USD $ 50.60 – USD $ 549.01
Article number | 6ES7132-4BB01-0AB0 | 6ES7132-4BB01-0AA0 | 6ES7132-4BB31-0AB0 | 6ES7132-4BB31-0AA0 | 6ES7132-4BD00-0AB0 | 6ES7132-4BD02-0AA0 |
ET200S, El-Mod., 2DO HF,DC24V, 0.5A, 5PC | ET200S, El-Mod., 2DO ST,DC24V, 0.5A, 5PC | ET200S, El-Mod., 2DO HF, DC 24V, 2A, 5PC | ET200S, El-Mod., 2DO ST, DC 24V, 2A, 5PC | ET200S, El-Mod., 4DO HF,DC24V, 0.5A,5pcs | ET200S, El-Mod., 4DO ST,DC24V, 0.5A,5pcs | |
Supply voltage | ||||||
Reverse voltage protection | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module |
Load voltage L+ | ||||||
● Rated value (DC) | 24 V; From power module | 24 V; From power module | 24 V; From power module | 24 V; From power module | 24 V; From power module | 24 V; From power module |
● Reverse polarity protection | Yes; polarity reversal can lead to the digital outputs being connected through | Yes; polarity reversal can lead to the digital outputs being connected through | Yes; polarity reversal can lead to the digital outputs being connected through | Yes; polarity reversal can lead to the digital outputs being connected through | Yes; polarity reversal can lead to the digital outputs being connected through | Yes; polarity reversal can lead to the digital outputs being connected through |
Input current | ||||||
from load voltage L+ (without load), max. | 5 mA; Per channel | 5 mA; Per channel | 5 mA; Per channel | 5 mA; Per channel | 5 mA; Per channel | 10 mA; Per channel |
from backplane bus 3.3 V DC, max. | 10 mA | 10 mA | 10 mA | 10 mA | 10 mA | 10 mA |
Power loss | ||||||
Power loss, typ. | 0.4 W | 0.4 W | 1.4 W | 1.4 W | 0.8 W | 0.8 W |
Address area | ||||||
Address space per module | ||||||
● Address space per module, max. | 1 byte | 1 byte | 1 byte | 1 byte | 1 byte | 1 byte |
● with packing | 2 bit | 2 bit | 2 bit | 2 bit | 4 bit | 4 bit |
Digital outputs | ||||||
Type of digital output | Source output (PNP, current-sourcing) | Source output (PNP, current-sourcing) | Source output (PNP, current-sourcing) | Source output (PNP, current-sourcing) | Transistor | Source output (PNP, current-sourcing) |
Number of digital outputs | 2 | 2 | 2 | 2 | 4 | 4 |
Short-circuit protection | Yes | Yes | Yes | Yes | Yes | Yes |
● Response threshold, typ. | 1.5 A | 0.7 to 1.8 A | 4 A | 2.8 to 7.2 A | 0.7 to 1.5 A | 1 to 1.5 A |
Limitation of inductive shutdown voltage to | -55 to -60 V, typ. L+( ) | -55 to -60 V, typ. L+( ) | -55 to -60 V, typ. L+( ) | -55 to -60 V, typ. L+( ) | -55 to -60 V, L+( ) | L+ (-55 to -60 V) |
Controlling a digital input | Yes | Yes | Yes | Yes | Yes | Yes |
Switching capacity of the outputs | ||||||
● on lamp load, max. | 2.5 W | 5 W | 5 W | 10 W | 5 W | 5 W |
Load resistance range | ||||||
● lower limit | 48 Ω | 48 Ω | 12 Ω | 12 Ω | 48 Ω | 48 Ω |
● upper limit | 3 400 Ω | 3 400 Ω | 3 400 Ω | 3 400 Ω | 3 400 Ω | 3 400 Ω |
Output voltage | ||||||
● for signal “1”, min. | L+ (-1 V) | L+ (-1 V) | L+ (-1 V) | L+ (-1 V) | L+ (-1 V) | L+ (-1 V) |
Output current | ||||||
● for signal “1” rated value | 0.5 A | 0.5 A | 2 A | 2 A | 0.5 A | 0.5 A |
● for signal “1” permissible range, min. | 7 mA | 7 mA | 7 mA | 7 mA | 7 mA | 7 mA |
● for signal “1” permissible range, max. | 600 mA | 600 mA | 2.4 A | 2.4 A | 600 mA | 600 mA |
● for signal “0” residual current, max. | 0.3 mA | 0.3 mA | 0.5 mA | 0.5 mA | 0.3 mA | 0.3 mA |
Output delay with resistive load | ||||||
● “0” to “1”, max. | 100 µs | 200 µs | 100 µs | 200 µs | 100 µs | 50 µs |
● “1” to “0”, max. | 400 µs | 1.3 ms | 400 µs | 1.3 ms | 300 µs | 120 µs |
Parallel switching of two outputs | ||||||
● for uprating | No | No | No | No | No | No |
● for redundant control of a load | Yes; per module | Yes; per module | Yes; per module | Yes; per module | Yes; per module | Yes; per module |
Switching frequency | ||||||
● with resistive load, max. | 100 Hz | 100 Hz | 100 Hz | 100 Hz | 100 Hz | 800 Hz |
● with inductive load, max. | 2 Hz | 2 Hz | 2 Hz; 0,5 H | 2 Hz; 0,5 H | 2 Hz | 2 Hz |
● on lamp load, max. | 10 Hz | 10 Hz | 10 Hz | 10 Hz | 10 Hz | 10 Hz |
Total current of the outputs | ||||||
● Current per module, max. | 1 A | 1 A | 4 A | 4 A | 2 A | 2 A |
Cable length | ||||||
● shielded, max. | 1 000 m | 1 000 m | 1 000 m | 1 000 m | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m | 600 m | 600 m | 600 m | 600 m |
Interrupts/diagnostics/status information | ||||||
Diagnostics function | Yes | No | Yes | No | Yes | No |
Substitute values connectable | Yes; 0/1 | Yes; 0/1 | ||||
Diagnoses | ||||||
● Diagnostic information readable | Yes | Yes | ||||
● Wire-break | Yes; channel by channel | Yes; channel by channel | ||||
● Short-circuit | Yes; channel by channel | Yes; channel by channel | Yes; Module-wise | |||
Diagnostics indication LED | ||||||
● Group error SF (red) | Yes | Yes | Yes | |||
● Status indicator digital output (green) | Yes | Yes | Yes | Yes | Yes; Per channel | Yes |
Parameter | ||||||
Remark | 3 byte | 1 byte | 3 byte | 1 byte | 3 byte | 1 byte |
Diagnostics wire break | Disable / enable | Disable / enable | ||||
Diagnostics short-circuit | Disable / enable | Disable / enable | ||||
Response to CPU/master STOP | Substitute a value/keep last value | Substitute a value/keep last value | ||||
Potential separation | ||||||
Potential separation digital outputs | ||||||
● between the channels | No | No | No | No | No | No |
● between the channels and backplane bus | Yes | Yes | Yes | Yes | Yes | Yes |
Isolation | ||||||
Isolation tested with | 500 V DC | 500 V DC | 500 V DC | 500 V DC | 500 V DC | 500 V DC |
Dimensions | ||||||
Width | 15 mm | 15 mm | 15 mm | 15 mm | 15 mm | 15 mm |
Height | 81 mm | 81 mm | 81 mm | 81 mm | 81 mm | 81 mm |
Depth | 52 mm | 52 mm | 52 mm | 52 mm | 52 mm | 52 mm |
Weights | ||||||
Weight, approx. | 40 g | 40 g | 40 g | 40 g | 40 g | 40 g |
Article number | 6ES7132-4BF00-0AB0 | 6ES7132-4BF00-0AA0 | 6ES7132-4BF50-0AA0 |
ET200S, Electr.Module 8DO HF DC24V/0,5A | ET200S, Electr. Module 8DO DC24V/0,5A | ET200S, 8DO Sink Output DC24V/0,5A | |
Supply voltage | |||
Reverse voltage protection | Yes; when using the same load voltage as on the power module | Yes | Yes; when using the same correctly polarized load voltage as on the power module |
Load voltage L+ | |||
● Rated value (DC) | 24 V; From power module | 24 V | 24 V; From power module |
● Reverse polarity protection | Yes; polarity reversal can lead to the digital outputs being connected through | Yes | Yes |
Input current | |||
from load voltage L+ (without load), max. | 5 mA; Per channel | 5 mA; Per channel | 5 mA |
from backplane bus 3.3 V DC, max. | 10 mA | 10 mA | 10 mA |
Power loss | |||
Power loss, typ. | 1.5 W | 1.5 W | 1.5 W |
Address area | |||
Address space per module | |||
● Address space per module, max. | 1 byte | 1 byte | 1 byte |
Digital outputs | |||
Type of digital output | Source output (PNP, current-sourcing) | Source output (PNP, current-sourcing) | Transistor |
Number of digital outputs | 8 | 8 | 8 |
Short-circuit protection | Yes | Yes | Yes |
● Response threshold, typ. | 0.7 to 1.9 A | 1.5 A | 1.5 A |
Limitation of inductive shutdown voltage to | L+ -(47 to 60 V) | Typ. L+ (-55 to -60 V) | Typ. 47 V |
Controlling a digital input | Yes | Yes | Yes |
Switching capacity of the outputs | |||
● on lamp load, max. | 5 W | 5 W | 5 W |
Load resistance range | |||
● lower limit | 48 Ω | 48 Ω | 48 Ω |
● upper limit | 3 400 Ω | 3 400 Ω | 3 400 Ω |
Output voltage | |||
● for signal “1”, min. | L+ (-1.0 V) | L+ (-1.0 V) | Max. 1 V |
Output current | |||
● for signal “1” rated value | 0.5 A | 0.5 A | 0.5 A |
● for signal “1” permissible range, min. | 7 mA | 7 mA | 5 mA |
● for signal “1” permissible range, max. | 600 mA | 600 mA | 600 mA |
● for signal “0” residual current, max. | 0.3 mA | 0.3 mA | 5 µA |
Output delay with resistive load | |||
● “0” to “1”, max. | 300 µs | 300 µs | 300 µs |
● “1” to “0”, max. | 600 µs | 600 µs | 600 µs |
Parallel switching of two outputs | |||
● for uprating | No | No | No |
● for redundant control of a load | Yes; per module | Yes | Yes; per module |
Switching frequency | |||
● with resistive load, max. | 100 Hz | 100 Hz | 100 Hz |
● with inductive load, max. | 2 Hz | 2 Hz | 0.5 Hz |
● on lamp load, max. | 10 Hz | 10 Hz | 10 Hz |
Total current of the outputs | |||
● Current per module, max. | 4 A | 4 A | 4 A |
Cable length | |||
● shielded, max. | 1 000 m | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m | 600 m |
Interrupts/diagnostics/status information | |||
Diagnostics function | Yes | No | No |
Diagnoses | |||
● Diagnostic information readable | Yes | ||
● Short-circuit | Yes; Module-wise | ||
Diagnostics indication LED | |||
● Group error SF (red) | Yes | ||
● Status indicator digital output (green) | Yes; Per channel | Yes | Yes |
Parameter | |||
Remark | 1 byte | 3-byte parameter (not accessible for the user) | 3 byte |
Potential separation | |||
Potential separation digital outputs | |||
● between the channels | No | No | No |
● between the channels and backplane bus | Yes | Yes | Yes |
Isolation | |||
Isolation tested with | 500 V DC | 500 V DC | 500 V DC |
Dimensions | |||
Width | 15 mm | 15 mm | 15 mm |
Height | 81 mm | 81 mm | 81 mm |
Depth | 52 mm | 52 mm | 52 mm |
Weights | |||
Weight, approx. | 40 g | 40 g | 40 g |
Article number | 6ES7132-4BD30-0AB0 | 6ES7132-4BD32-0AA0 | 6ES7132-4FB01-0AB0 | 6ES7132-4HB01-0AB0 | 6ES7132-4HB13-0AB0 |
ET200S, El-Mod., 4DO HF, DC24V, 2A, 5pcs | ET200S, El-Mod., 4DO ST, DC24V, 2A, 5pcs | ET200S, Elect. Mod., 2DO, AC 230V, 5pcs | ET200S, El-Mod., 2RO. DC24VAC230V,5A,5PC | ET200S, El-Mod., 2RO,DC48V/AC230V,5A,5PC | |
Supply voltage | |||||
Reverse voltage protection | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | Yes; when using the same load voltage as on the power module | ||
Load voltage L+ | |||||
● Rated value (DC) | 24 V; From power module | 24 V; From power module | 24 V; From power module | 24 V; From power module | |
● Reverse polarity protection | Yes; polarity reversal can lead to the digital outputs being connected through | Yes | Yes | Yes | |
Load voltage L1 | |||||
● permissible range, lower limit (AC) | 24 V; From power module | ||||
● permissible range, upper limit (AC) | 230 V | ||||
● permissible frequency range, lower limit | 47 Hz | ||||
● permissible frequency range, upper limit | 63 Hz | ||||
Input current | |||||
from load voltage L+ (without load), max. | 5 mA; Per channel | 10 mA; Per channel | 30 mA | 30 mA | |
from load voltage L1 (without load), max. | 15 mA; Per channel | ||||
from backplane bus 3.3 V DC, max. | 10 mA | 10 mA | 18 mA | 10 mA | 10 mA |
Power loss | |||||
Power loss, typ. | 1.6 W | 1.6 W | 0.6 W | 0.6 W | |
Power loss, max. | 4 W | ||||
Address area | |||||
Address space per module | |||||
● Address space per module, max. | 1 byte | 1 byte | 1 byte | 1 byte | 1 byte |
● with packing | 4 bit | 4 bit | 2 bit | 2 bit | 2 bit |
Digital outputs | |||||
Type of digital output | Transistor | Source output (PNP, current-sourcing) | Triac | Relays | Relays |
Number of digital outputs | 4 | 4 | 2 | 2 | 2 |
Short-circuit protection | Yes | Yes | Yes | No | No; The relay outputs must be fused externally with 6 A. When installing in a hazardous area in accordance with the National Electric Code (NEC), the fuse may only be removed using a suitable tool if the module is not in the hazardous area. |
● Response threshold, typ. | 5 to 10 A | 2.8 to 7.2 A | |||
Limitation of inductive shutdown voltage to | L+ -(37 to 41V) | Typ. L+ (-55 to -60 V) | -55 to -60 V | No | No |
Controlling a digital input | Yes | Yes | Yes; possible | Yes | Yes |
Switching capacity of the outputs | |||||
● on lamp load, max. | 10 W | 100 W | |||
Load resistance range | |||||
● lower limit | 12 Ω | 12 Ω | |||
● upper limit | 3 400 Ω | 3 400 Ω | |||
Output voltage | |||||
● for signal “1”, min. | L+ (-1.0 V) | L+ (-1.0 V) | L+ (-1.5 V) | ||
Output current | |||||
● for signal “1” rated value | 2 A | 2 A | 2 A | 5 A | 5 A; See data in manual |
● for signal “1” permissible range, min. | 7 mA | 7 mA | 0.1 mA | ||
● for signal “1” permissible range, max. | 2.4 A | 2.4 A | 2.2 A | ||
● for signal “1” minimum load current | 8 mA | 8 mA | |||
● for signal “0” residual current, max. | 0.5 mA | 0.1 mA | 3 mA | ||
Output delay with resistive load | |||||
● “0” to “1”, max. | 250 µs | 50 µs; Typ. 45 µs | 15 ms | ||
● “1” to “0”, max. | 400 µs | 120 µs; Typ. 90 µs | 15 ms | ||
Parallel switching of two outputs | |||||
● for uprating | No | No | No | ||
● for redundant control of a load | Yes; per module | Yes; per module | Yes; per module | ||
Switching frequency | |||||
● with resistive load, max. | 100 Hz | 1 000 Hz | 10 Hz | 2 Hz | 2 Hz |
● with inductive load, max. | 2 Hz | 2 Hz; At 0.5 H | 0.5 Hz | 0.5 Hz | 0.5 Hz |
● on lamp load, max. | 10 Hz | 10 Hz | 1 Hz | 2 Hz | 2 Hz |
Total current of the outputs | |||||
● Current per module, max. | 4 A | 4 A | 2 A; note derating data in the manual | ||
Total current of the outputs (per group) | |||||
horizontal installation | |||||
— up to 50 °C, max. | 5 A; per channel | ||||
— up to 60 °C, max. | 4 A; per channel | ||||
vertical installation | |||||
— up to 40 °C, max. | 5 A; per channel | ||||
Relay outputs | |||||
Switching capacity of contacts | |||||
— Thermal continuous current, max. | 5 A | 5 A; See data in manual | |||
Cable length | |||||
● shielded, max. | 1 000 m | 1 000 m | 1 000 m | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m | 600 m | 600 m | 600 m |
Interrupts/diagnostics/status information | |||||
Diagnostics function | Yes | No | No | No | No |
Substitute values connectable | Yes; 0/1 | Yes; 0/1 | |||
Diagnoses | |||||
● Short-circuit | Yes; Module-wise | ||||
Diagnostics indication LED | |||||
● Group error SF (red) | Yes; SF-LED (red) | ||||
● Status indicator digital output (green) | Yes; Per channel | Yes | Yes | Yes | Yes |
Parameter | |||||
Remark | 1 byte | 3 byte | |||
Response to CPU/master STOP | Substitute a value/keep last value, 0/1 | Substitute a value/keep last value | Substitute a value/keep last value | ||
Potential separation | |||||
Potential separation digital outputs | |||||
● between the channels | No | No | No | Yes | Yes |
● between the channels and backplane bus | Yes | Yes | Yes | Yes | Yes |
● Between the channels and load voltage L+ | Yes | Yes | |||
Isolation | |||||
Isolation tested with | 500 V DC | 500 V DC | 2 500 V DC | ||
Ambient conditions | |||||
Altitude during operation relating to sea level | |||||
● Ambient air temperature-barometric pressure-altitude | Tmin … Tmax at 1 080 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax – 20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) | Up to max. 2 000 m | |||
Dimensions | |||||
Width | 15 mm | 15 mm | 15 mm | 15 mm | 15 mm |
Height | 81 mm | 81 mm | 81 mm | 81 mm | 81 mm |
Depth | 52 mm | 52 mm | 52 mm | 52 mm | 52 mm |
Weights | |||||
Weight, approx. | 40 g | 40 g | 37 g | 50 g | 50 g |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)
inosaki.com 2008 -2024