Contact Us:
sales@inosaki.com

Omron E2E-X7D/X14MD/X10D/X20MD Series- Proximity Sensors- Cylindrical

USD $ 33.35USD $ 276.92

SKU N/A Category

Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.

Features

• Standard Sensors for detecting ferrous metals.

• Wide array of variations. Ideal for a variety of applications.

• Models with different frequencies are also available to prevent mutual interference.

• Superior environment resistance with standard cable made of oil-resistant PVC and sensing surface made of material that resists cutting oil.

• Useful to help prevent disconnection. Cable protector provided as a standard feature.

 

2-Wire Models

Pre-wired Models with Oil-resistant Reinforced PUR Cables Added to the Lineup and Easy Differentiation with Orange Head

E2E Features 3

The lineup includes models with Smart click pre-wired connectors for fast connection.

E2E Features 4

UL-recognized Models Available

E2E Features 5

Lineup includes models with self-diagnostic output to provide notification of failures and unstable detection conditions, such as coil burnout.

Contributes to preventive maintenance to keep the line from stopping.

Reduced wiring, fewer resources, and low power consumption contribute to environmentalism.

 

• Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
• Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire
model).

 

3-Wire Models

Wide range of ambient operating temperatures: −40°C to 85°C (M8 to M30 models)

• Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.

Lineup includes models with flexible cable (M8 to M30 models)

• Reduced risk of disconnection in applications with moving parts.

 

Lineup

Shielded DC 2-wire Models with No Self-diagnostic Output

E2E Lineup 2

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
ar-
range-
ment
Appli-
cable
con-
nector
code *2
Model
M8 2 mm M12 Pre-
wired
Smartclick
Connector
Models
(0.3 m)
PUR (increased
oil-resistant)
Yes NO 1: +V,
4: 0 V
H E2E-X2D1-M1TGJ-U 0.3M
NC 1: +V,
2: 0 V
E2E-X2D2-M1TGJ-U 0.3M
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X2D1-M1TGJ 0.3M
Pre-wired
Models
(2 m)
PUR (increased
oil-resistant)
NO E2E-X2D1-U 2M
NC E2E-X2D2-U 2M
PVC
(oil-resistant)
NO E2E-X2D1-N 2M
NC E2E-X2D2-N 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X2D1-M1G
NC 1: +V,
2: 0 V
D E2E-X2D2-M1G
M8
Connector
Models
NO 1: +V,
4: 0 V
I E2E-X2D1-M3G
NC 1: +V,
2: 0 V
E2E-X2D2-M3G
M12 3 mm M12 Pre-
wired
Smartclick
Connector
Models
(0.3 m)
PUR (increased
oil-resistant)
Yes NO 1: +V,
4: 0 V
H E2E-X3D1-M1TGJ-U 0.3M
NC 1: +V,
2: 0 V
E2E-X3D2-M1TGJ-U 0.3M
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X3D1-M1TGJ 0.3M
Pre-wired
Models
(2 m)
PUR (increased
oil-resistant)
NO E2E-X3D1-U 2M
NC E2E-X3D2-U 2M
PVC
(oil-resistant)
NO E2E-X3D1-N 2M *1
NC E2E-X3D2-N 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X3D1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X3D2-M1G
M12
Standard
Pre-wired
Connector
Models
(0.3 m)
PVC
(oil-resistant)
Yes NO 1: +V,
4: 0 V
A E2E-X3D1-M1GJ 0.3M
NC 1: +V,
2: 0 V
D E2E-X3D2-M1GJ 0.3M
No *3 NO (3, 4):
(+V, 0 V)
C E2E-X3D1-M1J-T 0.3M
NC (1, 2):
(+V, 0 V)
D
M18 7 mm M12 Pre-
wired
Smartclick
Connector
Models
(0.3 m)
PUR (increased
oil-resistant)
Yes NO 1: +V,
4: 0 V
H E2E-X7D1-M1TGJ-U 0.3M
NC 1: +V,
2: 0 V
E2E-X7D2-M1TGJ-U 0.3M
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X7D1-M1TGJ 0.3M
Pre-wired
Models
(2 m)
PUR (increased
oil-resistant)
NO E2E-X7D1-U 2M
NC E2E-X7D2-U 2M
PVC
(oil-resistant)
NO E2E-X7D1-N 2M *1
NC E2E-X7D2-N 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X7D1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X7D2-M1G
M12
Standard
Pre-wired
Connector
Models
(0.3 m)
PVC
(oil-resistant)
Yes NO 1: +V,
4: 0 V
A E2E-X7D1-M1GJ 0.3M
NC 1: +V,
2: 0 V
D E2E-X7D2-M1GJ 0.3M
No *3 NO (3, 4):
(+V, 0 V)
C E2E-X7D1-M1J-T 0.3M
NC (1, 2):
(+V, 0 V)
D E2E-X7D2-M1J-T 0.3M
M30 10 mm M12 Pre-
wired
Smartclick
Connector
Models
(0.3 m)
PUR (increased
oil-resistant)
Yes NO 1: +V,
4: 0 V
H E2E-X10D1-M1TGJ-U 0.3M
NC 1: +V,
2: 0 V
E2E-X10D2-M1TGJ-U 0.3M
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X10D1-M1TGJ 0.3M
Pre-wired
Models
(2 m)
PUR (increased
oil-resistant)
NO E2E-X10D1-U 2M
NC E2E-X10D2-U 2M
PVC
(oil-resistant)
NO E2E-X10D1-N 2M *1
NC E2E-X10D2-N 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X10D1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X10D2-M1G
M12
Standard
Pre-wired
Connector
Models
(0.3 m)
PVC
(oil-resistant)
Yes NO 1: +V,
4: 0 V
A E2E-X10D1-M1GJ 0.3M
PVC
(oil-resistant)
NC 1: +V,
2: 0 V
D E2E-X10D2-M1GJ 0.3M
PVC
(oil-resistant)
No *3 NO (3, 4):
(+V, 0 V)
C E2E-X10D1-M1J-T 0.3M
PVC
(oil-resistant)
NC (1, 2):
(+V, 0 V)
D E2E-X10D2-M1J-T 0.3M

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]D15 (example: E2E-X3D15-N 2M).
*2. Refer to Data Sheet for details.
*3. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage).
Refer to Data Sheet.

Shielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output

E2E Lineup 4

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Connection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
ar-
range-
ment
Appli-
cable
con-
nector
code *
Model
M8 2 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
PVC
(oil-
resistant)
Yes NO 1: +V,
4: 0 V
G E2E-X2D1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X2D2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X2D1-US 2M
NC E2E-X2D2-US 2M
M12 3 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X3D1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X3D2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X3D1-US 2M
NC E2E-X3D2-US 2M
M18 7 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X7D1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X7D2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X7D1-US 2M
NC E2E-X7D2-US 2M
M30 10 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X10D1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X10D2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X10D1-US 2M
NC E2E-X10D2-US 2M

[/fusion_table]

* Refer to Data Sheet for details.

Unshielded DC 2-Wire Models with No Self-diagnosis Output

E2E Lineup 6

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
ar-
range-
ment
Appli-
cable
con-
nector
code *2
Model
M8 4 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
Yes NO E2E-X4MD1 2M
NC E2E-X4MD2 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X4MD1-M1G
NC 1: +V,
2: 0 V
D E2E-X4MD2-M1G
M8
Connector
Models
NO 1: +V,
4: 0 V
I E2E-X4MD1-M3G
NC 1: +V,
2: 0 V
E2E-X4MD2-M3G
M12 8 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X8MD1-M1TGJ 0.3M
Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X8MD1 2M *1
NC E2E-X8MD2 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X8MD1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X8MD2-M1G
M12 Standard
Pre-wired
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
A E2E-X8MD1-M1GJ 0.3M
NC 1: +V,
2: 0 V
D
M18 14 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X14MD1-M1TGJ 0.3M
Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X14MD1 2M *1
NC E2E-X14MD2 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X14MD1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X14MD2-M1G
M12 Standard
Pre-wired
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
A E2E-X14MD1-M1GJ 0.3M
NC 1: +V,
2: 0 V
D E2E-X14MD2-M1GJ 0.3M
M30 20 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
G E2E-X20MD1-M1TGJ 0.3M
Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X20MD1 2M *1
NC E2E-X20MD2 2M
M12
Connector
Models
NO 1: +V,
4: 0 V
A E2E-X20MD1-M1G *1
NC 1: +V,
2: 0 V
D E2E-X20MD2-M1G
M12 Standard
Pre-wired
Connector
Models (0.3 m)
PVC
(oil-resistant)
NO 1: +V,
4: 0 V
A E2E-X20MD1-M1GJ 0.3M
NC 1: +V,
2: 0 V
D

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]D15 (example: E2E-X8MD15 2M).
*2. Refer to Data Sheet for details.

Unshielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output

E2E Lineup 8

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
ar-
range-
ment
Appli-
cable
con-
nector
code *
Model
M8 4 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
PVC
(oil-
resistant)
Yes NO 1: +V,
4: 0 V
G E2E-X4MD1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X4MD2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X4MD1-US 2M
NC E2E-X4MD2-US 2M
M12 8 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X8MD1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X8MD2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X8MD1-US 2M
NC E2E-X8MD2-US 2M
M18 14 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X14MD1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X14MD2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X14MD1-US 2M
NC E2E-X14MD2-US 2M
M30 20 mm M12 Pre-wired
Smartclick
Connector
Models (0.3 m)
NO 1: +V,
4: 0 V
G E2E-X20MD1-M1TGJ-US 0.3M
NC 1: +V,
2: 0 V
E2E-X20MD2-M1TGJ-US 0.3M
Pre-wired
Models (2 m)
NO E2E-X20MD1-US 2M
NC E2E-X20MD2-US 2M

[/fusion_table]

* Refer to Data Sheet for details.

Shielded DC 2-Wire Models with Self-diagnosis Output

E2E Lineup 10

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
arrangement
Appli-
cable
con-
nector
code *2
Model
M12 3 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
Yes NO E2E-X3D1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X3D1S-M1
M18 7 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
E2E-X7D1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X7D1S-M1
M30 10 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
E2E-X10D1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X10D1S-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]D15S (example: E2E-X3D15S 2M).
*2. Refer to Data Sheet for details.

Unshielded DC 2-Wire Models with Self-diagnosis Output

E2E Lineup 12

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Po-
lar-
ity
Opera-
tion
mode
Pin
arrangement
Appli-
cable
con-
nector
code *2
Model
M12 8 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
Yes NO E2E-X8MD1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X8MD1S-M1
M18 14 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
E2E-X14MD1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X14MD1S-M1
M30 20 mm Pre-wired
Models
(2 m)
PVC
(oil-
resistant)
E2E-X20MD1S 2M *1
M12
Connector
Models
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X20MD1S-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]MD15S (example: E2E-X8MD15S 2M).
*2. Refer to Data Sheet for details.

Connector Pin Assignments of DC 2-Wire Models

• The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.)
• The following models with conventional connector pin assignments are available as well. (Only NO Models can be used.) The cable at the right should also be used if the XW3D-P[]55-G11/XW3B-P[]55-G11 Connector Junction Box is already being used.

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Cable length Model
500 mm XS2W-D421-BY1

[/fusion_table]

E2E Lineup 15

Models with conventional connector pin assignments are available as well.

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Appearance Model
NO Applicable connector
code *
NC Applicable connector
code *
449_lu_8_1
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
449_lu_8_2
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D

[/fusion_table]

* Refer to Data Sheet for details.

AC 2-Wire Models Shielded Models

E2E Lineup 18

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Appear-
ance
Sensing
distance
Connection
method
Cable
specifications
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M8 1.5 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X1R5Y1 2M
NC E2E-X1R5Y2 2M
M12 2 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X2Y1 2M *1
NC E2E-X2Y2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X2Y1-M1
NC (1, 2): (AC, AC) F E2E-X2Y2-M1
M18 5 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X5Y1 2M *1
NC E2E-X5Y2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X5Y1-M1
NC (1, 2): (AC, AC) F E2E-X5Y2-M1
M30 10 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X10Y1 2M *1
NC E2E-X10Y2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X10Y1-M1
NC (1, 2): (AC, AC) F E2E-X10Y2-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]Y[]5 (example: E2E-X5Y15 2M).
*2. Refer to Data Sheet for details.

Unshielded Models

E2E Lineup 20

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Appear-
ance
Sensing
distance
Connection
method
Cable
specifications
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M8 2 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X2MY1 2M
NC E2E-X2MY2 2M
M12 5 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X5MY1 2M *1
NC E2E-X5MY2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X5MY1 2M
NC (1, 2): (AC, AC) F E2E-X5MY2-M1
M18 10 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X10MY1 2M *1
NC E2E-X10MY2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X10MY1-M1
NC (1, 2): (AC, AC) F E2E-X10MY2-M1
M30 18 mm Pre-wired
Models (2 m)
PVC
(oil-resistant)
NO E2E-X18MY1 2M *1
NC E2E-X18MY2 2M
M12 Connector
Models
NO (3, 4): (AC, AC) E E2E-X18MY1-M1
NC (1, 2): (AC, AC) F E2E-X18MY2-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]MY[]5 (example: E2E-X5MY15 2M).
*2. Refer to Data Sheet for details.

AC 2-Wire Models Shielded Models (There are no unshielded models.)

E2E Lineup 22

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Appear-
ance
Sensing
distance
Connection
method
Cable
specifications
Operation
mode
Pin
arrange-
ment
Applicable
connector
code
Model
M12 3 mm Pre-wired Models (2 m) PVC (oil-resistant) NO E2E-X3T1 2M
M18 7 mm Pre-wired Models (2 m) PVC (oil-resistant) E2E-X7T1 2M
M30 10 mm Pre-wired Models (2 m) PVC (oil-resistant) E2E-X10T1 2M

[/fusion_table]

3-Wire Models

Shielded DC 3-Wire Models

E2E Lineup 24

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Opera-
tion
mode
Pin
arrange-
ment
Appli-
cable
con-
nector
code *2
Model
NPN output PNP output
M8 1.5 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X1R5E1 2M E2E-X1R5F1 2M
PVC (oil-
resistant)
NC E2E-X1R5E2 2M E2E-X1R5F2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X1R5E1-M1 E2E-X1R5F1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X1R5E2-M1 E2E-X1R5F2-M1
M8
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
I E2E-X1R5E1-M3 E2E-X1R5F1-M3
NC 1: +V, 3: 0 V,
2: Control
output
E2E-X1R5E2-M3 E2E-X1R5F2-M3
M12 2 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X2E1 2M *1 E2E-X2F1 2M *1
NC E2E-X2E2 2M E2E-X2F2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X2E1-M1 E2E-X2F1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X2E2-M1 E2E-X2F2-M1
M18 5 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X5E1 2M *1 E2E-X5F1 2M *1
NC E2E-X5E2 2M E2E-X5F2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X5E1-M1 E2E-X5F1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X5E2-M1 E2E-X5F2-M1
M30 10 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X10E1 2M *1 E2E-X10F1 2M
NC E2E-X10E2 2M E2E-X10F2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X10E1-M1 E2E-X10F1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X10E2-M1 E2E-X10F2-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[][][]5 (example: E2E-X5E15 2M).
*2. Refer to Data Sheet for details.

Unshielded DC 3-Wire Models

E2E Lineup 26

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Ap-
pear-
ance
Sensing
distance
Con-
nection
method
Cable
specifi-
cations
Opera-
tion
mode
Pin
arrange-
ment
Appli-
cable
con-
nector
code *2
Model
NPN output PNP output
M8 2 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X2ME1 2M E2E-X2MF1 2M
NC E2E-X2ME2 2M E2E-X2MF2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X2ME1-M1 E2E-X2MF1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X2ME2-M1 E2E-X2MF2-M1
M8
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
I E2E-X2ME1-M3 E2E-X2MF1-M3
NC 1: +V, 3: 0 V,
2: Control
output
E2E-X2ME2-M3 E2E-X2MF2-M3
M12 5 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X5ME1 2M *1 E2E-X5MF1 2M
NC E2E-X5ME2 2M E2E-X5MF2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X5ME1-M1 E2E-X5MF1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X5ME2-M1 E2E-X5MF2-M1
M18 10 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X10ME1 2M *1 E2E-X10MF1 2M
NC E2E-X10ME2 2M E2E-X10MF2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X10ME1-M1 E2E-X10MF1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X10ME2-M1 E2E-X10MF2-M1
M30 18 mm Pre-wired
Models
(2 m)
PVC (oil-
resistant)
NO E2E-X18ME1 2M *1 E2E-X18MF1 2M
NC E2E-X18ME2 2M E2E-X18MF2 2M
M12
Connector
Models
NO 1: +V, 3: 0 V,
4: Control
output
B E2E-X18ME1-M1 E2E-X18MF1-M1
NC 1: +V, 3: 0 V,
2: Control
output
D E2E-X18ME2-M1 E2E-X18MF2-M1

[/fusion_table]

*1. Models with different frequencies are also available. The model number is E2E-X[]M[][]5 (example: E2E-X5ME15 2M).
*2. Refer to Data Sheet for details.

Sensor I/O Connectors (Sockets on One Cable End)

Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Connector Applicable Proximity Sensor
model number
Screw Appearance
*1
Cable length 2m Cable length 5m
CablConnector
model number
CablConnector
model number
M12 Straight XS2F-D421-DA0-F XS2F-D421-GA0-F E2E-X[]D1-M1G(J)
L-shape XS2F-D422-DA0-F XS2F-D422-GA0-F
Straight XS2F-D421-DC0-F XS2F-D421-GC0-F E2E-X[]E1-M1
E2E-X[]F1-M1
L-shape XS2F-D422-DC0-F XS2F-D422-GC0-F
Straight XS2F-D421-DD0 XS2F-D421-GD0 E2E-X[]D1-M1J-T
E2E-X[]D1-M1
L-shape XS2F-D422-DD0 XS2F-D422-GD0 E2E-X[]D1-M1J-T
E2E-X[]D1-M1
Straight XS2F-D421-D80-F XS2F-D421-G80-F E2E-X[]D2-M1G(J)
E2E-X[]D2-M1J-T
E2E-X[]D2-M1
E2E-X[]D1S-M1
E2E-X[]E2-M1
E2E-X[]F2-M1
L-shape XS2F-D422-D80-F XS2F-D422-G80-F E2E-X[]D2-M1G(J)
E2E-X[]D2-M1J-T
E2E-X[]D2-M1
E2E-X[]D1S-M1
E2E-X[]E2-M1
E2E-X[]F2-M1
Straight XS2F-A421-DB0-F XS2F-A421-GB0-F E2E-X[]Y1-M1
L-shape XS2F-A422-DB0-F XS2F-A422-GB0-F
Straight XS2F-A421-D90-F XS2F-A421-G90-F E2E-X[]Y2-M1
Smartclick Connector,
Straight
XS5F-D421-D80-F XS5F-D421-G80-F E2E-X[]D1-M1TGJ(-US)
E2E-X[]D2-M1TGJ-US
Smartclick Connector,
Straight Oil-resistant
Reinforced Cables
XS5F-D421-D80-P XS5F-D421-G80-P E2E-X[]D1-M1TGJ-U
E2E-X[]D2-M1TGJ-U
M8 Straight XS3F-M421-402-A XS3F-M421-405-A E2E-X[]D1-M3G
E2E-X[]D2-M3G
E2E-X[]E1-M3
E2E-X[]F1-M3
E2E-X[]E2-M3
E2E-X[]F2-M3
L-shape XS3F-M422-402-A XS3F-M422-405-A E2E-X[]D1-M3G
E2E-X[]D2-M3G
E2E-X[]E1-M3
E2E-X[]F1-M3
E2E-X[]E2-M3
E2E-X[]F2-M3

[/fusion_table]

Note: Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details and for information on Cable length and Robotics Cables.
*1. Images of straight and L-shaped connectors.
E2E Lineup 30
*2. Refer to Connection Diagrams on Data Sheet for information on Proximity Sensor and I/O Connector connections.

E2E-X[]D[] DC 2-Wire Models

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M8 M12
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X2D[] E2E-X4MD[] E2E-X3D[] E2E-X8MD[]
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10%
Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
8 × 8 × 1 mm
Iron,
20 × 20 × 1 mm
Iron,
12 × 12 × 1 mm
Iron,
30 × 30 × 1 mm
Response frequency *2 1.5 kHz 1 kHz 0.8 kHz
Power supply voltage
(operating voltage range)
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)
US Models and Connector Models Used as UL-certified Models:
12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
Leakage current 0.8 mA max.
Control
output
Load current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Residual
voltage *4
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
Indicators D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Diagnostic output delay 0.3 to 1 s
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient temperature
range
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
±10% max. of sensing distance at 23°C in
the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 10 times each in X,
Y, and Z directions
Destruction: 1,000 m/s2 10 times each in X,
Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
Connector Models (Standard cable length: 0.3 m)
Weight
(packed
state)
Pre-wired
Models
Approx. 60 g Approx. 70 g
Pre-wired
Connector
Models
Approx. 40 g
Connector
Models
Approx. 15 g Approx. 25 g
Materi-
als
Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M18 M30
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X7D[] E2E-X14MD[] E2E-X10D[] E2E-X20MD[]
Sensing distance 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *1 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency *2 0.5 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage range)
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)
US Models and Connector Models Used as UL-certified Models:
12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
Leakage current 0.8 mA max.
Control
output
Load current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Residual
voltage *4
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
Indicators D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Diagnostic output delay 0.3 to 1 s
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient temperature
range
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
Connector Models (Standard cable length: 0.3 m)
Weight
(packed
state)
Pre-wired
Models
Approx. 130 g Approx. 175 g
Pre-wired
Connector
Models
Approx. 70 g Approx. 110 g
Connector
Models
Approx. 40 g Approx. 90 g
Materi-
als
Case Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. For the information on UL-certified connector models, refer to your OMRON website.
*4. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 26 for details.)

E2E-X[]Y[] AC 2-Wire Models

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M8 M12
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X1R5Y[] E2E-X2MY[] E2E-X2Y[] E2E-X5MY[]
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
8 × 8 × 1 mm
Iron, 12 × 12 × 1 mm Iron,
15 × 15 × 1 mm
Response frequency 25 Hz
Power supply voltage
(operating voltage range) *1
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
Leakage current 1.7 mA max.
Control
output
Load current *2 5 to 100 mA 5 to 200 mA
Residual voltage Refer to Engineering Data on Data Sheet.
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits Surge suppressor
Ambient temperature range
*1 *2
Operating/Storage: -25 to 70°C
(with no icing or condensation)
Operating/Storage: -40 to 85°C
(with no icing or condensation)
Ambient humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
±15% max. of sensing distance at 23°C
in the temperature range of -40 to 85°C,
±10% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 10 times each in
X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each
in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
(packed
state)
Pre-wired Models
Model
Approx. 60 g Approx. 70 g
Connector Models Approx. 15 g Approx. 25 g
Materials Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M18 M30
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X5Y[] E2E-X10MY[] E2E-X10Y[] E2E-X18MY[]
Sensing distance 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency 25 Hz
Power supply voltage
(operating voltage range) *1
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
Leakage current 1.7 mA max.
Control
output
Load current *2 5 to 300 mA
Residual voltage Refer to Engineering Data on Data Sheet.
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits Surge suppressor
Ambient temperature range
*1 *2
Operating/Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
(packed
state)
Pre-wired Models
Model
Approx. 130 g Approx. 175 g
Connector Models Approx. 40 g Approx. 90 g
Materials Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of 5 to 200 mA max.

E2E-X[]T1 AC/DC 2-Wire Models

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M12 M18 M30
Shielded Shielded
Model E2E-X3T1 E2E-X7T1 E2E-X10T1
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response
frequency
*1
DC 1 kHz 0.5 kHz 0.4 kHz
AC 25 Hz
Power supply voltage
(operating voltage range) *2
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
Leakage current DC: 1 mA max.
AC: 2 mA max.
Control
output
Load current 5 to 100 mA
Residual
voltage
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Indicators Operation indicator (red), Setting indicator (green)
Operation mode
(with sensing object
approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.)
Protection circuits Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 80 g Approx. 140 g Approx. 190 g
Materials Case Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.

SPECIFICATIONS

E2E-X[]E[]/F[] DC 3-Wire Models

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M8 M12
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X1R5E[]/F[] E2E-X2ME[]/F[] E2E-X2E[]/F[] E2E-X5ME[]/F[]
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
8 × 8 × 1 mm
Iron, 12 × 12 × 1 mm Iron,
15 × 15 × 1 mm
Response frequency *1 2 kHz 0.8 kHz 1.5 kHz 0.4 kHz
Power supply voltage
(operating voltage range) *2
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC)
Connector Models Used as UL-certified Models: 12 to 24 VDC,
ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
Current consumption 13 mA max.
Control
output
Load current *2 200 mA max.
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient temperature range
*2
Operating/Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 10 times each in
X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each
in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
(packed
state)
Pre-wired Models Approx. 65 g Approx. 75 g
Connector
Models
Approx. 15 g Approx. 25 g
Materials Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Size M18 M30
Shielded Shielded Unshielded Shielded Unshielded
Model E2E-X5E[]/F[] E2E-X10ME[]/F[] E2E-X10E[]/F[] E2E-X18ME[]/F[]
Sensing distance 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron,
18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency *1 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage range) *2
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC)
Connector Models Used as UL-certified Models: 12 to 24 VDC,
ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
Current consumption 13 mA max.
Control
output
Load current *2 200 mA max.
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient temperature range
*2
Operating/Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
(packed
state)
Pre-wired Models Approx. 150 g Approx. 195 g
Connector
Models
Approx. 40 g Approx. 90 g
Materials Case Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

[/fusion_table]

Additional information

Select your currency