OD1000-6001R15 Displacement measurement sensors – SICK Sensor

USD $ 1,243.00

SKU: SICK 1075638

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1075638
Distance Sensor Model: OD1000-6001R15
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 18 V … 30 V 1)
Ripple ≤ 5 Vpp 2)
Power consumption ≤ 2.5 W 3)
Warm-up time < 10 min
Housing material Metal (zinc diecast)
Window material Plastic (PMMA)
Connection type Cable with male connector, M12, 5-pin, A-coded, 20 cm
Indication OLED display, status LEDs
Control elements 4 buttons
Weight 280 g
Dimensions (W x H x D) 25.9 mm x 71.5 mm x 53.2 mm
Enclosure rating IP65

IP67

Protection class III (EN 50178)
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) May not fall short of or exceed VS tolerances.
  • 3) Without load, at +20 °C.

Performance

Measuring range 200 mm … 1,000 mm 1)
Target Natural objects
Repeatability 0.4 mm 2) 3)
Linearity ± 1.5 mm 2) 4)
Response time ≥ 1.5 ms 5)
Measuring frequency ≤ 3 kHz
Output time ≥ 0.33 ms
Light source Laser, red
visible red light
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 1.5 mm x 1.5 mm (200 mm … 1,000 mm)
Additional function Adjustable average value or media filter, Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB), teach-in of digital output, invertable digital output, teach-in of analog output, Invertable analog output, Switchable analog output (mA / V), Multifunctional input: laser off / external teach-in / deactivated, switch-off display, lock user interface, Display can be rotated by 180°, Alarm function, Edge height jump, Time functions (ON/OFF delay, 1 shot)
  • 1) 6 % … 90 % remission; at default settings.
  • 2) With 90% remission (white), with constant ambient conditions.
  • 3) Statistical error 3 σ.
  • 4) Observe min. warm-up time of 10 minutes.
  • 5) With measuring frequency of 3 kHz, target change white 90%/white 90%.
  • 6) Wavelength 655 nm, max. pulse output 0.78 mW, max. average power 0.39 mW, max. pulse duration 1.8 ms.

Interfaces

IO-Link ✔ , IO-Link V1.1, IO-Link V1.0
Function Process data, parameterization, diagnosis, data storage
Data transmission rate 230,4 kbit/s (COM3) / 38,4 kbit/s (COM2)
Digital input In1
Can be used as laser off, external teach-in, or deactivated
Digital output
Number 1)
Type Push-pull: PNP/NPN
Analog output
Number 1
Type Current output / voltage output
Current 4 mA … 20 mA, ≤ 600 Ω
Voltage 0 V … 10 V, > 20,000 Ω
Resolution 16 bit
  • 1) PNP: HIGH = UV – (< 3 V) / LOW = < 3 V; NPN: HIGH = < 3 V / LOW = UV.

Ambient data

Ambient temperature, operation –10 °C … +50 °C, Operating temperature at VS = 24 V
Ambient temperature, storage –20 °C … +60 °C
Temperature drift 0.15 mm/K
Typ. Ambient light immunity Artificial light: ≤ 3,000 lx 1)

Sunlight: ≤ 10,000 lx

Vibration resistance EN 60068-2-6, EN 60068-2-64
Shock resistance EN 60068-2-27
  • 1) With constant object movement in the measuring range.

Related products