$ 146.51
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, QUINT DIODE provides the solution: decoupling with diode.
Width | 50 mm |
Height | 130 mm |
Depth | 125 mm |
Horizontal pitch | 2.8 Div. |
Installation dimensions | |
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | -40 °C … 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Maximum altitude | ≤ 5000 m |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz … 150 Hz, 2.3g, 90 min. |
Nominal input voltage range | 12 V DC … 24 V DC |
Input voltage range | 10 V DC … 30 V DC |
Voltage type of supply voltage | DC |
Reverse polarity protection | < yes60 V |
Nominal input current (IN) | 2x 20 A (-25 °C … 60 °C) |
1x 40 A (-25 °C … 60 °C) | |
Maximum current Imax | 2x 30 A (-25°C … 40°C) |
1x 60 A (-25°C … 40°C) | |
Transient surge protection | Varistor |
Voltage drop, input/output | typ. 0.5 V |
Nominal input voltage range | 12 V DC … 24 V DC |
Input voltage range | 10 V DC … 30 V DC |
Input voltage range DC | 10 V DC … 30 V DC |
Efficiency | > 97 % |
> 97 % | |
Output voltage | UIn – |
Nominal output current (IN) | 40 A (Increasing power) |
20 A (Redundancy) | |
Derating | 60 °C … 70 °C (2.5%/K) |
Power loss nominal load max. | 10 W (IOUT = 20 A) |
Connection in series | No |
Derating | 60 °C … 70 °C 2.5 %/K |
Item number | 2320157 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales Key | C15 |
Product Key | CMRQ43 |
Catalog Page | Page 212 (C-6-2015) |
GTIN | 4046356524766 |
Weight per Piece (including packing) | 857.6 g |
Weight per Piece (excluding packing) | 750 g |
Customs tariff number | 85049090 |
Country of origin | CN |
Connection method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 12 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Connection method | Screw connection |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 16 mm² |
Conductor cross section AWG min. | 10 |
Conductor cross section AWG max. | 6 |
Stripping length | 10 mm |
Screw thread | M4 |
Tightening torque, min | 1.2 Nm |
Tightening torque max | 1.5 Nm |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard – Safe isolation | DIN VDE 0100-410 |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
Conformity/Approvals | |
ATEX | II 3 G Ex ec IIC T4 Gc |
DEKRA 20ATEX0041 X | |
IECEx | Ex ec IIC T4 Gc |
IECEx DEK 20.0022X |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
EMC requirements for noise emission | EN 61000-6-3 |
EN 61000-6-4 | |
EMC requirements for noise immunity | EN 61000-6-1 |
EN 61000-6-2 | |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Housing | Level 4 |
Electrostatic discharge | |
Contact discharge | 8 kV (Contact discharge) |
Discharge in air | 15 kV (Air discharge) |
Comments | Criterion A |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz … 1 GHz |
Test field strength | 20 V/m |
Frequency range | 1 GHz … 3 GHz |
Test field strength | 10 V/m |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | 2 kV (level 3 – asymmetrical: conductor to ground) |
Output | 2 kV (level 3 – asymmetrical: conductor to ground) |
Comments | Criterion A |
Surge voltage load (surge) | |
Standards/regulations | EN 61000-4-5 |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
Input/Output | Level 3 |
Frequency range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference | |
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
Weight | 0.8576 kg |
---|---|
Dimensions | 12.5 × 5 × 13 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)