Contact Us:
sales@inosaki.com

QUINT-PS/2AC/1DC/24DC/20 – 2320830 – Phoenix Contact Power Supply

$ 190.90

SKU Phoenix Contact 2320830 Category

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my

Product Description

QUINT POWER power supply units – Superior system availability with SFB technology
Compact power supply units of the new QUINT POWER generation maximize the availability of your system. With the SFB technology (Selective Fuse Breaking Technology), six times the nominal current for 12 ms, even the standard power circuit-breakers can now also be triggered reliably and quickly. Faulty current paths are switched off selectively, the fault is located and important system parts continue to operate. Comprehensive diagnostics are provided through constant monitoring of output voltage and current. This preventive function monitoring visualizes critical operating modes and reports them to the control unit before an error can occur.

Dimensions

Article Number 2320830
Width 120 mm
Height 130 mm
Depth 125 mm
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 2000 m

 

Input data

Nominal input voltage range 2x 400 V AC … 500 V AC
600 V DC
Input voltage range 2x 360 V AC … 575 V AC
450 V DC … 840 V DC
AC frequency range 45 Hz … 65 Hz
Frequency range DC 0 Hz
Current consumption 2.5 A (400 V AC)
2.1 A (500 V AC)
Nominal power consumption 888 VA
Inrush current < 45 A (typical)
Mains buffering time typ. 20 ms (400 V AC)
Input fuse 3.15 A (slow-blow, internal)
Recommended breaker for input protection 10 A … 16 A (Characteristic B, C)
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 18 V DC … 29.5 V DC (UIN ≥ 360 V AC / 480 V DC)
18 V DC … 26 V DC (< 480 V DC)
Nominal output current (IN) 20 A (-25 °C … 60 °C)
POWER BOOST (IBoost) 26 A (-25 °C … 40 °C permanent, UOUT = 24 V DC )
Selective Fuse Breaking (ISFB) 120 A (20 ms)
Derating 60 °C … 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance < 35 V DC
Protection against overvoltage at the output (OVP) < 35 V DC
Max. capacitive load unlimited
Active current limitation Approx. 27 A
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 2 % (change in load, dynamic 10 % … 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values)
Output power 480 W
Peak switching voltages nominal load < 50 mVPP (20 MHz)
Maximum power dissipation in no-load condition 11 W
Power loss nominal load max. 51 W

General

Net weight 2 kg
Efficiency > 92 % (600 V DC)
> 90.5 % (400 V AC)
MTBF (IEC 61709, SN 29500)
> 860000 h (40 °C)
Insulation voltage input/output 1.5 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE 4 kV AC (type test)
1.5 kV AC (routine test)
Insulation voltage output / PE 500 V DC (routine test)
Degree of protection IP20
Protection class I
Housing material Steel sheet, zinc-plated
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 10
Stripping length 8 mm
Screw thread M3

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 12
Conductor cross section AWG max. 10
Stripping length 8 mm
Screw thread M3

Connection data for signaling

Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 10
Screw thread M3

Standards

Standard – Safety of transformers EN 61558-2-17
Standard – Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safe isolation DIN VDE 0100-410
Rail applications EN 50121-4

Conformance/approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

Environmental Product Compliance

REACh SVHC Lead 7439-92-1