Contact Us:
sales@inosaki.com

F3SJ-B[][][][]N25 – Omron Safety Light Curtains

USD $ 396.29USD $ 1,234.64

SKU N/A Category

F3SJ-B

Main Units

Safety Light Curtain

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Application Detection
capability
Beam gap Operating
range
Protective height
(mm)
Model
PNP output NPN output
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 2,065 F3SJ-B[][][][]P25 *1 F3SJ-B[][][][]N25
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 2,065 F3SJ-B[][][][]P25-01TS *2
Environmental resistance Dia. 25 mm 20 mm 0.2 to 6 m 225 to 1,985 F3SJ-B[][][][]P25-02TS *2

[/fusion_table]

 

 

*1. For S-mark compatible model, the suffix “-S” is added to the model name. (except for models with the suffix
“-01TS” or “-02TS”.)
(Example) F3SJ-E0185P25-S
*2. The F3SJ-B series with the suffix “-01TS” or “02TS” have different functions. Refer to Catalog for details.

Safety Light Curtain Model List

Please contact our sales representative.

F3SJ-B Series (20 mm pitch)
F3SJ-B-01TS Series (20 mm pitch)
F3SJ-B-02TS Series (20 mm pitch)

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Model Number of beams Protective height
[mm] *
PNP output NPN output PNP output NPN output
F3SJ-B0185P25 F3SJ-B0185N25 F3SJ-B0185P25-01TS 8 185
F3SJ-B0225P25 F3SJ-B0225N25 F3SJ-B0225P25-01TS F3SJ-B0225P25-02TS 10 225
F3SJ-B0305P25 F3SJ-B0305N25 F3SJ-B0305P25-01TS F3SJ-B0305P25-02TS 14 305
F3SJ-B0385P25 F3SJ-B0385N25 F3SJ-B0385P25-01TS F3SJ-B0385P25-02TS 18 385
F3SJ-B0465P25 F3SJ-B0465N25 F3SJ-B0465P25-01TS F3SJ-B0465P25-02TS 22 465
F3SJ-B0545P25 F3SJ-B0545N25 F3SJ-B0545P25-01TS F3SJ-B0545P25-02TS 26 545
F3SJ-B0625P25 F3SJ-B0625N25 F3SJ-B0625P25-01TS F3SJ-B0625P25-02TS 30 625
F3SJ-B0705P25 F3SJ-B0705N25 F3SJ-B0705P25-01TS F3SJ-B0705P25-02TS 34 705
F3SJ-B0785P25 F3SJ-B0785N25 F3SJ-B0785P25-01TS F3SJ-B0785P25-02TS 38 785
F3SJ-B0865P25 F3SJ-B0865N25 F3SJ-B0865P25-01TS F3SJ-B0865P25-02TS 42 865
F3SJ-B0945P25 F3SJ-B0945N25 F3SJ-B0945P25-01TS F3SJ-B0945P25-02TS 46 945
F3SJ-B1025P25 F3SJ-B1025N25 F3SJ-B1025P25-01TS F3SJ-B1025P25-02TS 50 1,025
F3SJ-B1105P25 F3SJ-B1105N25 F3SJ-B1105P25-01TS F3SJ-B1105P25-02TS 54 1,105
F3SJ-B1185P25 F3SJ-B1185N25 F3SJ-B1185P25-01TS F3SJ-B1185P25-02TS 58 1,185
F3SJ-B1265P25 F3SJ-B1265N25 F3SJ-B1265P25-01TS F3SJ-B1265P25-02TS 62 1,265
F3SJ-B1345P25 F3SJ-B1345N25 F3SJ-B1345P25-01TS F3SJ-B1345P25-02TS 66 1,345
F3SJ-B1425P25 F3SJ-B1425N25 F3SJ-B1425P25-01TS F3SJ-B1425P25-02TS 70 1,425
F3SJ-B1505P25 F3SJ-B1505N25 F3SJ-B1505P25-01TS F3SJ-B1505P25-02TS 74 1,505
F3SJ-B1585P25 F3SJ-B1585N25 F3SJ-B1585P25-01TS F3SJ-B1585P25-02TS 78 1,585
F3SJ-B1665P25 F3SJ-B1665N25 F3SJ-B1665P25-01TS F3SJ-B1665P25-02TS 82 1,665
F3SJ-B1745P25 F3SJ-B1745N25 F3SJ-B1745P25-01TS F3SJ-B1745P25-02TS 86 1,745
F3SJ-B1825P25 F3SJ-B1825N25 F3SJ-B1825P25-01TS F3SJ-B1825P25-02TS 90 1,825
F3SJ-B1905P25 F3SJ-B1905N25 F3SJ-B1905P25-01TS F3SJ-B1905P25-02TS 94 1,905
F3SJ-B1985P25 F3SJ-B1985N25 F3SJ-B1985P25-01TS F3SJ-B1985P25-02TS 98 1,985
F3SJ-B2065P25 F3SJ-B2065N25 F3SJ-B2065P25-01TS 102 2,065

[/fusion_table]

 

* Protective height (mm) = Total sensor length
Note: 1. The models with the suffix “-01TS” or “-02TS are the PNP type only.
2. The test input logic is inverted for the models with the suffix “-01TS”.
3. Reset mode is fixed with auto reset mode for the models with the suffix “-01TS” or “-02TS”.

 

Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Model PNP output F3SJ-E[][][][]P25
NPN output F3SJ-E[][][][]P25
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25 mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 54
Protective height (PH) 185 to 1,105 mm
Lens diameter Diameter 5 mm
Operating range *2 0.2 to 7 m
Response time
(under stable
light incident
condition)
ON to OFF 15 ms max.
OFF to ON 70 ms max.
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Consumption
current
(no load)
PNP output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max.
Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams:
51 mA max.
NPN output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max.
Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams:
48 mA max.
Light source (emitted
wavelength)
Infrared LED (870 nm)
Effective aperture angle
(EAA)
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the
detection distance is 3 m or over
Safety outputs
(OSSD)
PNP output Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
NPN output Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
Output operation mode Safety output: On when receiving light
Input voltage PNP output Test input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5
OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5
NPN output Test input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA)
OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5
Mutual interference
prevention function
Mutual interference prevention algorithm prevents interference in up to 3 sets.
Test function Self test (at power-ON and at power distribution)
External test (emission stop function by test input)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light
intensity
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z
directions (no delay at resonant frequencies)
Shock resistance Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution degree Pollution degree 3 (IEC 60664-1)
Power cable Connection method: Pull-out type, cable length 3 m
Number of wires: Emitter: 5 wires, receiver: 6 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max. *6
Material Case: Aluminum
Cap: ABS resin, PBT
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Net Weight *7 Weight (g) = (protective height) x 1.59 + 330
Gross Weight *8 Weight (g) = (protective height) x 2.6 + 800
Accessories Instruction Manual, Quick Installation Manual (QIM) *9
Applicable standards *10 IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment)
IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic
Protective Devices)
IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

[/fusion_table]

 

*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User’s Manual (SCHG-733/732).
*7. The net weight is the weight of an emitter and a receiver.
*8. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*9. Mounting brackets and test rod are sold separately.
*10.Refer to Safety Precautions for information about Legislation and Standards.