SIMATIC ET 200SP – IM 155-6PN High Feature / Speed PROFINET Interface Modules – Siemens
USD $ 332.64 – USD $ 614.68
IM 155-6PN High Feature PROFINET interface module
The IM 155-6PN High Feature is designed mainly for PROFINET applications with a high, flexible demand for functions, as well as a large station expansion of up to 64 modules (max. 1024 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.
Unlike the other interface modules, the IM 155-6PN/2 HF supports the following additional functions:
- Use of BusAdapters, also with fiber-optic cable connection
- Increased data volume of up to 1440 bytes for both input and output data and up to 288 bytes per module
- Multi Hot Swap (withdrawing and insertion of any number of I/O modules during operation without impairing the communication with the remaining modules)
- S2 redundancy
- Isochronous mode from 250 µs
- Oversampling
- MSI/MSO
- Shared device with up to four controllers
- Up to four subslots per module
With its third port, the 3-port IM155-6PN/3 HF interface module allows the expansion of the PROFINET topology by a spur line. Typical applications are:
- Connection to a higher-level network
- Programming device access in the field
- Cable outlet via festoon cable system
The local IO data coupling allows data to be exchanged between up to 4 controllers quickly, deterministically, and without elaborate configuring.
IM 155-6PN High Speed PROFINET interface module
The IM 155-6PN High Speed is designed mainly for PROFINET applications with very short response times. All I/O modules, including PROFIsafe, can be used.
Compared to the IM 155-6PN HF, the IM 155-6PN HS has the following functional differences:
- For input and output data with up to 32 bytes per module, max. 30 modules per station
- Isochronous mode from 125 µs
- MRPD
- PROFINET Performance Upgrade (Fast Forwarding, Dynamic Frame Packaging, Fragmentation)
IM 155-6DP High Feature PROFIBUS interface module
The IM 155-DP High Feature is designed mainly for PROFIBUS applications with average station expansion of up to 32 modules (max. 512 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.
Siemens Interface Modules ET 200SP Product Specifications:
Article number | 6ES7155-6AU01-0CN0 | 6ES7155-6AU30-0CN0 | 6ES7155-6AU00-0DN0 | 6ES7155-6BA01-0CN0 |
ET 200SP, IM155-6PN/2 HF | ET 200SP, IM155-6PN/3 HF | ET 200SP, IM155-6PN HS | ET 200SP, IM155-6DP HF incl. DP-Connect. | |
General information | ||||
Product type designation | IM 155-6 PN/2 HF | IM 155-6 PN/3 HF | IM 155-6 PN HS | IM 155-6 DP HF |
HW functional status | From FS02 | From FS02 | From FS02 | From FS02 |
Firmware version | V4.2 | V4.2 | V4.0 | V4.2 |
● FW update possible | Yes | Yes | Yes | |
Product function | ||||
● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
● Module swapping during operation (hot swapping) | Yes; Multi-hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping |
● Isochronous mode | Yes | Yes | Yes | No |
● Tool changer | Yes; Docking station and docking unit | Yes; Docking station and docking unit | ||
● Local coupling, IO data | No | Yes | ||
— Number of coupling modules | 16 | |||
— Number of coupling submodules per module | 4 | |||
● Local coupling, data records | No | No | ||
Engineering with | ||||
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V15.1 or higher | V15.1 | STEP 7 V14 or higher | V15 SP1 |
● STEP 7 configurable/integrated from version | Configurable via GSD file | Configurable via GSD file | V5.5 SP4 and higher | As of V5.5 SP4, only up to FW V3.1 |
● PROFIBUS from GSD version/GSD revision | One GSD file each, Revision 3 and 5 and higher | |||
● PROFINET from GSD version/GSD revision | GSDML V2.3 | GSDML V2.3 | – / V2.3 | |
Configuration control | ||||
via dataset | Yes | Yes | Yes | Yes |
Supply voltage | ||||
Rated value (DC) | 24 V | 24 V | 24 V | 24 V |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | 19.2 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
Reverse polarity protection | Yes | Yes | Yes | Yes |
Mains buffering | ||||
● Mains/voltage failure stored energy time | 10 ms | 10 ms | 5 ms | 10 ms |
Input current | ||||
Current consumption (rated value) | 175 mA; At 24 V, 2 slots 2x RJ45 BusAdapter, no I/O modules | |||
Current consumption, max. | 700 mA | 950 mA | 500 mA | 335 mA |
Inrush current, max. | 4.5 A | 9 A | 4.5 A | 1.6 A |
I²t | 0.25 A²·s | 0.34 A²·s | 0.09 A²·s | 0.038 A²·s |
Power loss | ||||
Power loss, typ. | 2.4 W | 4.9 W | 1.7 W | 1.5 W |
Address area | ||||
Address space per module | ||||
● Address space per module, max. | 288 byte; For input and output data respectively | 288 byte; For input and output data respectively | 32 byte; For input and output data respectively | 32 byte; per input / output |
Address space per station | ||||
● Address space per station, max. | 1 440 byte; Dependent on configuration | 1 440 byte; Dependent on configuration | 968 byte; For input and output data respectively | 244 byte; per input / output |
Hardware configuration | ||||
Rack | ||||
● Quantity of operable ET 200SP modules, max. | 64 | 64 | 30 | 32 |
● Quantity of operable ET 200AL modules, max. | 16 | 16 | 0 | 16 |
Submodules | ||||
● Number of submodules per station, max. | 256 | 256 | 125 | |
Time stamping | ||||
Accuracy | 10 ms | |||
Interfaces | ||||
Number of PROFINET interfaces | 1; 2 ports (switch) | 1; 3 ports (switch) | 1; 2 ports (switch) | |
Number of PROFIBUS interfaces | 1 | |||
1. Interface | ||||
Interface types | ||||
● RS 485 | Yes | |||
● Number of ports | 2; via BusAdapter | 3; Via 2 BusAdapter slots | 2 | |
● integrated switch | Yes | Yes | Yes | |
● BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC, | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | |
● Output current of the interface, max. | 90 mA | |||
Protocols | ||||
● PROFINET IO Device | Yes | Yes | Yes | |
● PROFIBUS DP slave | Yes | |||
● Open IE communication | Yes | Yes | Yes | |
● Media redundancy | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; As MRP or MRPD client; max. 50 or 30 devices in the ring | |
Interface types | ||||
RJ 45 (Ethernet) | ||||
● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
● 10 Mbps | No | No | No | |
● 100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
● Autonegotiation | Yes | Yes | Yes | |
● Autocrossing | Yes | Yes | Yes | |
RS 485 | ||||
● Transmission rate, max. | 12 Mbit/s | |||
Protocols | ||||
Number of connections | ||||
● Number of MtM communication relationships/connections, max. | 16 | 16 | ||
PROFINET IO Device | ||||
Services | ||||
— IRT | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; 125 µs, 250 µs, 500 µs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | |
— PROFIenergy | Yes | Yes | Yes | |
— Prioritized startup | Yes | Yes | Yes | |
— Shared device | Yes | Yes | Yes | |
— Number of IO Controllers with shared device, max. | 4 | 4 | 4 | |
Redundancy mode | ||||
● PROFINET system redundancy (S2) | Yes; NAP S2 | Yes; NAP S2 | No | |
● Redundant PROFINET configuration (R1) | No | |||
● H-Sync forwarding | Yes | Yes | ||
Media redundancy | ||||
— MRP | Yes | Yes | Yes | |
— MRPD | No | No | Yes | |
Open IE communication | ||||
● TCP/IP | Yes | Yes | Yes | No |
● SNMP | Yes | Yes | Yes | |
● LLDP | Yes | Yes | Yes | |
PROFIBUS DP | ||||
Services | ||||
— SYNC capability | Yes | |||
— FREEZE capability | Yes | |||
— DPV0 | Yes | |||
— DPV1 | Yes | |||
Isochronous mode | ||||
Equidistance | Yes | Yes | Yes | |
shortest clock pulse | 250 µs | 250 µs | 125 µs | |
max. cycle | 4 ms | 4 ms | 4 ms | |
Bus cycle time (TDP), min. | 250 µs | 250 µs | 125 µs | |
Jitter, max. | 1 µs | 1 µs | 0.25 µs | |
Interrupts/diagnostics/status information | ||||
Status indicator | Yes | Yes | Yes | Yes |
Alarms | Yes | Yes | Yes | Yes |
Diagnostics function | Yes | Yes | Yes | Yes |
Diagnostics indication LED | ||||
● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED |
● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED |
● MAINT LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED |
● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED |
● Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | |
● Connection display DP | Yes; green DP LED | |||
Potential separation | ||||
between backplane bus and electronics | No | No | No | No |
between PROFIBUS DP and all other circuit components | Yes | |||
between PROFINET and all other circuits | Yes | Yes | Yes | |
between supply and all other circuits | No | No | No | No |
Permissible potential difference | ||||
between different circuits | Safety extra low voltage SELV | |||
Isolation | ||||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC between supply voltage and electronics (type test); 1 500 V AC between Ethernet and electronics (type test) | 707 V DC (type test) |
Standards, approvals, certificates | ||||
Network loading class | 3 | 3 | 3 | |
Security level | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | |
Ambient conditions | ||||
Ambient temperature during operation | ||||
● horizontal installation, min. | -30 °C; No condensation | -30 °C | -25 °C; No condensation | -25 °C |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | 60 °C |
● vertical installation, min. | -30 °C; No condensation | -30 °C | -25 °C; No condensation | -25 °C |
● vertical installation, max. | 50 °C | 50 °C | 50 °C | 50 °C |
Altitude during operation relating to sea level | ||||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
connection method / header | ||||
ET-Connection | ||||
● via BU/BA Send | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | No | Yes; + 16 ET 200AL modules |
Mechanics/material | ||||
Strain relief | Yes; Optional | Yes; Optional | ||
Dimensions | ||||
Width | 50 mm | 100 mm | 50 mm | 50 mm |
Height | 117 mm | 117 mm | 117 mm | 117 mm |
Depth | 74 mm | 74 mm | 74 mm | 74 mm |
Weights | ||||
Weight, approx. | 120 g; without BusAdapter | 220 g; without BusAdapter | 147 g; without BusAdapter | 150 g |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details