ||||
for main contacts with screw-type terminals | 2 … 2.5 N·m | 2 … 2.5 N·m | 2 … 2.5 N·m | 2 … 2.5 N·m |
Safety related data | ||||
protection class IP on the front according to IEC 60529 | IP20 | IP20 | IP20 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details