SIMATIC HMI – KTP400 Comfort Panels Standard Devices – Siemens Comfort Panels
USD $ 827.20
SKU: 6AV2124-2DC01-0AX0
SIMATIC HMI KTP400 Comfort, Comfort Panel, key/touch operation, 4″ widescreen TFT display, 16 million colors, PROFINET interface, MPI/PROFIBUS DP interface, 4 MB configuration memory, Windows CE 6.0, configurable from WinCC Comfort V11
Siemens HMI Comfort Panels Product Specifications:
General information | |
Article Number | 6AV2124-2DC01-0AX0 |
Product type designation | KTP400 Comfort |
Display | |
Design of display | TFT |
Screen diagonal | 4.3 in |
Display width | 95 mm |
Display height | 53.8 mm |
Number of colors | 16 777 216 |
Resolution (pixels) | |
● Horizontal image resolution | 480 pixel |
● Vertical image resolution | 272 pixel |
Backlighting | |
● MTBF backlighting (at 25 °C) | 80 000 h |
● Backlight dimmable | Yes; 0-100 % |
Control elements | |
Keyboard fonts | |
● Function keys | |
— Number of function keys | 4 |
— Number of function keys with LEDs | 4 |
● Keys with LED | Yes |
● System keys | No |
● Numeric keyboard | Yes; Onscreen keyboard |
● alphanumeric keyboard | Yes; Onscreen keyboard |
Touch operation | |
● Design as touch screen | Yes; Analog-resistive |
Expansions for operator control of the process | |
● DP direct LEDs (LEDs as S7 output I/O) | |
— F1…Fx | 4 |
● Direct keys (keys as S7 input I/O) | |
— F1…Fx | 4 |
● Direct keys (touch buttons as S7 input I/O) | 32 |
Installation type/mounting | |
Mounting position | vertical |
Wall mounting/direct mounting | No |
Mounting in portrait format possible | Yes |
Mounting in landscape format possible | Yes |
maximum permissible angle of inclination without external ventilation | 35° |
Supply voltage | |
Type of supply voltage | DC |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Input current | |
Current consumption (rated value) | 0.13 A |
Starting current inrush I²t | 0.5 A²·s |
Power | |
Active power input, typ. | 3.1 W |
Processor | |
Processor type | ARM |
Memory | |
Flash | Yes |
RAM | Yes |
Memory available for user data | 4 Mbyte |
Type of output | |
Info LED | No |
Power LED | No |
Error LED | No |
Acoustics | |
● Buzzer | Yes |
● Speaker | No |
Time of day | |
Clock | |
● Hardware clock (real-time) | Yes |
● Software clock | Yes |
● retentive | Yes; Back-up duration typically 6 weeks |
● synchronizable | Yes |
Interfaces | |
Number of industrial Ethernet interfaces | 1 |
Number of RS 485 interfaces | 1; RS 422 / 485 combined |
Number of RS 422 interfaces | 1 |
Number of RS 232 interfaces | 0 |
Number of USB interfaces | 1; USB 2.0 |
● USB Mini B | 1; 5-pole |
Number of 20 mA interfaces (TTY) | 0 |
Number of parallel interfaces | 0 |
Number of other interfaces | 0 |
Number of SD card slots | 2 |
With software interfaces | No |
Industrial Ethernet | |
● Industrial Ethernet status LED | 2 |
● Number of ports of the integrated switch | 1; No switch integrated |
Protocols | |
PROFINET | Yes |
Supports protocol for PROFINET IO | Yes |
IRT | No |
PROFIBUS | Yes |
EtherNet/IP | Yes |
MPI | Yes |
Protocols (Ethernet) | |
● TCP/IP | Yes |
● DHCP | Yes |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
WEB characteristics | |
● HTTP | Yes |
● HTTPS | No |
● HTML | Yes |
● XML● CSS | No |
● Active X | Yes |
● JavaScript | No |
● Java VM | Yes |
No | |
Redundancy mode | |
Media redundancy | |
— MRP | No |
Further protocols | |
● CAN | No |
● MODBUS | Yes |
Interrupts/diagnostics/status information | |
Diagnoses | |
● Diagnostic information readable | Yes; S7 controller |
EMC | |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas | Yes |
● Limit class B, for use in residential areas | No |
Degree and class of protection | |
IP (at the front) | IP65 |
IP (rear) | IP20 |
NEMA (front) | |
● Enclosure Type 4 at the front | Yes |
● Enclosure Type 4x at the front | Yes |
Standards, approvals, certificates | |
CE mark | Yes |
cULus | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
Use in hazardous areas | |
● ATEX Zone 2 | Yes |
● ATEX Zone 22 | Yes |
● IECEx Zone 2 | Yes |
● IECEx Zone 22 | Yes |
● cULus Class I Zone 1 | No |
● cULus Class I Zone 2, Division 2 | Yes |
● FM Class I Division 2 | Yes |
Marine approval | |
● Germanischer Lloyd (GL) | Yes |
● American Bureau of Shipping (ABS) | Yes |
● Bureau Veritas (BV) | Yes |
● Det Norske Veritas (DNV) | Yes |
● Lloyds Register of Shipping (LRS) | Yes |
● Nippon Kaiji Kyokai (Class NK) | Yes |
● Polski Rejestr Statkow (PRS) | No |
Ambient conditions | |
Ambient temperature during operation | |
Operation (vertical installation) | |
— For vertical installation, min. | 0 °C |
— For vertical installation, max. | 50 °C |
Operation (max. tilt angle) | |
— At maximum tilt angle, min. | 0 °C |
— At maximum tilt angle, max. | 40 °C |
Operation (vertical installation, portrait format) | |
— For vertical installation, min. | 0 °C |
— For vertical installation, max. | 40 °C |
Operation (max. tilt angle, portrait format) | |
— At maximum tilt angle, min. | 0 °C |
— At maximum tilt angle, max. | 35 °C |
Ambient temperature during storage/transportation | |
● min. | -20 °C |
● max. | 60 °C |
Relative humidity | |
● Operation, max. | 90 %; no condensation |
Operating systems | |
proprietary | No |
pre-installed operating system | |
● Windows CE | Yes |
configuration / header | |
Message indicator | Yes |
Alarm system (incl. buffer and acknowledgment) | Yes |
Process value display (output) | Yes |
Process value default (input) possible | Yes |
Recipe management | Yes |
Configuration software | |
● STEP 7 Basic (TIA Portal) | No |
● STEP 7 Professional (TIA Portal) | No |
● WinCC flexible Compact | No |
● WinCC flexible Standard | No |
● WinCC flexible Advanced● WinCC Basic (TIA Portal) | No |
● WinCC Comfort (TIA Portal) | No |
● WinCC Advanced (TIA Portal) | Yes; from V11 |
● WinCC Professional (TIA Portal) | Yes; from V11 |
Yes; from V11 | |
Languages | |
Online languages | |
● Number of online/runtime languages | 32 |
Project languages | |
● Languages per project | 32 |
Functionality under WinCC (TIA Portal) | |
Libraries | Yes |
Applications/options | |
● Web browser | Yes |
● Pocket Word | Yes |
● Pocket Excel | Yes |
● PDF Viewer | Yes |
● Media Player | Yes |
● SIMATIC WinCC Sm@rtServer | Yes |
● SIMATIC WinCC Audit | Yes |
Number of Visual Basic Scripts | Yes |
Task planner | |
● time-controlled | Yes |
● task-controlled | Yes |
Message system | |
● Number of alarm classes● Bit messages | 32 |
— Number of bit messages ● Analog messages | Yes |
— Number of analog messages | 2 000 |
● S7 alarm number procedure | Yes |
● System messages HMI | 50 |
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, … ) | Yes |
● Number of characters per message | Yes |
● Number of process values per message | Yes |
● Acknowledgment groups | 80 |
● Message indicator | 8 |
Yes | |
Yes | |
Recipe management | |
● Number of recipes | 100 |
● Data records per recipe | 200 |
● Entries per data record | 200 |
● Size of internal recipe memory | 512 kbyte |
● Recipe memory expandable | Yes |
Variables | |
● Number of variables per device | 1 024 |
● Number of variables per screen | 50 |
● Limit values● Multiplexing | Yes |
● Structures | Yes |
● Arrays | Yes |
Yes | |
Images | |
● Number of configurable images | 500 |
● Permanent window/default | Yes |
● Global image | Yes |
● Pop-up images | Yes |
● Slide-in images | Yes |
● Image selection by PLC | Yes |
● Image number in the PLC | Yes |
Image objects | |
● Number of objects per image | 50 |
● Text fields | Yes |
● I/O fields | Yes |
● Graphic I/O fields (graphics list) | Yes |
● Symbolic I/O fields (text list) | Yes |
● Date/time fields | Yes |
● Switches | Yes |
● Buttons | Yes |
● Graphic display | Yes |
● Icons | Yes |
● Geometric objects | Yes |
Complex image objects | |
● Number of complex objects per screen | 5 |
● Alarm view● Trend view | Yes |
● User view | Yes |
● Status/control | Yes |
● Sm@rtClient view | Yes |
● Recipe view | Yes |
● f(x) trend view | Yes |
● System diagnostics view | Yes |
● Media Player | Yes |
● HTML browser | Yes |
● PDF display | No |
● IP camera display | Yes |
● Bar graphs | Yes |
● Sliders | Yes |
● Pointer instruments | Yes |
● Analog/digital clock | Yes |
Yes | |
Lists | |
● Number of text lists per project | 300 |
● Number of entries per text list | 30 |
● Number of graphics lists per project | 100 |
● Number of entries per graphics list | 30 |
Archiving | |
● Number of archives per device | 10 |
● Number of entries per archive | 10 000 |
● Message archive | Yes |
● Process value archive | Yes |
● Archiving methods | |
— Sequential archive | Yes |
— Short-term archive ● Memory location | Yes |
— Memory card | |
— USB memory | Yes |
— Ethernet | Yes |
● Data storage format | Yes |
— CSV | |
— TXT | Yes |
— RDB | Yes |
Yes | |
Security | |
● Number of user groups | 50 |
● Number of user rights | 32 |
● Number of users | 50 |
● Password export/import | Yes |
● SIMATIC Logon | Yes |
Logging through printer | |
● Alarms | Yes |
● Report (shift log) | Yes |
● Hardcopy | Yes |
● Electronic print to file | Yes; PDF, HTML |
Character sets | |
● Keyboard fonts | |
— US English | Yes |
Transfer (upload/download) | |
● MPI/PROFIBUS DP | Yes |
● USB | Yes |
● Ethernet | Yes |
● using external storage medium | Yes |
Process coupling | |
● S7-1200 | Yes |
● S7-1500 | Yes |
● S7-200 | Yes |
● S7-300/400● LOGO! | Yes |
● WinAC | Yes |
● SINUMERIK | Yes |
● SIMOTION | Yes; with SINUMERIK option package |
● Allen Bradley (EtherNet/IP) | Yes |
● Allen Bradley (DF1) | Yes |
● Mitsubishi (MC TCP/IP) | Yes |
● Mitsubishi (FX) | Yes |
● OMRON (FINS TCP) | Yes |
● OMRON (LINK/Multilink) | No |
● Modicon (Modbus TCP/IP) | Yes |
● Modicon (Modbus) | Yes |
● OPC UA Client | Yes |
● OPC UA Server | Yes |
Yes | |
Service tools/configuration aids | |
● Backup/Restore manually | Yes |
● Backup/Restore automatically | Yes |
● Simulation | Yes |
● Device switchover | Yes |
Peripherals/Options | |
Printer | Yes |
SIMATIC HMI MM memory card: Multi Media Card | Yes; Up to 128 MB |
SIMATIC HMI SD memory card: Secure Digital memory card | Yes; Up to 2 GB |
SIMATIC HMI CF memory card Compact Flash Card | No |
USB memory | Yes |
SIMATIC IPC USB Flashdrive (USB stick) | Yes; Up to 16 GB |
SIMATIC HMI USB stick | Yes; Up to 8 GB |
Network camera | Yes |
Mechanics/material | |
Enclosure material (front) | |
● Plastic | Yes |
● Aluminum | No |
● Stainless steel | No |
Dimensions | |
Width of the housing front | 140 mm |
Height of housing front | 116 mm |
Mounting cutout, width | 123 mm |
Mounting cutout, height | 99 mm |
Overall depth | 49 mm |
Weights | |
Weight (without packaging) | 0.6 kg |
Weight (with packaging) | 0.7 kg |
Weight | 0.684 kg |
---|---|
Dimensions | 13.1 × 20.1 × 6.8 cm |