Omron E3X-SD / NA -Fiber Sensors- Simple Fiber Amplifier Unit
USD $ 20.68 – USD $ 191.40
Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
Stable Detection
GIGA RAY installed
Realized the highest power and precision in the world.
Capable of stable detection in dusty, oily environments or of minute objects.
Easy Operation
Quick-Tuning installed
By only two clicking operation, sensor optimizes light intensity and sets threshold value automatically.
It is also helpful when light intensity reaches saturation levels.
One key = One function
Easy operation by ‘One key=One function’ and the comfortable ‘Huge’ buttons. No complication.
Digital Model
Bar Display and Adjuster Setting Model
Lineup
Fiber Amplifier Units
Digital Display and Direct Key Setting
Item | Appearance | Connection method | Ratings and Specifications |
Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | — | E3X-SD21 2M | E3X-SD51 2M | |
Wire-saving connector | E3X-SD7 | E3X-SD9 |
*An Amplifier Unit Connector (sold separately) is required.
Bar Display and Adjuster Setting
Item | Appearance | Connection method | Ratings and Specifications |
Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | — | E3X-NA11 2M | E3X-NA41 2M | |
Wire-saving connector | E3X-NA6 | E3X-NA8 | |||
High-speed detection models |
Pre-wired (2 m) | Response time: 20 μs |
E3X-NA11F 2M | E3X-NA41F 2M | |
Water-resistant models |
Pre-wired (2 m) | Degree of protection: IP66 |
E3X-NA11V 2M | E3X-NA41V 2M | |
Connector (M8) | E3X-NA14V | E3X-NA44V |
*2. A Sensor I/O Connector (sold separately) is required.
Accessories (sold separately)
Amplifier Unit Connectors (Required for models for Wire-saving Connectors.)
Note: Protective seals provided.
Item | Appearance | Cable length | No. of conductors | Model |
---|---|---|---|---|
Master Connector | 2 m | 3 | E3X-CN11 | |
Slave Connector | 1 | E3X-CN12 |
Ordering Precautions for Amplifier Units Connectors
A Connector is not provided with the Amplifier Unit.
Refer to the tables at the right when placing an order.
Fiber Amplifier Units | Applicable Connectors (sold separately) | |||
---|---|---|---|---|
Type | NPN | PNP | Master Connector | Slave Connector |
Standard models | E3X-SD7 | E3X-SD9 | E3X-CN11 (3-wire) | E3X-CN12 (1-wire) |
E3X-NA6 | E3X-NA8 |
When Using 5 Amplifier Units
5 Fiber Amplifier Units | + | 1 Master Connector + 4 Slave Connectors |
Sensor I/O Connectors (Required for models with M8 Connectors.)
(Models for Connectors: A Connector is not provided with the Amplifier Unit. Be sure to order a Connector separately.)
Size | Cable specifications | Appearance | Cable type | Model | ||
---|---|---|---|---|---|---|
M8 | Standard cable | Straight connector | 2 m | Four-conductor cable | XS3F-M421-402-A | |
5 m | XS3F-M421-405-A | |||||
L-shaped connector | 2 m | XS3F-M422-402-A | ||||
5 m | XS3F-M422-405-A |
Mounting Brackets
A Mounting Bracket is not provided with the Fiber Amplifier Unit. Order a Mounting Bracket separately if required.
Appearance | Applicable models | Model | Quantity |
---|---|---|---|
E3X-SD[] E3X-NA[] E3X-NA[]F | E39-L143 | 1 | |
E3X-NA[]V | E39-L148 |
End Plate
End Plates are not provided with the Fiber Amplifier Unit. Order End Plates separately if required.
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Specifications
Fiber Amplifier Units
Type | Digital display and direct key setting |
Bar display and adjuster setting | |||
---|---|---|---|---|---|
Standard models | Standard models |
High-speed detection models |
Water-resistant models |
||
Model | E3X-SD[] | E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |
Light source (wavelength) |
Red, 4-element LED (625 nm) | Red, 4-element LED (624 nm) |
Red, 4-element LED (625 nm) |
Red LED (680 nm) | |
Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p): 10% max. | ||||
Power consumption/ Current consumption |
At Power Supply Voltage of 24 VDC 960 mW max./40 mA max. At Power Supply Voltage of 12 VDC 960 mW max./80 mA max. |
At Power Supply Voltage of 24 VDC 840 mW max./35 mA max. At Power Supply Voltage of 12 VDC 420 mW max./35 mA max. |
|||
Control output | Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) Light-ON/Dark-ON mode selector |
Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1 V max.) Light-ON/Dark-ON mode selector. |
|||
Response time | Operate or reset: 200 μs max. *1 | Operate: 20 μs max. Reset: 30 μs max. |
Operate or reset: 200 μs max. *1 |
||
Sensitivity adjustment | UP/DOWN direct key setting, teaching with/without a workpiece, automatic teaching |
8-turn sensitivity adjuster (with indicator) | |||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection |
Power supply reverse polarity protection, output short-circuit protection |
|||
Timer function | — | No timer, OFF-delay timer; or Timer selector (timer time: 40 ms (fixed)) |
|||
Mutual interference prevention |
Up to 5 Amplifiers (optically synchronized) *2 | None | Up to 5 Amplifiers (optically synchronized) *2 |
||
Ambient illumination | Receiver side Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. |
||||
Number of gang- mounted Amplifiers |
16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.) |
||||
Ambient temperature range |
Operating: Groups of 1 to 3 Amplifiers: – 25 °C to 55 °C Groups of 4 to 11 Amplifiers: – 25 °C to 50 °C Groups of 12 to 16 Amplifiers: – 25 °C to 45 °C Storage: – 30 °C to 70 °C (with no icing or condensation) |
||||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) |
Operating: 35% to 85% Storage: 35% to 95% (with no condensation) |
|||
Insulation resistance | 20 MΩ. min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute *3 | ||||
Vibration resistance | Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance | Destruction: 500 m/s2, for 3 times each in X, Y and Z directions | ||||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | IEC 60529 IP66 (with Protective Cover attached) |
|||
Connection method | Pre-wired (standard cable length: 2 m), or connector | ||||
Weight (packed state) *4 | Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g | ||||
Material | Case | Polybutylene terephthalate (PBT) | |||
Cover | Polycarbonate (PC) | Polyethersulfone (PES) |
|||
Accessories | Instruction manual |
Amplifier Unit Connectors (Wire-saving Connectors)
Model | E3X-CN11 | E3X-CN12 | |
---|---|---|---|
Rated current | 2.5 A | ||
Rated voltage | 50 V | ||
Contact resistance | 20 mΩ max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Fiber Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) |
||
Number of insertions | Destruction: 50 times (for connection to the Fiber Amplifier Unit and the adjacent Connector) | ||
Material | Housing | Polybutylene terephthalate (PBT) | |
Contact | Phosphor bronze/gold-plated nickel | ||
Weight (packed state) | Approx. 55 g | Approx. 25 g |
Sensing distance
Threaded Models
Detection method | Sensing direction | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 530 | 160 | 280 |
E32-LT11N 2M | 1,800 | 600 | 900 | |||
Straight | E32-T11R 2M | 560 | 160 | 280 | ||
E32-LT11 2M | 2,100 | 700 | 1,050 | |||
E32-LT11R 2M | 1,800 | 600 | 900 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 25 | 7.5 | 13 |
E32-C21N 2M | 65 | 21 | 32 | |||
M4 | E32-D21N 2M | 170 | 56 | 85 | ||
M6 | E32-C11N 2M | 170 | 50 | 85 | ||
E32-LD11N 2M | 170 | 56 | 85 | |||
Straight | M3 | E32-D21R 2M | 30 | 10 | 15 | |
E32-C31 2M | 80 | 26 | 40 | |||
E32-C31M 1M | ||||||
M4 | E32-D211R 2M | 30 | 10 | 15 | ||
M6 | E32-D11R 2M | 180 | 60 | 90 | ||
E32-CC200 2M | 300 | 100 | 150 | |||
E32-LD11 2M | 180 | 60 | 90 | |||
E32-LD11R 2M | 170 | 56 | 85 |
Cylindrical Models
Detection method | Size | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | 1 dia. | Top-view | E32-T223R 2M | 120 | 36 | 60 |
1.5 dia. | E32-T22B 2M | 200 | 60 | 100 | ||
3 dia. | E32-T12R 2M | 560 | 160 | 280 | ||
Side-view | E32-T14LR 2M | 220 | 66 | 110 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 30 | 10 | 15 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 6 | 2 | 3 | ||
3 dia. | E32-D22R 2M | 30 | 10 | 15 | ||
E32-D221B 2M | 70 | 20 | 35 | |||
E32-D32L 2M | 160 | 50 | 80 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 16 | 4 | 10 |
Flat Models
Detection method | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | Top-view | E32-T15XR 2M | 560 | 160 | 280 |
Side-view | E32-T15YR 2M | 220 | 66 | 110 | |
Flat-view | E32-T15ZR 2M | ||||
Reflective | Top-view | E32-D15XR 2M | 180 | 60 | 90 |
Side-view | E32-D15YR 2M | 40 | 10 | 20 | |
Flat-view | E32-D15ZR 2M |
Sleeve Models
Detection method | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | Side-view | E32-T24R 2M | 60 | 18 | 30 |
E32-T24E 2M | 180 | 36 | 60 | ||
Top-view | E32-T21-S1 2M | 130 | 43 | 65 | |
E32-T33 1M | 40 | 13.5 | 20 | ||
E32-TC200BR 2M | 560 | 160 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 14 | 4.6 | 7 |
E32-D24-S2 2M | 26 | 8 | 13 | ||
Top-view | E32-D43M 1M | 6 | 2 | 3 | |
E32-D331 2M | 3 | 1 | 1.5 | ||
E32-D33 2M | 16 | 4 | 10 | ||
E32-D32-S1 0.5M | 14 | 4 | 7 | ||
E32-D31-S1 0.5M | |||||
E32-DC200F4R 2M | 30 | 10 | 15 | ||
E32-D22-S1 2M | 57 | 19 | 28 | ||
E32-D21-S3 2M | |||||
E32-DC200BR 2M | 180 | 60 | 90 | ||
E32-D25-S3 2M | 57 | 19 | 28 |
Small-spot, Reflective
Type | Spot diameter |
Center distance (mm) |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Variable spot |
0.1 to 0.6 dia. |
6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | ||
0.3 to 1.6 dia. |
10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | |||
Parallel light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | ||
E32-C31N 2M + E39-F3C | ||||||
Integrated lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | ||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | |||
Small- spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | ||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 5 mm. | ||||
E32-C31N 2M + E39-F3A-5 | ||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | ||||
E32-C31N 2M + E39-F3B | ||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | |||
E32-C11N 2M + E39-F18 |
High-power Beam
Type | Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam Integrated lens |
Right-angle | 15° | E32-LT11N 2M | 1,800 | 600 | 900 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 8,400 | 14,000 | |
15° | E32-LT11 2M | 2,100 | 700 | 1,050 | ||
15° | E32-LT11R 2M | 1,800 | 600 | 900 | ||
Side-view | 30° | E32-T14 2M | 3,600 | 1,080 | 1,800 | |
Through-beam models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 3,700 | 1,110 | 2,100 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 2,000 | 3,600 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 1,260 | 2,100 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 2,000 | 3,600 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 440 | 130 | 220 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 1,200 | 2,000 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 2,600 | 4,000 *2 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 720 | 200 | 360 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 2,000 | 720 | 1,650 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 1,560 | 2,900 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 360 | 120 | 200 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 1,800 | 630 | 1,100 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 1,300 | 2,300 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 280 | 84 | 140 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 1,800 | 3,000 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 2,340 | 3,900 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 780 | 260 | 390 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 2,400 | 720 | 1,400 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 3,120 | 4,000 *2 | ||
Reflective Integrated lens |
Top-view | 4° | E32-D16 2M | 800 | 140 | 40 to 400 |
Narrow View
Detection method | Sensing direction |
Aperture angle | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Side-view | 1.5° | E32-A03 2M | 890 | 267 | 445 |
E32-A03-1 2M | ||||||
3.4° | E32-A04 2M | 340 | 102 | 170 | ||
4° | E32-T24SR 2M | 1170 | 360 | 600 | ||
E32-T24S 2M | 1400 | 420 | 700 | |||
E32-T22S 2M | 2000 | 600 | 1000 |
Detection without Background Interference
Detection method |
Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Limited- reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 |
E32-L24S 2M | 0 to 4 | ||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | 5.4 to 8 (center 7.2) | 5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective)
Detection method |
Feature | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Retroreflective Sensors |
Film detection | M3 | E32-C31 2M + E39-F3R + E39-RP37 |
220 | 50 | 75 |
Square | – | E32-R16 2M | 1,500 | 1,000 | 150 to 1,500 | |
Threaded Models | M6 | E32-R21 2M | 10 to 250 | 250 | 10 to 250 | |
Hex-shaped | E32-LR11NP 2M + E39-RP1 |
600 | 200 | 300 |
Transparent Object Detection (Limited-reflective)
Detection method |
Feature | Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Retro- reflective |
Small size | Flat-view | E32- L24S 2M | 0 to 4 | ||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 | ||
Glass substrate alignment, 70°C |
E32-A08 2M | 10 to 20 | ||||
Standard/ long-distance |
E32-A12 2M | 12 to 30 | – | – | ||
Side view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
5.4 to 8 (center 7.2) |
5.4 to 9 (center 7.2) |
|
Glass substrate mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 (center 25) |
Chemical-resistant, Oil-resistant
Detection method |
Type | Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through- beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 * | 1,400 | 2,400 |
Chemical/ oil-resistant |
Top-view | E32-T12F 2M | 3,200 | 960 | 1,600 | |
E32-T11F 2M | 2,100 | 760 | 1,050 | |||
Side-view | E32-T14F 2M | 400 | 120 | 200 | ||
Chemical/oil- resistant at 150°C |
Top-view | E32-T51F 2M | 1,400 | 400 | 700 | |
Reflective | Semiconductors: Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||
Semiconductors: Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Chemical/ oil-resistant |
E32-D12F 2M | 100 | 32 | 50 | ||
Chemical-resistant cable |
E32-D11U 2M | 180 | 60 | 90 |
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Bending-resistant
Detection method | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 1.5 dia. | E32-T22B 2M | 200 | 60 | 100 |
M3 | E32-T21 2M | ||||
M4 | E32-T11 2M | 720 | 200 | 360 | |
Square | E32-T25XB 2M | 150 | 40 | 75 | |
Reflective | 1.5 dia. | E32-D22B 2M | 30 | 10 | 15 |
M3 | E32-D21 2M | ||||
3 dia. | E32-D221B 2M | 70 | 20 | 35 | |
M4 | E32-D21B 2M | ||||
M6 | E32-D11 2M | 180 | 60 | 90 | |
Square | E32-D25XB 2M | 50 | 16 | 25 |
Heat-resistant
Detection method | Heat-resistant temperature | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 100°C | E32-T51R 2M | 400 | 120 | 225 |
150°C | E32-T51 2M | 800 | 240 | 400 | |
200°C | E32-T81R-S 2M | 360 | 100 | 180 | |
350°C | E32-T61-S 2M | 600 | 180 | 300 | |
Reflective | 100°C | E32-D51R 2M | 140 | 42 | 70 |
150°C | E32-D51 2M | 240 | 80 | 120 | |
200°C | E32-D81R 2M | 90 | 27 | 45 | |
300°C | E32-A08H2 2M | 10 to 20 | |||
E32-A09H2 2M | 20 to 30 (center 25) | ||||
350°C | E32-D61 2M | 90 | 27 | 45 | |
400°C | E32-D73 2M | 60 | 18 | 30 |
Area Beam
Detection method | Type | Sensing width | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 800 | 260 | 450 |
E32-T16JR 2M | 700 | 220 | 390 | |||
30 mm | E32-T16WR 2M | 1380 | 400 | 690 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 150 | 50 | 75 |
Liquid-level Detection
Detection method |
Pipe diameter |
Feature | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Tube-mounting | 3.2/6.4/ 9.5 dia. |
Stable residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
||
8 to 10 dia. | Mounting at multi levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm |
|||
No re- strictions |
Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions on diameter) |
|||
Liquid contact (heat-resistant up to 200°C) |
– | – | E32-D82F1 4M | Liquid-contact model |
Vacuum-resistant
Detection method | Heat-resistant temperature |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 120°C | E32-T51V 1M | 200 | – | 100 |
E32-T51V 1M + E39-F1V | 1200 | – | 600 | ||
200°C | E32-T84SV 1M | 500 | – | 250 |
FPD, Semiconductors, and Solar Cells
Detection method |
Application | Operating temperature |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[] E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Limited- reflective |
Glass presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 |
Glass substrate alignment |
E32-A08 2M | 10 to 20 | ||||
300°C | E32-A08H2 2M | |||||
70°C | E32-A12 2M | 12 to 30 | – | – | ||
Glass substrate mapping |
E32-A09 2M | 15 to 38 (center 25) | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | ||||
Wet processes: Cleaning, Resist developing and etching |
60°C | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Wet process: Resist stripping |
85°C | E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||
Through- beam |
Wafer mapping | 70°C | E32-A03 2M | 890 | 267 | 445 |
E32-A03-1 2M | ||||||
E32-A04 2M | 340 | 102 | 170 | |||
E32-T24SR 2M | 1170 | 360 | 600 | |||
E32-T24S 2M | 1400 | 420 | 700 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details