OD5-30T05 Displacement Measurement Sensors – SICK Sensor

USD $ 4,340.38

SKU: SICK 6035977

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6035977
Distance Sensor Model: OD5-30T05
OEM Spec Ref 

Features

System part Sensor head

Mechanics/electronics

Supply voltage Vs DC 12 V … 24 V 1)
Warm-up time ≤ 5 min
Housing material Metal (Aluminum)
Window material Glass
Connection type 0.5 m cable with connector 2)
Indication LEDs, 4” color display on optional evaluation unit
Weight 250 g 3)
Dimensions (W x H x D) 29 mm x 78 mm x 75 mm
Enclosure rating IP67
Protection class III
  • 1) DC 12 V (–5 %) … DC 24 V (+10 %).
  • 2) Can be extended to up to 50 m with extension cable.
  • 3) Includes 0.5 m cable.

Performance

Measuring range 25 mm … 35 mm 1) 2)
Target Natural objects
Repeatability 0.2 µm 3)
Linearity Diffuse ± 8 µm 3)

Specular ± 4 µm 3)

Response time ≥ 0.1 ms 4) 5)
Measuring frequency ≤ 10 kHz 1) 5)
Output time ≥ 0.1 ms
Light source Laser, red
visible red light
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 30 µm x 100 µm (30 mm)
Special task Thickness measurement of transparent material
Additional function Mean-value setting 1 … 4,096x, selectable measuring frequency (automatic / 0.1 ms … 3.2 ms), automatic sensitivity adjustment, manual sensitivity adjustment, Mutual interference, Glass thickness measurement
Thickness measurement of transparent material 0.7 mm … 5 mm
  • 1) 6 % … 90 % remission; at default settings.
  • 2) If there are reflections, the measuring range is reduced to 23.6 mm … 28.6 mm.
  • 3) Measurement at 90% remission (ceramic, white), or mirror for OD5-25x; averaging set to: 256 or 4096 for OD5-25x; constant ambient conditions.
  • 4) Time needed for automatic sensitivity adjustment is calculated as: sampling period x 20. At default setting 100 µs (10kHz) this is <= 2ms.
  • 5) Default setting for OD5-350×100 and OD5-500×200 = 0.8 ms, or 1.25 kHz, all others = 0.1 ms/10 kHz.
  • 6) Wavelength: 658 nm, max. output: 1 mW.

Interfaces

Serial ✔ , RS-422
Remark RS-232 optional via external evaluation unit AOD5
Digital output
Number 1)
Type PNP / NPN
Maximum output current IA ≤ 100 mA
Analog output
Number 1) 2)
Type Current output / voltage output
Current 4 mA … 20 mA, ≤ 300 Ω
Voltage 0 V … 10 V 3)
Laser-off input 1 x laser-off
  • 1) Optional over evaluation unit AOD5.
  • 2) A maximum of three current and three voltage outputs are possible via the AOD5 evaluation unit.
  • 3) Output resistance 100 Ω, min. load 10 k Ω.

Ambient data

Ambient temperature, operation –10 °C … +50 °C
Ambient temperature, storage –20 °C … +60 °C
Relative air humidity (non-condensing) 35 % … 85 %
Temperature drift ± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity Artificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx

Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)