The power supplies supply the S7-400 modules with their 5 V DC and 24 V DC operating voltages via the backplane bus.
Power supplies are available for AC line voltages of 85 to 264 V and for DC voltages of 19.2 to 300 V.
One power supply module is required per rack.
Exception:
With interfaces with current transfer, the power supply module in the central controller also supplies all modules in the expansion units.
The load voltage for supplying sensors and actuators must be made available separately.
There are also power supplies to make both the standard system and the H system fail-safe (redundant power supplies).
Siemens Power Supply S7-400 Product Specifications:
Article number | 6ES7407-0DA02-0AA0 | 6ES7407-0KA02-0AA0 | 6ES7407-0KR02-0AA0 | 6ES7407-0RA02-0AA0 |
POWER SUPPLY PS407, 120/230V UC,5V DC/4A | PS407 POWER SUPPLY,120/230V UC,5V DC/10A | POWERSUPP.PS407,UC120/230V,DC5V/10A,RED. | PS407 POWER SUPPLY,120/230V UC,5V DC/20A | |
Supply voltage | ||||
Rated value (DC) | ||||
● 120 V DC | Yes | Yes | Yes | Yes |
● 230 V DC | Yes | Yes | Yes | Yes |
Rated value (AC) | ||||
● 120 V AC | Yes | Yes | Yes | Yes |
● 230 V AC | Yes | Yes | Yes | Yes |
Line frequency | ||||
● Rated value 50 Hz | Yes | Yes | Yes | Yes |
● Rated value 60 Hz | Yes | Yes | Yes | Yes |
● permissible range, lower limit | 47 Hz | 47 Hz | 47 Hz | 47 Hz |
● permissible range, upper limit | 63 Hz | 63 Hz | 63 Hz | 63 Hz |
Mains buffering | ||||
● Mains/voltage failure stored energy time | 20 ms | 20 ms | 20 ms | 20 ms |
● Mains buffering according to NAMUR recommendation | Yes | Yes | Yes | Yes |
Input current | ||||
Rated value at 120 V DC | 350 mA | 1 A | 1 A | 1.4 A |
Rated value at 230 V DC | 190 mA | 0.5 A | 0.5 A | 0.7 A |
Rated value at 120 V AC | 0.42 A | 0.9 A | 0.9 A | 1.4 A |
Rated value at 230 V AC | 0.22 A | 0.5 A | 0.5 A | 0.7 A |
Inrush current, max. | 8.25 A; Full width at half maximum 5 ms | 63 A; Full width at half maximum 1 ms | 63 A; Full width at half maximum 1 ms | 88 A; Full width at half maximum 1.1 ms |
Leakage current, max. | 3.5 mA | 3.5 mA | 3.5 mA | 3.5 mA |
output voltage / header | ||||
Type of output voltage | DC | DC | DC | DC |
Rated value (DC) | ||||
● 5 V DC | Yes | Yes | Yes | Yes |
● 24 V DC | Yes | Yes | Yes | Yes |
Output current | ||||
for backplane bus (5 V DC), max. | 4 A; no base load required | 10 A; no base load required | 10 A; no base load required | 20 A; no base load required |
for backplane bus (24 V DC), max. | 0.5 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof |
Short-circuit protection | Yes | Yes | Yes | Yes |
Power | ||||
Active power input, typ. | 52 W | 95 W | 95 W | 158 W |
Power loss | ||||
Power loss, typ. | 20 W | 20 W | 20 W | 35 W |
Battery | ||||
Backup battery | ||||
● Backup battery (optional) | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah |
Hardware configuration | ||||
Slots | ||||
● required slots | 1 | 2 | 2 | 2 |
Potential separation | ||||
primary/secondary | Yes | Yes | Yes | Yes |
Isolation | ||||
Overvoltage category | II | II | II | II |
EMC | ||||
Compliance with line harmonic distortion limits | ||||
● Compliance with line harmonic distortion acc. to IEC 61000-3-2, IEC 61000-3-3 | Yes | Yes | Yes | Yes |
Degree and class of protection | ||||
Equipment protection class | I, with protective conductor | I, with protective conductor | I, with protective conductor | I, with protective conductor |
Standards, approvals, certificates | ||||
FM approval | Yes; Ta: 0 °C to 70 °C T4 | Yes; Ta: 0 °C to 70 °C T4 | Yes; Ta: 0 °C to 70 °C T4 | Yes; Ta: 0 °C to 70 °C T4 |
Ambient conditions | ||||
Ambient temperature during operation | ||||
● min. | 0 °C | 0 °C | 0 °C | 0 °C |
● max. | 60 °C | 60 °C | 60 °C | 60 °C |
connection method / header | ||||
Design of electrical connection | 3x 1.5 mm², solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm², solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm², solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm², solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm |
Dimensions | ||||
Width | 25 mm | 50 mm | 50 mm | 50 mm |
Height | 290 mm | 290 mm | 290 mm | 290 mm |
Depth | 217 mm | 217 mm | 217 mm | 217 mm |
Weights | ||||
Weight, approx. | 760 g | 1 200 g | 1 200 g | 1 300 g |