Harmony SCU – Small Touch HMI Controller – Schneider HMI

USD $ 332.20USD $ 539.66

SKU: N/A

Specifications

Main
Part Number HMISCU6A5 HMISCU6B5 HMISCU8B5 HMISCU8A5
Range of product Harmony SCU Harmony SCU Harmony SCU Harmony SCU
Product or component type Small touch HMI controller Small touch HMI controller Small touch HMI controller Small touch HMI controller
Display size 3.5 inch 5.7 inch 3.5 inch 5.7 inch
display type With backlit LED colour TFT LCD With backlit LED colour TFT LCD With backlit LED colour TFT LCD With backlit LED colour TFT LCD
Touch panel Analogue Analogue Analogue Analogue
Device presentation Complete product Complete product Complete product Complete product
Complementary
Display resolution 320 x 240 pixels QVGA 320 x 240 pixels QVGA 320 x 240 pixels QVGA 320 x 240 pixels QVGA
backlight lifespan 50000 hours with 65000 colours 50000 hours with 65000 colours 50000 hours with 65000 colours 50000 hours with 65000 colours
Brightness 16 levels via touch panel 16 levels via touch panel 16 levels via touch panel 16 levels via touch panel
view angle horiz x vert 60° left 60° left 60° left 60° left
60° right 60° right 60° right 60° right
40° top 40° top 40° top 40° top
60° bottom 60° bottom 60° bottom 60° bottom
Character font Chinese (simplified Chinese) Chinese (simplified Chinese) Japanese (ANK, Kanji) Taiwanese (traditional Chinese)
ASCII Japanese (ANK, Kanji) ASCII ASCII
Taiwanese (traditional Chinese) ASCII Taiwanese (traditional Chinese) Korean
Korean Korean Korean Japanese (ANK, Kanji)
Japanese (ANK, Kanji) Taiwanese (traditional Chinese) Chinese (simplified Chinese) Chinese (simplified Chinese)
Supply External source External source External source External source
[Us] rated supply voltage 24 V (20.4…28.8 V)DC 24 V (20.4…28.8 V)DC 24 V (20.4…28.8 V)DC 24 V (20.4…28.8 V)DC
Immunity to microbreaks 10 ms 10 ms 10 ms 10 ms
Inrush current 30 A 30 A 30 A 30 A
Power consumption in W 15 W 24 W 15 W 24 W
Local signalling No indicator No indicator No indicator No indicator
Number of pages Limited by internal memory capacity Limited by internal memory capacity Limited by internal memory capacity Limited by internal memory capacity
Software designation SoMachine SoMachine SoMachine SoMachine
Operating system Harmony Harmony Harmony Harmony
Processor name CPU RISC CPU RISC CPU RISC CPU RISC
Processor frequency 333 MHz 333 MHz 333 MHz 333 MHz
memory description Flash NAND, 128 MB Flash NAND, 128 MB Flash NAND, 128 MB Flash NAND, 128 MB
Internal data storage FRAM, 128 kB Internal data storage FRAM, 128 kB Internal data storage FRAM, 128 kB Internal data storage FRAM, 128 kB
Application run DRAM, 128 MB Application run DRAM, 128 MB Application run DRAM, 128 MB Application run DRAM, 128 MB
integrated connection type 1 serial link – RJ45 – RS232/RS485 (rate: <= 115.2 kbits/s) 1 serial link – RJ45 – RS232/RS485 (rate: <= 115.2 kbits/s) 1 serial link – RJ45 – RS232/RS485 (rate: <= 115.2 kbits/s) 1 serial link – RJ45 – RS232/RS485 (rate: <= 115.2 kbits/s)
1 Ethernet TCP/IP – RJ45 1 Ethernet TCP/IP – RJ45 1 Ethernet TCP/IP – RJ45 1 Ethernet TCP/IP – RJ45
1 USB 2.0 type mini B 1 USB 2.0 type mini B 1 USB 2.0 type mini B 1 USB 2.0 type mini B
1 USB 2.0 type A 1 USB 2.0 type A 1 USB 2.0 type A 1 USB 2.0 type A
CANopen master bus – SUB-D 9 CANopen master bus – SUB-D 9 CANopen master bus – SUB-D 9 CANopen master bus – SUB-D 9
Realtime clock Built-in Built-in Built-in Built-in
Downloadable protocols Modbus TCP/IP Modbus CANopen Modbus TCP/IP
CANopen Modbus TCP/IP Modbus TCP/IP CANopen
Modbus CANopen Modbus Modbus
fixing mode By 1 nut – diameter: Ø 22 mm, mounting on: 1…6 mm thick panel By 1 nut – diameter: Ø 22 mm, mounting on: 1…6 mm thick panel By 1 nut – diameter: Ø 22 mm, mounting on: 1…6 mm thick panel By 1 nut – diameter: Ø 22 mm, mounting on: 1…6 mm thick panel
Enclosure material PC/PBT PC/PBT and PAA PC/PBT PC/PBT and PAA
shock resistance 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27
294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27
vibration resistance +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6 +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6 +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6 +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6
1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6 1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6 1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6 1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6
electromagnetic compatibility Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay wires) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (COM line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (COM line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (COM line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (COM line) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (CAN line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (CAN line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (CAN line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (CAN line) conforming to IEC 61000-4-4
Surge immunity test – test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5
Surge immunity test – test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5
Surge immunity test – test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5
Surge immunity test – test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test – test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to IEC 61000-4-6
Conducted emission – test level: 150 kHz…30 MHz conforming to EN 55011 Conducted emission – test level: 150 kHz…30 MHz conforming to EN 55011 Conducted emission – test level: 150 kHz…30 MHz conforming to EN 55011 Conducted emission – test level: 150 kHz…30 MHz conforming to EN 55011
Radiated emission – test level: 30 MHz…1 GHz conforming to EN 55011 Radiated emission – test level: 30 MHz…1 GHz conforming to EN 55011 Radiated emission – test level: 30 MHz…1 GHz conforming to EN 55011 Radiated emission – test level: 30 MHz…1 GHz conforming to EN 55011
discrete input number 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1
6 for digital input conforming to IEC 61131-2 Type 1 6 for digital input conforming to IEC 61131-2 Type 1 14 for digital input conforming to IEC 61131-2 Type 1 14 for digital input conforming to IEC 61131-2 Type 1
discrete input voltage 24 V DC, discrete input logic: sink or source (positive/negative) 24 V DC, discrete input logic: sink or source (positive/negative) 24 V DC, discrete input logic: sink or source (positive/negative) 24 V DC, discrete input logic: sink or source (positive/negative)
number of common point 1 for fast input (HSC mode) 1 for fast input (HSC mode) 1 for fast input (HSC mode) 1 for fast input (HSC mode)
1 for digital input 1 for digital input 2 for digital input 2 for digital input
discrete input current 7.83 mA for fast input 7.83 mA for fast input 7.83 mA for fast input 7.83 mA for fast input
5 mA for digital 5 mA for digital 5 mA for digital 5 mA for digital
Input impedance 2.81 kOhm 4.7 kOhm 2.81 kOhm 2.81 kOhm
4.7 kOhm 2.81 kOhm 4.7 kOhm 4.7 kOhm
sensor power supply 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA
15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA 15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA 15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA 15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA
configurable filtering time 0 ms no filter (none) 0 ms no filter (none) 0 ms no filter (none) 0 ms no filter (none)
0.004…0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 0.004…0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 0.004…0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 0.004…0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2))
3…12 ms integrator (none/run/stop) 3…12 ms integrator (none/run/stop) 3…12 ms integrator (none/run/stop) 3…12 ms integrator (none/run/stop)
maximum input frequency 100 kHz for fast input (encoder mode) – control type A/B 100 kHz for fast input (encoder mode) – control type A/B 100 kHz for fast input (encoder mode) – control type A/B 100 kHz for fast input (encoder mode) – control type A/B
100 kHz for fast input – control type single phase 100 kHz for fast input – control type single phase 100 kHz for fast input – control type single phase 100 kHz for fast input – control type single phase
100 kHz for fast input – control type pulse/direction 100 kHz for fast input – control type pulse/direction 100 kHz for fast input – control type pulse/direction 100 kHz for fast input – control type pulse/direction
maximum cable distance between devices Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input
Shielded cable: <100 m for digital input Shielded cable: <100 m for digital input Shielded cable: <100 m for digital input Shielded cable: <100 m for digital input
Unshielded cable: <50 m for digital input Unshielded cable: <50 m for digital input Unshielded cable: <50 m for digital input Unshielded cable: <50 m for digital input
Connection pitch 3.5 mm 3.5 mm 3.5 mm 3.5 mm
overvoltage protection With overvoltage protection With overvoltage protection With overvoltage protection With overvoltage protection
isolation between channels and internal logic 500 V DC 500 V DC 500 V DC 500 V DC
Isolation between channels None None None None
discrete output number 2 fast output (normal mode), output logic: source 2 fast output (normal mode), output logic: source 2 fast output (normal mode), output logic: source 2 fast output (normal mode), output logic: source
6 digital output, output logic: source 6 digital output, output logic: source 8 digital output, output logic: source 8 digital output, output logic: source
discrete output voltage 24 V DC (voltage limit: 19.2…28.8 V) with transistor discrete output(s) 24 V DC (voltage limit: 19.2…28.8 V) with transistor discrete output(s) 24 V DC (voltage limit: 19.2…28.8 V) with transistor discrete output(s) 24 V DC (voltage limit: 19.2…28.8 V) with transistor discrete output(s)
24 V DC (voltage limit: 5…30 V) with relay discrete output(s) 24 V DC (voltage limit: 5…30 V) with relay discrete output(s) 24 V DC (voltage limit: 5…30 V) with relay discrete output(s) 24 V DC (voltage limit: 5…30 V) with relay discrete output(s)
220 V AC (voltage limit: 100…250 V) with relay discrete output(s) 220 V AC (voltage limit: 100…250 V) with relay discrete output(s) 220 V AC (voltage limit: 100…250 V) with relay discrete output(s) 220 V AC (voltage limit: 100…250 V) with relay discrete output(s)
input/output number 2 for fast input, terminal(s): FI0…FI1 2 for fast input, terminal(s): FI0…FI1 2 for fast input, terminal(s): FI0…FI1 2 for fast input, terminal(s): FI0…FI1
2 for fast output, terminal(s): FQ0…FQ1 2 for fast output, terminal(s): FQ0…FQ1 14 for digital input, terminal(s): DI0…DI13 14 for digital input, terminal(s): DI0…DI13
6 for digital input, terminal(s): DI0…DI5 6 for digital input, terminal(s): DI0…DI5 2 for fast output, terminal(s): FQ0…FQ1 2 for fast output, terminal(s): FQ0…FQ1
6 for digital output, terminal(s): DQ0…DQ5 6 for digital output, terminal(s): DQ0…DQ5 8 for digital output, terminal(s): DQ0…DQ7 8 for digital output, terminal(s): DQ0…DQ7
discrete output current 2 A 4 A), response time 5 ms with opening contact for digital output 2 A 4 A), response time 5 ms with opening contact for digital output 2 A 4 A), response time 5 ms with opening contact for digital output 2 A 4 A), response time 5 ms with opening contact for digital output
2 A 4 A), response time 2 ms with closing contact for digital output 2 A 4 A), response time 2 ms with closing contact for digital output 2 A 4 A), response time 2 ms with closing contact for digital output 2 A 4 A), response time 2 ms with closing contact for digital output
300 mA, response time 2 ms for fast output (normal mode) 300 mA, response time 2 ms for fast output (normal mode) 300 mA, response time 2 ms for fast output (normal mode) 300 mA, response time 2 ms for fast output (normal mode)
50 mA, response time 2 ms for fast output (PWM or PTO mode) 50 mA, response time 2 ms for fast output (PWM or PTO mode) 50 mA, response time 2 ms for fast output (PWM or PTO mode) 50 mA, response time 2 ms for fast output (PWM or PTO mode)
insulation resistance > 10 MOhm between the I/O and internal logic > 10 MOhm between the I/O and internal logic > 10 MOhm between the I/O and internal logic > 10 MOhm between the I/O and internal logic
> 10 MOhm between power supply and earth > 10 MOhm between power supply and earth > 10 MOhm between power supply and earth > 10 MOhm between power supply and earth
maximum output frequency 100 kHz for fast output (PTO mode) 100 kHz for fast output (PTO mode) 100 kHz for fast output (PTO mode) 100 kHz for fast output (PTO mode)
1 kHz for fast output (PWM mode) 1 kHz for fast output (PWM mode) 1 kHz for fast output (PWM mode) 1 kHz for fast output (PWM mode)
absolute accuracy error +/- 0.1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) +/- 0.1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) +/- 0.1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) +/- 0.1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode)
1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) 1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) 1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode) 1 % of full scale cyclic ratio 1…99% for fast output (PWM or PTO mode)
+/- 5 % of full scale cyclic ratio 10…90% for fast output (PWM or PTO mode) +/- 5 % of full scale cyclic ratio 10…90% for fast output (PWM or PTO mode) +/- 5 % of full scale cyclic ratio 10…90% for fast output (PWM or PTO mode) +/- 5 % of full scale cyclic ratio 10…90% for fast output (PWM or PTO mode)
+/- 10 % of full scale cyclic ratio 20…80% for fast output (PWM or PTO mode) +/- 10 % of full scale cyclic ratio 20…80% for fast output (PWM or PTO mode) +/- 10 % of full scale cyclic ratio 20…80% for fast output (PWM or PTO mode) +/- 10 % of full scale cyclic ratio 20…80% for fast output (PWM or PTO mode)
+/- 15 % of full scale cyclic ratio 30…70% for fast output (PWM or PTO mode) +/- 15 % of full scale cyclic ratio 30…70% for fast output (PWM or PTO mode) +/- 15 % of full scale cyclic ratio 30…70% for fast output (PWM or PTO mode) +/- 15 % of full scale cyclic ratio 30…70% for fast output (PWM or PTO mode)
analogue input number 2 for analog input 2 for analog input
2 for RTDs 2 for RTDs
analogue input range 0…20 mA/4…20 mA – resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %) 0…20 mA/4…20 mA – resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %)
-10…+10 V or 0…10 V – resolution: 12 bits + sign, input impedance: >= 1 MOhm -10…+10 V or 0…10 V – resolution: 12 bits + sign, input impedance: >= 1 MOhm
analogue input type RTD at – 200…600 °C – resolution: 16 bits temperature probe: Pt 100/Pt 1000 RTD at – 200…600 °C – resolution: 16 bits temperature probe: Pt 100/Pt 1000
RTD at – 50…200 °C – resolution: 16 bits temperature probe: Ni 100/Ni 1000 RTD at – 50…200 °C – resolution: 16 bits temperature probe: Ni 100/Ni 1000
RTD at – 200…760 °C – resolution: 16 bits (thermocouple J) RTD at – 200…760 °C – resolution: 16 bits (thermocouple J)
RTD at – 240…1370 °C – resolution: 16 bits (thermocouple K) RTD at – 240…1370 °C – resolution: 16 bits (thermocouple K)
RTD at 0…1600 °C – resolution: 16 bits (thermocouple R) RTD at 0…1600 °C – resolution: 16 bits (thermocouple R)
RTD at 200…1800 °C – resolution: 16 bits (thermocouple B) RTD at 200…1800 °C – resolution: 16 bits (thermocouple B)
RTD at 0…1600 °C – resolution: 16 bits (thermocouple S) RTD at 0…1600 °C – resolution: 16 bits (thermocouple S)
RTD at – 200…400 °C – resolution: 16 bits (thermocouple T) RTD at – 200…400 °C – resolution: 16 bits (thermocouple T)
RTD at – 200…900 °C – resolution: 16 bits (thermocouple E) RTD at – 200…900 °C – resolution: 16 bits (thermocouple E)
RTD at – 200…1300 °C – resolution: 16 bits (thermocouple N) RTD at – 200…1300 °C – resolution: 16 bits (thermocouple N)
analogue output number 2 resistive load for 12 bits + sign 2 resistive load for 12 bits + sign
analogue output range 0…20 mA/4…20 mA (> 300 Ohm) for open-circuit 0…20 mA/4…20 mA (> 300 Ohm) for open-circuit
-10…10 V/0…10 V (> 2 kOhm) for short-circuit -10…10 V/0…10 V (> 2 kOhm) for short-circuit
Height 74.95 mm 129.4 mm 74.95 mm 129.4 mm
Width 128 mm 163 mm 128 mm 163 mm
Depth 102 mm 76.22 mm 102 mm 76.22 mm
Net weight 0.551 kg 0.803 kg 0.512 kg 0.764 kg
Environment
Standards CSA C22.2 No 213 Class I Division 2 FCC Class A IEC 61000-6-2 IEC 61000-6-2
EN 61131-2 EN 61131-2 FCC Class A ANSI/ISA 12-12-01
IEC 61000-6-2 UL 508 UL 508 CSA C22.2 No 213 Class I Division 2
ANSI/ISA 12-12-01 IEC 61000-6-2 EN 61131-2 FCC Class A
UL 508 CSA C22.2 No 213 Class I Division 2 CSA C22.2 No 213 Class I Division 2 EN 61131-2
FCC Class A ANSI/ISA 12-12-01 ANSI/ISA 12-12-01 UL 508
Product certifications CULus CSA 22-2 No 142 CULus 508 CULus 508 CULus 508
cUL 1604 Class 1 Division 2 cULus CSA 22-2 No 142 cUL 1604 Class 1 Division 2 KCC
C-Tick GOST KCC cULus CSA 22-2 No 142
GOST cUL 1604 Class 1 Division 2 C-Tick GOST
KCC C-Tick cULus CSA 22-2 No 142 cUL 1604 Class 1 Division 2
cULus 508 KCC GOST C-Tick
UKCA
UKEX
Marking CE CE CE CE
Ambient air temperature for operation 0…50 °C 0…50 °C 0…50 °C 0…50 °C
Ambient air temperature for storage -20…60 °C -20…60 °C -20…60 °C -20…60 °C
relative humidity 5…85 % without condensation 5…85 % without condensation 5…85 % without condensation 5…85 % without condensation
Operating altitude <= 2000 m <= 2000 m <= 2000 m <= 2000 m
Storage altitude 0…10000 m 0…10000 m 0…10000 m 0…10000 m
Maximum pressure 800…1114 hPa 800…1114 hPa 800…1114 hPa 800…1114 hPa
IP degree of protection IP20 (rear panel) conforming to IEC 60529 IP20 (rear panel) conforming to IEC 60529 IP20 (rear panel) conforming to IEC 60529 IP20 (rear panel) conforming to IEC 60529
IP65 (front panel) conforming to IEC 60529 IP65 (front panel) conforming to IEC 60529 IP65 (front panel) conforming to IEC 60529 IP65 (front panel) conforming to IEC 60529
NEMA degree of protection NEMA 4X front panel NEMA 4X front panel NEMA 4X front panel NEMA 4X front panel
pollution degree 2 conforming to IEC 60664 2 conforming to IEC 60664 2 conforming to IEC 60664 2 conforming to IEC 60664
environmental characteristic Corrosive gas free Corrosive gas free Corrosive gas free Corrosive gas free
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 18.4 cm 18.8 cm 18.4 cm 11.000 cm
Package 1 Width 10.8 cm 11 cm 10.8 cm 19.000 cm
Package 1 Length 26.7 cm 20.7 cm 26.7 cm 26.700 cm
Package 1 Weight 1.113 kg 1.364 kg 1083 g 1.391 kg
Unit Type of Package 2 S03 S03 S03 S03
Number of Units in Package 2 4 4 4 4
Package 2 Height 30 cm 30 cm 30 cm 30.000 cm
Package 2 Width 30 cm 30 cm 30 cm 30.000 cm
Package 2 Length 40 cm 40 cm 40 cm 40.000 cm
Package 2 Weight 6.044 kg
Unit Type of Package 3 P12
Number of Units in Package 3 64
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 109.040 kg

 

Weight N/A