USD $ 14.95 – USD $ 26.68
class | Detection distance (Note 1) |
Model | Supply voltage | output | Output actions | |
---|---|---|---|---|---|---|
Maximum working distance |
Stabilize detection range |
|||||
Single distance masking |
1.5mm±10% | 0~1.2mm | GX-108MA | 12~24V DC ±10% |
NPN open collector transistor |
Approaching ON |
GX-108MB | ON when leaving | |||||
2mm±10% | 0~1.6mm | GX-112MA | Approaching ON | |||
GX-112MB | ON when leaving | |||||
5mm±10% | 0~4mm | GX-118MA | Approaching ON | |||
GX-118MB | ON when leaving | |||||
10mm±10% | 0~8mm | GX-130MA | Approaching ON | |||
GX-130MB | ON when leaving | |||||
Single distance unmasked |
2mm±10% | 0~1.6mm | GX-108MLA | Approaching ON | ||
GX-108MLB | ON when leaving | |||||
4mm±10% | 0~3.2mm | GX-112MLA | Approaching ON | |||
GX-112MLB | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-118MLA | Approaching ON | |||
GX-118MLB | ON when leaving | |||||
15mm±10% | 0~12mm | GX-130MLA | Approaching ON | |||
GX-130MLB | ON when leaving | |||||
Single distance masking |
1.5mm±10% | 0~1.2mm | GX-108MA-P | 12~24V DC ±10% |
PNP open collector transistor |
Approaching ON |
GX-108MB-P | ON when leaving | |||||
2mm±10% | 0~1.6mm | GX-112MA-P | Approaching ON | |||
GX-112MB-P | ON when leaving | |||||
5mm±10% | 0~4mm | GX-118MA-P | Approaching ON | |||
GX-118MB-P | ON when leaving | |||||
10mm±10% | 0~8mm | GX-130MA-P | Approaching ON | |||
GX-130MB-P | ON when leaving | |||||
Single distance unmasked |
2mm±10% | 0~1.6mm | GX-108MLA-P | Approaching ON | ||
GX-108MLB-P | ON when leaving | |||||
4mm±10% | 0~3.2mm | GX-112MLA-P | Approaching ON | |||
GX-112MLB-P | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-118MLA-P | Approaching ON | |||
GX-118MLB-P | ON when leaving | |||||
15mm±10% | 0~12mm | GX-130MLA-P | Approaching ON | |||
GX-130MLB-P | ON when leaving | |||||
(Note 1): | The maximum working distance is the maximum distance at which the sensor can detect an object detected by the standard. The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage). |
class | Detection distance (Note 1) |
Model | Supply voltage | output | Output actions | |
---|---|---|---|---|---|---|
Maximum working distance |
Stabilize detection range |
|||||
2x distance shielding |
2mm±10% | 0~1.6mm | GX-108MKA | 12~24V DC ±10% |
NPN open collector transistor | Approaching ON |
GX-108MKB | ON when leaving | |||||
4mm±10% | 0~3.2mm | GX-112MKA | Approaching ON | |||
GX-112MKB | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-118MKA | Approaching ON | |||
GX-118MKB | ON when leaving | |||||
15mm±10% | 0~12mm | GX-130MKA | Approaching ON | |||
GX-130MKB | ON when leaving | |||||
2x distance unmasked |
4mm±10% | 0~3.2mm | GX-108MLKA | Approaching ON | ||
GX-108MLKB | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-112MLKA | Approaching ON | |||
GX-112MLKB | ON when leaving | |||||
16mm±10% | 0~12.8mm | GX-118MLKA | Approaching ON | |||
GX-118MLKB | ON when leaving | |||||
30mm±10% | 0~24mm | GX-130MLKA | Approaching ON | |||
GX-130MLKB | ON when leaving | |||||
2x distance shielding |
2mm±10% | 0~1.6mm | GX-108MKA-P | PNP open collector transistor | Approaching ON | |
GX-108MKB-P | ON when leaving | |||||
4mm±10% | 0~3.2mm | GX-112MKA-P | Approaching ON | |||
GX-112MKB-P | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-118MKA-P | Approaching ON | |||
GX-118MKB-P | ON when leaving | |||||
15mm±10% | 0~12mm | GX-130MKA-P | Approaching ON | |||
GX-130MKB-P | ON when leaving | |||||
2x distance unmasked |
4mm±10% | 0~3.2mm | GX-108MLKA-P | Approaching ON | ||
GX-108MLKB-P | ON when leaving | |||||
8mm±10% | 0~6.4mm | GX-112MLKA-P | Approaching ON | |||
GX-112MLKB-P | ON when leaving | |||||
16mm±10% | 0~12.8mm | GX-118MLKA-P | Approaching ON | |||
GX-118MLKB-P | ON when leaving | |||||
30mm±10% | 0~24mm | GX-130MLKA-P | Approaching ON | |||
GX-130MLKB-P | ON when leaving | |||||
(Note 1): | The maximum working distance is the maximum distance at which the sensor can detect an object detected by the standard. The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage). |
type | Single distance shielding type | ||||
---|---|---|---|---|---|
Model | Approaching ON | GX-108MA | GX-112MA | GX-118MA | GX-130MA |
GX-108MA-P | GX-112MA-P | GX-118MA-P | GX-130MA-P | ||
ON when leaving | GX-108MB | GX-112MB | GX-118MB | GX-130MB | |
GX-108MB-P | GX-112MB-P | GX-118MB-P | GX-130MB-P | ||
Maximum working distance (Note 2) | 1.5mm±10% | 2mm±10% | 5mm±10% | 10mm±10% | |
Stable detection range (Note 2) | 0mm~1.2mm | 0mm~1.6mm | 0mm~4mm | 0mm~8mm | |
Standard detection objects | Iron plate 8mm×8mm×t1mm | Iron plate 12mm×12mm×t1mm | Iron plate 18mm× 18mm×t1mm | Iron plate 30mm×30mm×t1mm | |
Directives to which the CE marking applies | EMC directive, RoHS directive | ||||
Should be poor | Less than 20% of working distance (using standard detection objects) | ||||
Repeatability | Less than 5% of the working distance | ||||
Supply voltage | 12V~24V DC±10%, pulsating P-P 10% or less | ||||
Consumes current | 15mA or less | 20mA or less | |||
output | < NPN output > NPN open collector transistor • Maximum current inflow: 100mA (GX-108□) 200mA (except GX-108□)• Extended voltage: 30V DC or less• Residual voltage: 2.0V or less < PNP output > PNP open collector transistor • Maximum source current: 100mA (GX-108□) 200mA (except GX-108□)• Applied voltage: 30V DC or less• Residual voltage: 2.0V or less |
||||
Maximum reaction frequency | 2kHz | 1.5kHz | 1kHz | 0.5kHz | |
Working status indicator | Orange LED (on when output ON) | ||||
Environmental performance |
Protection Construct | IP67(IEC) | |||
Use ambient temperature | Use temperature -25 °C ~ +70 °C, storage: -40 °C ~ +80 °C | ||||
Use ambient humidity | 85%RH or less (when operating at +70°C) | ||||
Withstand voltage | Connect an AC voltage of 1000V between all connected power terminals and the housing for 1 minute | ||||
Insulation resistance | Between all power connection terminals and housing, above 500MΩ, based on a DC500V high-impedance meter | ||||
Vibration resistant | In the X, Y and Z directions, it can withstand the vibration of 10Hz~50Hz and double amplitude of 1.5mm for up to 2 hours | ||||
Impact resistant | In the X, Y and Z directions, it can withstand three impacts with an acceleration of 500m/s2 (about 50G). | ||||
Material | Shell: nickel-plated brass (stainless steel except GX-108 housing), front plug: PBT, rear plug: PC | ||||
cable | A 3-core rubber cable with a cross-sectional area of 0.2mm2 (except for GX-108, which has a cross-sectional area of 0.1mm2) and a length of 2m | ||||
Cable extension | The total length of cables with a cross-sectional area of 0.3mm2 or more can be extended to 100m | ||||
Weight (Note 3) | Approx. 45g | Approx. 95g | Approx. 115g | Approx. 175g |
(Note 1) The measurement condition is ambient temperature = +23°C if not specified.
(Note 2) The maximum working distance is the maximum distance at which the sensor can detect a standard detection object.
The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage).
(Note 3) This weight includes the weight of two nuts.
type | Single distance unshielded type | ||||
---|---|---|---|---|---|
Model | Approaching ON | GX-108MLA | GX-112MLA | GX-118MLA | GX-130MLA |
GX-108MLA-P | GX-112MLA-P | GX-118MLA-P | GX-130MLA-P | ||
ON when leaving | GX-108MLB | GX-112MLB | GX-118MLB | GX-130MLB | |
GX-108MLB-P | GX-112MLB-P | GX-118MLB-P | GX-130MLB-P | ||
Maximum working distance (Note 2) | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | |
Stable detection range (Note 2) | 0mm~1.6mm | 0mm~3.2mm | 0mm~6.4mm | 0mm~12mm | |
Standard detection objects | Iron plate 8mm×8mm×t1mm | Iron plate 12mm×12mm×t1mm | Iron plate 24mm×24mm×t1mm | Iron plate 45mm×45mm×t1mm | |
Directives to which the CE marking applies | EMC directive, RoHS directive | ||||
Should be poor | Less than 20% of working distance (using standard detection objects) | ||||
Repeatability | Less than 5% of the working distance | ||||
Supply voltage | 12V~24V DC±10%, pulsating P-P 10% or less | ||||
Consumes current | 10mA or less | 15mA or less | 20mA or less | ||
output | < NPN output > NPN open collector transistor • Maximum current inflow: 100mA (GX-108□) 200mA (except GX-108□)• Extended voltage: 30V DC or less• Residual voltage: 2.0V or less < PNP output > PNP open collector transistor • Maximum source current: 100mA (GX-108□) 200mA (except GX-108□)• Applied voltage: 30V DC or less• Residual voltage: 2.0V or less |
||||
Maximum reaction frequency | 1kHz | 0.8kHz | 0.4kHz | 0.1kHz | |
Working status indicator | Orange LED (on when output ON) | ||||
Environmental performance |
Protection Construct | IP67(IEC) | |||
Use ambient temperature | Use temperature -25 °C ~ +70 °C, storage: -40 °C ~ +80 °C | ||||
Use ambient humidity | 85%RH or less (when operating at +70°C) | ||||
Withstand voltage | Connect an AC voltage of 1000V between all connected power terminals and the housing for 1 minute | ||||
Insulation resistance | Between all power connection terminals and housing, above 500MΩ, based on a DC500V high-impedance meter | ||||
Vibration resistant | In the X, Y and Z directions, it can withstand the vibration of 10Hz~50Hz and double amplitude of 1.5mm for up to 2 hours | ||||
Impact resistant | In the X, Y and Z directions, it can withstand three impacts with an acceleration of 500m/s2 (about 50G). | ||||
Material | Shell: nickel-plated brass (stainless steel except GX-108), front plug: PBT, back plug: PC | ||||
cable | A 3-core rubber cable with a cross-sectional area of 0.2mm2 (except for GX-108, which has a cross-sectional area of 0.1mm2) and a length of 2m | ||||
Cable extension | The total length of cables with a cross-sectional area of 0.3mm2 or more can be extended to 100m | ||||
Weight (Note 3) | Approx. 45g | Approx. 95g | Approx. 110g | Approx. 180g |
(Note 1) The measurement condition is ambient temperature = +23°C if not specified.
(Note 2) The maximum working distance is the maximum distance at which the sensor can detect a standard detection object.
The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage).
(Note 3) This weight includes the weight of two nuts.
type | 2x distance shielding type | ||||
---|---|---|---|---|---|
Model | Approaching ON | GX-108MKA | GX-112MKA | GX-118MKA | GX-130MKA |
GX-108MKA-P | GX-112MKA-P | GX-118MKA-P | GX-130MKA-P | ||
ON when leaving | GX-108MKB | GX-112MKB | GX-118MKB | GX-130MKB | |
GX-108MKB-P | GX-112MKB-P | GX-118MKB-P | GX-130MKB-P | ||
Maximum working distance (Note 2) | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | |
Stable detection range (Note 2) | 0mm~1.6mm | 0mm~3.2mm | 0mm~6.4mm | 0mm~12mm | |
Standard detection objects | Iron plate 8mm×8mm×t1mm | Iron plate 12mm×12mm×t1mm | Iron plate 24mm×24mm×t1mm | Iron plate 45mm×45mm×t1mm | |
Directives to which the CE marking applies | EMC directive, RoHS directive | ||||
Should be poor | Less than 20% of working distance (using standard detection objects) | ||||
Repeatability | Less than 5% of the working distance | ||||
Supply voltage | 12V~24V DC±10%, pulsating P-P 10% or less | ||||
Consumes current | 10mA or less | 15mA or less | 22mA or less | ||
output | < NPN output > NPN open collector transistor • Maximum current inflow: 100mA (GX-108□) 200mA (except GX-108□)• Extended voltage: 30V DC or less• Residual voltage: 2.0V or less < PNP output > PNP open collector transistor • Maximum source current: 100mA (GX-108□) 200mA (except GX-108□)• Applied voltage: 30V DC or less• Residual voltage: 2.0V or less |
||||
Maximum reaction frequency | 1.5kHz | 1kHz | 0.5kHz | 0.25kHz | |
Working status indicator | Orange LED (on when output ON) | ||||
Environmental performance |
Protection Construct | IP67(IEC) | |||
Use ambient temperature | Use temperature -25 °C ~ +70 °C, storage: -40 °C ~ +80 °C | ||||
Use ambient humidity | 85%RH or less (when operating at +70°C) | ||||
Withstand voltage | Connect an AC voltage of 1000V between all connected power terminals and the housing for 1 minute | ||||
Insulation resistance | Between all power connection terminals and housing, above 500MΩ, based on a DC500V high-impedance meter | ||||
Vibration resistant | In the X, Y and Z directions, it can withstand the vibration of 10Hz~50Hz and double amplitude of 1.5mm for up to 2 hours | ||||
Impact resistant | In the X, Y and Z directions, it can withstand three impacts with an acceleration of 500m/s2 (about 50G). | ||||
Material | Shell: nickel-plated brass (stainless steel except GX-108 housing), front plug: PBT, rear plug: PC | ||||
cable | A 3-core rubber cable with a cross-sectional area of 0.2mm2 (except for GX-108, which has a cross-sectional area of 0.1mm2) and a length of 2m | ||||
Cable extension | The total length of cables with a cross-sectional area of 0.3mm2 or more can be extended to 100m | ||||
Weight (Note 3) | Approx. 45g | Approx. 95g | Approx. 115g | Approx. 175g |
(Note 1) The measurement condition when not specified is that the ambient temperature = +23°C.
(Note 2) The maximum working distance is the maximum distance at which the sensor can detect a standard detection object.
The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage).
(Note 3) This weight includes the weight of two nuts.
type | 2 times the distance unshielded type | ||||
---|---|---|---|---|---|
Model | Approaching ON | GX-108MLKA | GX-112MLKA | GX-118MLKA | GX-130MLKA |
GX-108MLKA-P | GX-112MLKA-P | GX-118MLKA-P | GX-130MLKA-P | ||
ON when leaving | GX-108MLKB | GX-112MLKB | GX-118MLKB | GX-130MLKB | |
GX-108MLKB-P | GX-112MLKB-P | GX-118MLKB-P | GX-130MLKB-P | ||
Maximum working distance (Note 2) | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% | |
Stable detection range (Note 2) | 0mm~3.2mm | 0mm~6.4mm | 0mm~12.8mm | 0mm~24mm | |
Standard detection objects | Iron plate 12mm×12mm×t1mm | Iron plate 24mm×24mm×t1mm | Iron plate 48mm×48mm×t1mm | Iron plate 90mm×90mm×t1mm | |
Directives to which the CE marking applies | EMC directive, RoHS directive | ||||
Should be poor | Less than 20% of working distance (using standard detection objects) | ||||
Repeatability | Less than 5% of the working distance | ||||
Supply voltage | 12V~24V DC±10%, pulsating P-P 10% or less | ||||
Consumes current | 10mA or less | 15mA or less | 22mA or less | ||
output | < NPN output > NPN open collector transistor • Maximum current inflow: 100mA (GX-108□) 200mA (except GX-108□)• Extended voltage: 30V DC or less• Residual voltage: 2.0V or less < PNP output > PNP open collector transistor • Maximum source current: 100mA (GX-108□) 200mA (except GX-108□)• Applied voltage: 30V DC or less• Residual voltage: 2.0V or less |
||||
Maximum reaction frequency | 1kHz | 0.8kHz | 0.4kHz | 0.1kHz | |
Working status indicator | Orange LED (on when output ON) | ||||
Environmental performance |
Protection Construct | IP67(IEC) | |||
Use ambient temperature | Use temperature -25 °C ~ +70 °C, storage: -40 °C ~ +80 °C | ||||
Use ambient humidity | 85%RH or less (when operating at +70°C) | ||||
Withstand voltage | Connect an AC voltage of 1000V between all connected power terminals and the housing for 1 minute | ||||
Insulation resistance | Between all power connection terminals and housing, above 500MΩ, based on a DC500V high-impedance meter | ||||
Vibration resistant | In the X, Y and Z directions, it can withstand the vibration of 10Hz~50Hz and double amplitude of 1.5mm for up to 2 hours | ||||
Impact resistant | In the X, Y and Z directions, it can withstand three impacts with an acceleration of 500m/s2 (about 50G). | ||||
Material | Shell: nickel-plated brass (stainless steel except GX-108), front plug: PBT, back plug: PC | ||||
cable | A 3-core rubber cable with a cross-sectional area of 0.2mm2 (except for GX-108, which has a cross-sectional area of 0.1mm2) and a length of 2m | ||||
Cable extension | The total length of cables with a cross-sectional area of 0.3mm2 or more can be extended to 100m | ||||
Weight (Note 3) | Approx. 45g | Approx. 90g | Approx. 110g | Approx. 180g |
(Note 1) The measurement condition when not specified is that the ambient temperature = +23°C.
(Note 2) The maximum working distance is the maximum distance at which the sensor can detect a standard detection object.
The stable detection range is the detection distance at which the sensor stabilizes the detected object of the standard (even in the case of ambient temperature changes and/or fluctuations in the supply voltage).
(Note 3) This weight includes the weight of two nuts.
Weight | N/A |
---|---|
Model | GX-108MA, GX-108MA-P, GX-108MLA, GX-112MA, GX-112MLA, GX-112MA-P, GX-112MLA-P, GX-130MLA, GX-130MA, GX-112MLKA, GX-112MB |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)
inosaki.com 2008 -2024