The IM 153-1 / IM 153-2 HF interface modules are required to connect the modular I/O device ET 200M to the PROFIBUS DP fieldbus.
These heads can be used in many different applications.
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Article number | 6ES7153-2BA10-0XB0 | |
ET200M, Interface IM153-2 HF | ||
General information | ||
Product type designation | IM 153-2 DP HF | |
Firmware version | V6.0.0 | |
Vendor identification (VendorID) | 801Eh | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
external protection for power supply lines (recommendation) | 2,5 A | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption, max. | 650 mA; with 24 V DC supply | |
Inrush current, typ. | 3 A | |
I²t | 0.1 A²·s | |
output voltage / header | ||
Rated value (DC) | ||
Output current | ||
for backplane bus (5 V DC), max. | 1.5 A | |
Power loss | ||
Power loss, typ. | 5.5 W | |
Address area | ||
Addressing volume | ||
● Inputs | 244 byte | |
● Outputs | 244 byte | |
Hardware configuration | ||
Number of modules per DP slave interface, max. | 12 | |
Time stamping | ||
Accuracy | 1 ms; 1 ms at up to 8 modules; 10 ms at up to 12 modules | |
Number of message buffers | 15 | |
Messages per message buffer | 20 | |
Number of stampable digital inputs, max. | 128; Max. 128 signals/station; max. 32 signals/slot | |
Time format | RFC 1119 | |
Time resolution | 0.466 ns | |
Time interval for transmitting the message buffer if a message is present | 1 000 ms | |
Time stamp on signal change | rising / falling edge as signal entering or exiting | |
Interfaces | ||
Transmission procedure | RS 485 | |
Transmission rate, max. | 12 Mbit/s | |
1. Interface | ||
automatic detection of transmission rate | Yes | |
Interface types | ||
● Output current of the interface, max. | 70 mA | |
● Design of the connection | 9-pin sub D socket | |
PROFIBUS DP slave | ||
● GSD file | SI05801E.GSG | |
● automatic baud rate search | Yes | |
Protocols | ||
Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 | |
Protocols (Ethernet) | ||
● TCP/IP | No | |
PROFIBUS DP | ||
● Number of node addresses, max. | 1 to 125 permitted | |
Services | ||
— SYNC capability | Yes | |
— FREEZE capability | Yes | |
— Direct data exchange (slave-to-slave communication) | Yes; as publisher with all IO, as subscriber with F-IO only | |
Potential separation | ||
Potential separation exists | Yes | |
Isolation | ||
Isolation tested with | Isolation voltage 500 V | |
Degree and class of protection | ||
IP degree of protection | IP20 | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | 0 °C | |
● max. | 60 °C | |
● horizontal installation, min. | 0 °C | |
● horizontal installation, max. | 60 °C | |
● vertical installation, min. | 0 °C | |
● vertical installation, max. | 40 °C | |
Altitude during operation relating to sea level | ||
● Installation altitude above sea level, max. | 3 000 m | |
configuration / header | ||
Configuration software | ||
● STEP 7 | Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file | |
Dimensions | ||
Width | 40 mm | |
Height | 125 mm | |
Depth | 117 mm | |
Weights | ||
Weight, approx. | 360 g |
[/fusion_table]
Weight | 0.284 kg |
---|---|
Dimensions | 12.8 × 14.9 × 5.2 cm |