SIMATIC ET 200SP – BU Type A1 – Siemens Base Units
USD $ 33.44 – USD $ 51.04
SKU: N/A
With the BaseUnits (BUs), the ET 200SP offers a rugged and service-friendly design with permanent wiring:
- No tools needed for one-handed wiring using push-in terminals
- Actuation of the spring NC contacts with a standard screwdriver, with a blade width up to 3.5 mm
- Outstanding access due to arrangement of measuring tap, spring NC contacts and cable entry in columns, while at the same time reducing the space required by 64%
- Fault-proof color coding of the spring NC contacts for better orientation in the terminal panel
- Replacement of I/O modules during operation without affecting the wiring
- Operation with module gaps (gaps without I/O module)
- Automatic coding of the I/O modules prevents destruction of the electronics if a module is accidentally inserted in the wrong slot during replacement
- High EMC interference immunity:
- self-assembling shielded backplane bus
- multi-layer conductor plate with shield levels for interference-free signal transmission from the terminal to the I/O module
- system-integrated, space-saving shield connection for quick installation
- Self-assembling potential groups without external wiring or jumpers
- Replaceable terminal box
- Side-by-side latching of the BUs for high mechanical and EMC loads
- Optional module-specific color identification of the terminals according to the color code CC
- Optional equipment marking using slide-in equipment labeling plates
An ET 200SP station can be expanded via one ‘BU-Send’ BaseUnit with a “BA-Send” BusAdapter plugged onto it with up to 16 modules from the ET 200AL series of I/O devices with IP67 protection.
Siemens BaseUnit ET 200SP Product Specifications:
Article number | 6ES7193-6BP40-0DA1 | 6ES7193-6BP00-0DA1 | 6ES7193-6BP40-0BA1 | 6ES7193-6BP00-0BA1 |
BaseUnit Type A1, BU15-P16+A0+12D/T | BaseUnit Type A1, BU15-P16+A0+2D/T | BaseUnit Type A1, BU15-P16+A0+12B/T | BaseUnit Type A1, BU15-P16+A0+2B/T | |
General information | ||||
Product type designation | BU type A1 | BU type A1 | BU type A1 | BU type A1 |
HW functional status | FS10 and higher | FS10 and higher | FS10 and higher | FS10 and higher |
Supply voltage | ||||
Rated value (DC) | 24 V | 24 V | 24 V | 24 V |
external protection for power supply lines | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic |
Current carrying capacity | ||||
For P1 and P2 bus, max. | 10 A | 10 A | 10 A | 10 A |
For process terminals, max. | 2 A | 2 A | 2 A | 2 A |
Hardware configuration | ||||
Additional terminals | Yes | Yes | ||
Temperature sensor | Yes | Yes | Yes | Yes |
Formation of potential groups | ||||
● New potential group | Yes | Yes | No | No |
● Potential group continued from the left | No | No | Yes | Yes |
Slots | ||||
● Number of slots | 1; Type A1 | 1; Type A1 | 1; Type A1 | 1; Type A1 |
Potential separation | ||||
between the potential groups | Yes | Yes | ||
Isolation | ||||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) |
Ambient conditions | ||||
Ambient temperature during operation | ||||
● horizontal installation, min. | -30 °C | -30 °C | -30 °C | -30 °C |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | 60 °C |
● vertical installation, min. | -30 °C | -30 °C | -30 °C | -30 °C |
● vertical installation, max. | 50 °C | 50 °C | 50 °C | 50 °C |
Altitude during operation relating to sea level | ||||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Accessories | ||||
Color coding labels | ||||
● for process terminals | CC00 to CC09 | CC00 to CC09 | CC00 to CC09 | CC00 to CC09 |
● for AUX terminals | does not exist | does not exist | does not exist | does not exist |
● for add-on terminals | CC74 | does not exist | CC74 | does not exist |
connection method / header | ||||
Terminals | ||||
● Terminal type | Push-in terminal | Push-in terminal | Push-in terminal | Push-in terminal |
● Conductor cross-section, min. | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 | 0.14 mm²; AWG 26 |
● Conductor cross-section, max. | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 | 2.5 mm²; AWG 14 |
● Number of process terminals to I/O module | 16 | 16 | 16 | 16 |
● Number of terminals to AUX bus | 0 | 0 | 0 | 0 |
● Number of add-on terminals | 2×5 | 0 | 2×5 | 0 |
● Number of terminals with connection to P1 and P2 bus | 2 | 2 | 2 | 2 |
Dimensions | ||||
Width | 15 mm | 15 mm | 15 mm | 15 mm |
Height | 141 mm | 117 mm | 141 mm | 117 mm |
Depth | 35 mm | 35 mm | 35 mm | 35 mm |
Weights | ||||
Weight, approx. | 50 g | 40 g | 50 g | 40 g |