Specifications

Main
Part Number

TM200CE24R

TM200CE32R

TM200CE40R

Range of product Easy Modicon M200 Easy Modicon M200 Easy Modicon M200
Product or component type Logic controller Logic controller Logic controller
[Us] rated supply voltage 100…240 V AC 100…240 V AC 100…240 V AC
Discrete I/O number 24 32 40
discrete input number I2…I5: 4 fast input I2…I5: 4 fast input I2…I5: 4 fast input
I0, I1, I6, I7: 4 high speed input I0, I1, I6, I7: 4 high speed input I0, I1, I6, I7: 4 high speed input
I8…I13: 6 regular input I8…I19: 12 regular input I8…I23: 16 regular input
discrete output number 10 relay 12 relay 16 relay
Discrete input voltage 24 V 24 V 24 V
Discrete input voltage type DC DC DC
discrete input current 7 mA for input 7 mA for input 7 mA for input
7 mA for fast input
9 mA for high speed input
discrete input logic Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2 Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2 Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2
discrete output voltage 24 V DC 24 V DC 24 V DC
220 V AC 220 V AC 220 V AC
discrete output current 2A 2 A for relay output 2A
Discrete output type Relay normally open Relay normally open Relay normally open
power consumption in VA 52…64 VA at 100…240 V AC (with max I/O) 55…66 VA at 100…240 V AC (with max I/O) 59…69 VA at 100…240 V AC (with max I/O)
Complementary
maximum number of I/O expansion module 4 with 128 discrete output(s) for transistor output 4 with 76 discrete output(s) for relay output 4 with 128 discrete output(s) for transistor output
4 with 74 discrete output(s) for relay output 4 with 80 discrete output(s) for relay output
Supply voltage limits 85…264 V 85…264 V 85…264 V
Network frequency 50/60 Hz 50/60 Hz 50/60 Hz
Inrush current 50 A 50 A 50 A
voltage state 1 guaranteed >= 15 V for input >= 15 V for input >= 15 V for input
voltage state 0 guaranteed <= 5 V for input <= 5 V for input <= 5 V for input
input impedance 3.3 kOhm for discrete input 3.3 kOhm for discrete input 3.3 kOhm for discrete input
response time 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 10 ms turn-on, Q0…Q11 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 10 ms turn-off, Q0…Q11 terminal(s) for output 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input
100 µs turn-off, I2…I5 terminal(s) for fast input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2…I5 terminal(s) for fast input
35 µs turn-on, I2…I5 terminal(s) for fast input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 35 µs turn-on, I2…I5 terminal(s) for fast input
10 ms turn-off, Q0…Q9 terminal(s) for relay output 100 µs turn-off, I2…I5 terminal(s) for fast input 100 µs turn-off, I8…I13 terminal(s) for regular input
10 ms turn-on, Q0…Q9 terminal(s) for relay output 35 µs turn-on, I2…I5 terminal(s) for fast input 35 µs turn-on, I8…I13 terminal(s) for regular input
100 µs turn-off, I8…I13 terminal(s) for regular input 100 µs turn-off, I8…I13 terminal(s) for regular input 10 ms turn-off, Q0…Q15 terminal(s) for relay output
35 µs turn-on, I8…I13 terminal(s) for regular input 35 µs turn-on, I8…I13 terminal(s) for regular input 10 ms turn-on, Q0…Q15 terminal(s) for relay output
125 µs turn-off, I14…I19 terminal(s) for regular input 125 µs turn-off, I14…I23 terminal(s) for regular input
55 µs turn-on, I14…I19 terminal(s) for regular input 55 µs turn-on, I14…I23 terminal(s) for regular input
configurable filtering time 0 ms for input 0 ms for input 0 ms for input
3 ms for input 3 ms for input 3 ms for input
12 ms for input 12 ms for input 12 ms for input
output voltage limits 30 V DC 30 V DC 30 V DC
250 V AC 250 V AC 250 V AC
maximum current per output common 4 A at COM 2 4 A at COM 2 4A
4 A at COM 0 4 A at COM 0
4 A at COM 1 4 A at COM 1
electrical durability 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistive 100000 cycles DC-12, 24 V, 48 W, resistive 100000 cycles DC-12, 24 V, 48 W, resistive
switching frequency 0.1 Hz with maximum load 0.1 Hz with maximum load 0.1 Hz with maximum load
mechanical durability 20000000 cycles for relay output 20000000 cycles for relay output 20000000 cycles for relay output
minimum load 10 mA at 5 V DC for relay output 10 mA at 5 V DC for relay output 10 mA at 5 V DC for relay output
memory capacity 512 byte internal flash for backup of programs 512 byte internal flash for backup of programs 512 byte internal flash for backup of programs
data storage equipment 32 GB micro SD card (optional) 32 GB micro SD card (optional) 32 GB micro SD card (optional)
battery type BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)
backup time 3 years at 25 °C (by interruption of power supply) 3 years at 25 °C (by interruption of power supply) 3 years at 25 °C (by interruption of power supply)
execution time for 1 KInstruction 0.3 ms for event and periodic task 0.3 ms for event and periodic task 0.3 ms for event and periodic task
execution time per instruction 0.2 µs Boolean 0.2 µs Boolean 0.2 µs Boolean
exct time for event task 60 µs response time 60 µs response time 60 µs response time
clock drift <= 90 s/month at 25 °C <= 90 s/month at 25 °C <= 90 s/month at 25 °C
regulation loop Adjustable PID regulator up to 14 simultaneous loops Adjustable PID regulator up to 14 simultaneous loops Adjustable PID regulator up to 14 simultaneous loops
control signal type Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)
Pulse/direction at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode)
Single phase at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode)
CW/CCW at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode)
counting input number 4 fast input (HSC mode) at 100 kHz 32 bits 4 fast input (HSC mode) at 100 kHz 32 bits 4 fast input (HSC mode) at 100 kHz 32 bits
integrated connection type USB port with mini B USB 2.0 connector USB port with mini B USB 2.0 connector USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface Isolated serial link serial 2 with terminal block connector and RS485 interface Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface
Isolated serial link serial 2 with terminal block connector and RS485 interface Isolated serial link serial 2 with terminal block connector and RS485 interface
transmission rate 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB 12 Mbit/s for USB 12 Mbit/s for USB
10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP 10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP
communication port protocol USB port: USB – SoMachine-Network USB port: USB – SoMachine-Network USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Ethernet Modbus TCP/IP: Modbus TCP/IP client/server Ethernet Modbus TCP/IP: Modbus TCP/IP client/server
local signalling 1 LED (green) for PWR 1 LED (green) for PWR 1 LED (green) for PWR
1 LED (green) for RUN 1 LED (green) for RUN 1 LED (green) for RUN
1 LED (red) for module error (ERR) 1 LED (red) for module error (ERR) 1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD) 1 LED (green) for SD card access (SD) 1 LED (green) for SD card access (SD)
1 LED (red) for BAT 1 LED (red) for BAT 1 LED (red) for BAT
1 LED (green) for SL1 1 LED (green) for SL1 1 LED (green) for SL1
1 LED per channel (green) for I/O state 1 LED per channel (green) for I/O state 1 LED per channel (green) for I/O state
2 LEDs (green) for communication (LK/ACT 10/100) 2 LEDs (green) for communication (LK/ACT 10/100)
electrical connection Mini B USB 2.0 connectorfor a programming terminal Mini B USB 2.0 connectorfor a programming terminal Mini B USB 2.0 connectorfor a programming terminal
RJ45 connectorfor connecting Ethernet network removable screw terminal blockfor inputs RJ45 connectorfor connecting Ethernet network
removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal blockfor inputs
removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply removable screw terminal block, 4 terminal(s) for connecting the serial link1
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
maximum cable distance between devices Unshielded cable: <50 m for input Unshielded cable: <50 m for input Unshielded cable: <50 m for input
Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input Shielded cable: <10 m for high speed input Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output Unshielded cable: <150 m for output Unshielded cable: <150 m for output
insulation Non-insulated between inputs Non-insulated between inputs Non-insulated between inputs
Between output and internal logic at 1780 V AC Between output and internal logic at 1780 V AC Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC Between output groups at 1780 V AC Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC Between supply and internal logic at 1780 V AC Between supply and internal logic at 1780 V AC
Between input and internal logic at 500 V AC Between input and internal logic at 500 V AC Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC
Between input groups at 500 V AC Between input groups at 500 V AC Between input groups at 500 V AC
sensor power supply 24 V DC at 250 mA supplied by the controller 24 V DC at 300 mA supplied by the controller 24 V DC at 300 mA supplied by the controller
Marking CE CE CE
mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
Height 90 mm 90 mm 90 mm
Depth 70 mm 70 mm 70 mm
Width 130 mm 175 mm 175 mm
Net weight 0.413 kg 0.504 kg 0.512 kg
Environment
IP degree of protection IP20 with protective cover in place IP20 with protective cover in place IP20 with protective cover in place
Product certifications RCM N/A RCM
IACS E10 IACS E10
cULus CSA
CSA cULus
Standards EN/IEC 61010-2-201 EN/IEC 61131-2 EN/IEC 61010-2-201
EN/IEC 61131-2 EN/IEC 61010-2-201 EN/IEC 61131-2
electromagnetic compatibility Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8 Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8 Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
shock resistance 15 gn for 11 ms 15 gn for 11 ms 15 gn for 11 ms
30 gn for 6 ms 30 gn for 6 ms 30 gn for 6 ms
Immunity to microbreaks 10 ms 10 ms 10 ms
vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.7 Hz on panel mounting 3.5 mm at 5…8.7 Hz on panel mounting 3.5 mm at 5…8.7 Hz on panel mounting
2 gn at 8.7…150 Hz on panel mounting 2 gn at 8.7…150 Hz on panel mounting 2 gn at 8.7…150 Hz on panel mounting
relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in operation) 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage) 10…95 %, without condensation (in storage) 10…95 %, without condensation (in storage)
ambient air temperature for operation 0…55 °C (horizontal installation) 0…55 °C (horizontal installation) 0…55 °C (horizontal installation)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C
Pollution degree <= 2 <= 2 <= 2
Operating altitude 0…2000 m 0…2000 m 0…2000 m
Storage altitude 0…3000 m 0…3000 m 0…3000 m
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 9.497 cm 9.5 cm 9.498 cm
Package 1 Width 13.655 cm 13.8 cm 13.66 cm
Package 1 Length 14.312 cm 18.5 cm 18.72 cm
Package 1 Weight 609.5 g 749.0 g 771 g
Unit Type of Package 2 S03 S03 S03
Number of Units in Package 2 12 12 12
Package 2 Height 30 cm 30.0 cm 30 cm
Package 2 Width 30 cm 30.0 cm 30 cm
Package 2 Length 40 cm 40.0 cm 40 cm
Package 2 Weight 7810 g 9.4 kg 9773 g
Unit Type of Package 3 P12 P06 P12
Number of Units in Package 3 288 96 288
Package 3 Height 95 cm 75.0 cm 95 cm
Package 3 Width 80 cm 80.0 cm 80 cm
Package 3 Length 120 cm 60.0 cm 120 cm
Package 3 Weight 196440 g 83.2 kg 243552 g

 

Weight N/A
Dimensions N/A