Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my
QUINT DC/DC converter with maximum functionality
DC/DC converters alter the voltage level, regenerate the voltage at the end of long cables or enable the creation of independent supply systems by means of electrical isolation.
QUINT DC/DC converters magnetically and therefore quickly trip circuit breakers with six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Width | 48 mm |
Height | 130 mm |
Depth | 125 mm |
Installation dimensions | |
Installation distance right/left | 0 mm / 0 mm (≤ 70 °C) |
Installation distance right/left (active) | 15 mm / 15 mm (≤ 70 °C) |
Installation distance top/bottom | 50 mm / 50 mm (≤ 70 °C) |
Installation distance top/bottom (active) | 50 mm / 50 mm (≤ 70 °C) |
Width | 122 mm |
Height | 130 mm |
Depth | 51 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 5 Hz, amplitude ±1.6 mm (according to IEC 60068-2-6) |
5 Hz … 100 Hz, 4g, 90 min. |
Nominal input voltage range | 24 V DC |
Input voltage range | 18 V DC … 32 V DC |
Extended input voltage range in operation | 14 V DC … 18 V DC (Derating) |
Wide-range input | no |
Input voltage range DC | 18 V DC … 32 V DC |
14 V DC … 18 V DC (Consider derating during operation) | |
Voltage type of supply voltage | DC |
Inrush current | < 15 A (typical) |
Inrush current integral (I2t) | < 2.7 A2s |
Mains buffering time | > 12 ms (24 V DC) |
Current consumption | 14 A (24 V, IBOOST) |
Reverse polarity protection | ≤ 30 V DC |
Protective circuit | Transient surge protection; Varistor |
Input fuse | 25 A (internal (device protection)) |
Recommended breaker for input protection | 16 A … 20 A (Characteristics B, C, D, K) |
Efficiency | > 92 % |
Output characteristic | U/I |
Nominal output voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 10 A (-25 °C … 60 °C) |
POWER BOOST (IBoost) | 12.5 A (-25 °C … 40 °C permanent, UOUT = 24 V DC ) |
Selective Fuse Breaking (ISFB) | 60 A (12 ms) |
Magnetic circuit breaker tripping | B2 / B4 / B6 / C2 / C4 |
Derating | 60 °C … 70 °C (2.5%/K) |
Feedback voltage resistance | 35 V DC |
Protection against overvoltage at the output (OVP) | < 35 V DC |
Max. capacitive load | unlimited |
Active current limitation | Approx. 18 A |
Control deviation | < 1 % (change in load, static 10 % … 90 %) |
< 2 % (change in load, dynamic 10 % … 90 %) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 20 mVPP |
Output power | 240 W |
Peak switching voltages nominal load | < 10 mVPP (20 MHz) |
Maximum no-load power dissipation | 1.6 W |
Power loss nominal load max. | 24 W |
Rise time | < 2 ms (UOUT (10 % … 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
2 (Devices) |
Signal: DC OK active
Output description | UOUT > 0.9 x UN: High signal |
Switching voltage range | 18 V DC … 24 V DC |
Maximum inrush current | < 20 mA (short-circuit-proof) |
Signal: POWER BOOST, active
Output description | IOUT < IN: High signal |
Switching voltage range | 18 V DC … 24 V DC |
Maximum inrush current | < 20 mA (short-circuit-proof) |
Signal: UIN OK, active
Output description | UIN > 19.2 V: High signal |
Switching voltage range | 18 V DC … 24 V DC |
Maximum inrush current | ≤ 20 mA (short-circuit-proof) |
Signal: DC OK floating
Output description | Relay |
Output voltage | ≤ 30 V AC/DC |
Maximum inrush current | ≤ 100 mA |
Item number | 2320092 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales Key | CM05 |
Product Key | CMDQ43 |
Catalog Page | Page 248 (C-4-2017) |
GTIN | 4046356481885 |
Weight per Piece (including packing) | 1,162.5 g |
Weight per Piece (excluding packing) | 900 g |
Customs tariff number | 85044083 |
Country of origin | IN |
Connection method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Connection method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Rail applications | EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Safety extra-low voltage | EN 60950-1 (SELV) |
EN 60204 (PELV) | |
Standard – Safe isolation | DIN VDE 0100-410 |
Shipbuilding approval | DNV GL (EMC B) |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
EMC requirements for noise emission | EN 61000-6-3 |
EN 61000-6-4 | |
EMC requirements for noise immunity | EN 61000-6-1 |
EN 61000-6-2 | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 15 kV (Test Level 4) |
Comments | Criterion A |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz … 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1 GHz … 2 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 2 GHz … 3 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | 2 kV (Test Level 3 – asymmetrical) |
Output | 2 kV (Test Level 3 – asymmetrical) |
Signal | 2 kV (Test Level 4 – asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge) | |
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 2 – symmetrical) |
2 kV (Test Level 3 – asymmetrical) | |
Output | 1 kV (Test Level 2 – symmetrical) |
2 kV (Test Level 3 – asymmetrical) | |
Signal | 1 kV (Test Level 2 – asymmetrical) |
Comments | Criterion A |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Emitted interference | |
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Weight | 0.900 kg |
---|---|
Dimensions | 12.50 × 4.8 × 13.00 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)