$ 610.42 – $ 879.98
Item | Specifications | |
Product Number | SF2C-H24-N | SF2C-H12-N |
Part Number | SF2C-H24-N | SF2C-H12-N |
No. of beam channels | 24 | 12 |
Protective height | 480 mm 18.898 in | 240 mm 9.449 in |
Current consumption:Large multipurpose indicator lights off | Emitter: 35 mA or less Receiver: 35 mA or less |
Emitter: 30 mA or less Receiver: 30 mA or less |
Current consumption:Large multipurpose indicator lights up | Emitter: 45 mA or less Receiver: 40 mA or less |
Emitter: 35 mA or less Receiver: 35 mA or less |
PFHD | 3.99 × 10-9 (Note) Probability of dangerous failure per hour. |
3.80 × 10-9 (Note) Probability of dangerous failure per hour. |
MTTFD | 100 years or more (Note) Mean time to dangerous failure. |
100 years or more (Note) Mean time to dangerous failure. |
Net weight (Total of emitter and receiver) | 520 g approx. | 340 g approx. |
Applicable standards:International standard | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) |
Applicable standards:Japan | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) |
Applicable standards:Europe | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
Applicable standards:North America | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. |
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. |
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification |
Operating range | 0.1 to 3 m 0.328 to 9.843 ft | 0.1 to 3 m 0.328 to 9.843 ft |
Beam pitch | 20 mm 0.787 in | 20 mm 0.787 in |
Min. sensing object | ø25 mm ø0.984 in opaque object | ø25 mm ø0.984 in opaque object |
Effective aperture angle | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
Power voltage | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
Control output(OSSD) | – Maximum sink current: 200mA – Applied voltage: same as supply voltage (between the control output and -0V) – Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) – Leakage current: 200micro A or less (power supply OFF condition) – Maximum load capacity: 2.2micro F (No load to maximum output current) – Load wiring resistance: 3Ω or less |
– Maximum sink current: 200mA – Applied voltage: same as supply voltage (between the control output and -0V) – Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) – Leakage current: 200micro A or less (power supply OFF condition) – Maximum load capacity: 2.2micro F (No load to maximum output current) – Load wiring resistance: 3Ω or less |
Control output(OSSD):Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
Control output(OSSD):Protection circuit | Incorporated | Incorporated |
Response time | OFF response: 20 ms or less ON response: 80 to 100 ms |
OFF response: 20 ms or less ON response: 80 to 100 ms |
Lockout output(SSD) | – Maximum sink current: 60mA – Applied voltage: same as supply voltage (between the lockout output and -0V) – Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) – Leakage current: 200micro A or less (power supply OFF condition) – Maximum load capacity: 2.2micro F (No load to maximum output current) – Load wiring resistance: 3Ω or less |
– Maximum sink current: 60mA – Applied voltage: same as supply voltage (between the lockout output and -0V) – Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) – Leakage current: 200micro A or less (power supply OFF condition) – Maximum load capacity: 2.2micro F (No load to maximum output current) – Load wiring resistance: 3Ω or less |
Lockout output(SSD):Operation mode | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
Lockout output(SSD):Protection circuit | Incorporated | Incorporated |
Interference prevention function | Incorporated | Incorporated |
Test input function | Incorporated | Incorporated |
Large multi-purpose indicator function | Incorporated | Incorporated |
Pollution degree | 3 | 3 |
Operating altitude | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
Environmental resistance:Degree of protection | IP65, IP67 (IEC) | IP65, IP67 (IEC) |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: – 25 to +60 ℃ – 13 to +140 ℉ | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: – 25 to +60 ℃ – 13 to +140 ℉ |
Environmental resistance:Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | 30 to 85 % RH, Storage: 30 to 85 % RH |
Ambient illuminance | Incandescent light: 5,000 ℓx or less at the light-receiving face | Incandescent light: 5,000 ℓx or less at the light-receiving face |
Environmental resistance:Voltage withstandability | 1, 000 V AC for one min. between all supply terminals connected together and enclosure | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
Environmental resistance:Insulation resistance | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Environmental resistance:Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance:Shock resistance | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) |
Cable | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long |
Cable extension | Extension up to total 50m is possible for 0.3mm2 or more, cable | Extension up to total 50m is possible for 0.3mm2 or more, cable |
Material | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
Accessories | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. |
MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)