Contact Us:
sales@inosaki.com

Domestic TeSys Deca GV2 – GV2ME – Thermal Magnetic Motor Circuit Breakers – Schneider Circuit Breakers

$ 31.28$ 37.49

Specifications

Main information
Part Number GV2ME05C GV2ME07C GV2ME08C GV2ME10C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product name TeSys GV2 TeSys GV2 TeSys GV2 TeSys GV2
product short name GV2ME GV2ME GV2ME GV2ME
product type Breaker Breaker Breaker Breaker
Applications Motor protection Motor protection Motor protection Motor protection
number of poles 3P 3P 3P 3P
Additional information
Grid type AC AC AC AC
Network frequency 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2
control type (Push) button (Push) button (Push) button (Push) button
installation method Rail installation Rail installation Rail installation Rail installation
installation location horizontal vertical horizontal vertical Vertical horizontal vertical
horizontal direction
Motor power (kW) 0.00…0.37 kW at 230 V AC 50/60 Hz 0.37 kW at 230 V AC 50/60 Hz 0.75 kW at 230 V AC 50/60 Hz 1.1 kW at 230 V AC 50/60 Hz
0.00…0.37 kW at 400 V AC 50/60 Hz 0.75 kW at 400 V 1.5 kW at 400 V 2.2 kW at 400 V
0.00…0.37 kW at 415 V AC 50/60 Hz 0.75 kW at 415 V 1.5 kW at 415 V 2.2 kW at 415 V
0.37 kW at 440 V AC 50/60Hz 1.1 kW at 440 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz
Rated current [In] 1A 2.5A 4A 6.3A
Trip unit type Thermomagnetic Thermomagnetic Thermomagnetic Thermomagnetic
Electromagnetic trip current 13A 33.5A 51A 78A
Thermal overload protection setting range 0.63…1A 1.6…2.5 A 2.5…4A 4…6.3A
isolation function Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04 0.5 J IK04 0.5 J IK04 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2
power consumption per pole 2.5W 2.5W 2.5W 2.5W
Mechanical life 100000 times 100000 times 100000 times 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h 25 cyc/h 25 cyc/h 25 cyc/h
specified load Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operating short-circuit breaking capacity [Ics] 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2
high 89mm 89mm 89 mm 89mm
width 44.5 mm 44.5 mm 44.5 mm 44.5 mm
depth 78.2 mm 78.2 mm 78.2 mm 78.2 mm
product weight 0.26kg 0.26kg 0.26kg 0.26kg
Environment
Standards compliant GB 14048.4 GB 14048.4 GB 14048.4 GB 14048.4
IEC 60947-1 IEC 60947-1 IEC 60947-1 IEC 60947-1
IEC 60947-2 IEC 60947-2 IEC 60947-2 IEC 60947-2
IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1
certified product CCC CCC CCC CCC
CE UKCA UKCA UKCA
UKCA CE CE CE
Protective measures TH TH TH TH
IP protection class IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet
-20…60 °C Body -20…60 °C Body -20…60 °C Body -20…60 °C Body
storage environment temperature -40…80°C -40…80°C -40…80°C -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m <= 2000m <= 2000m <= 2000m
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 4.716 cm 4.869 cm 4.799 cm 4.94cm
Package 1 Width 8.214 cm 8.195 cm 8.242 cm 8.13cm
Package 1 Length 9.056 cm 9.019 cm 9.08 cm 9.02 cm
Package 1 Weight 229.0g 258.0g 258.0g 271.875g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 32 32 32 32
Package 2 Height 15.0cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 7.752kg 8.608 kg 8.648kg 9.092kg
Unit Type of Package 3 P06 P06 P06 P06
Number of Units in Package 3 640 640 640 640
Package 3 Height 90.0cm 90.0cm 90.0cm 90.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 165.04kg 182.16kg 182.96kg 191.84kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number GV2ME14C GV2ME16C GV2ME20C GV2ME22C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product name TeSys GV2 TeSys GV2 TeSys GV2 TeSys GV2
product short name GV2ME GV2ME GV2ME GV2ME
product type Breaker Breaker Breaker Breaker
Applications Motor protection Motor protection Motor protection Motor protection
number of poles 3P 3P 3P 3P
Additional information
Grid type AC AC AC AC
Network frequency 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2
control type (Push) button (Push) button (Push) button (Push) button
installation method Rail installation Rail installation Rail installation Rail installation
installation location horizontal vertical horizontal vertical Vertical Vertical
horizontal direction horizontal direction
Motor power (kW) 2.2 kW at 230 V AC 50/60 Hz 3 kW at 230 V AC 50/60 Hz 4 kW at 230 V AC 50/60 Hz 5.5 kW at 230 V AC 50/60 Hz
4 kW at 400 V 5.5 kW at 400 V 7.5 kW at 400 V 11 kW at 400 V
4 kW at 415 V 5.5 kW at 415 V 9 kW at 415 V 11 kW at 415 V
4 kW at 440 V AC 50/60 Hz 7.5 kW at 440 V AC 50/60 Hz 9 kW at 440 V AC 50/60 Hz 11 kW at 440 V AC 50/60 Hz
Rated current [In] 10A 14A 18A 25A
Trip unit type Thermomagnetic Thermomagnetic Thermomagnetic Thermomagnetic
Electromagnetic trip current 138A 170A 223A 327A
Thermal overload protection setting range 6…10A 9…14A 13…18A 20…25A
isolation function Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04 0.5 J IK04 0.5 J IK04 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2
power consumption per pole 2.5W 2.5W 2.5W 2.5W
Mechanical life 100000 times 100000 times 100000 times 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h 25 cyc/h 25 cyc/h 25 cyc/h
specified load Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operating short-circuit breaking capacity [Ics] 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89mm 89mm 89mm 89 mm
width 44.5 mm 44.5 mm 44.5 mm 44.5 mm
depth 78.2 mm 78.2 mm 78.2 mm 78.2 mm
product weight 0.26kg 0.26kg 0.26kg 0.26kg
Environment
Standards compliant GB 14048.4 GB 14048.4 GB 14048.4 GB 14048.4
IEC 60947-1 IEC 60947-1 IEC 60947-1 IEC 60947-1
IEC 60947-2 IEC 60947-2 IEC 60947-2 IEC 60947-2
IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1
certified product CCC CCC CCC CCC
UKCA UKCA UKCA UKCA
CE CE CE CE
Protective measures TH TH TH TH
IP protection class IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet
-20…60 °C Body -20…60 °C Body -20…60 °C Body -20…60 °C Body
storage environment temperature -40…80°C -40…80°C -40…80°C -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m <= 2000m <= 2000m <= 2000m
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 4.87cm 5.3 cm 4.78cm 4.88cm
Package 1 Width 8.18cm 9.0cm 8.18cm 8.09cm
Package 1 Length 9.0cm 9.6cm 9.03 cm 9.02 cm
Package 1 Weight 272.01g 278.28g 284.625g 284.843g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 32 32 32 32
Package 2 Height 15.0cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 9.079kg 9.297 kg 9.5kg 9.507 kg
Unit Type of Package 3 P06 P06 P06 P06
Number of Units in Package 3 640 640 640 640
Package 3 Height 90.0cm 90.0cm 90.0cm 90.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 191.58kg 195.94kg 200.0kg 200.14kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number GV2ME32C
Product Series TeSys Deca
product name TeSys GV2
product short name GV2ME
product type Breaker
Applications Motor protection
number of poles 3P
Additional information
Grid type AC
Network frequency 50/60 Hz conforming to IEC 60947-2
control type (Push) button
installation method Rail installation
installation location horizontal vertical
Motor power (kW) 7.5 kW at 230 V AC 50/60 Hz
15 kW at 400 V
15 kW at 415 V
15 kW at 440 V AC 50/60 Hz
Rated current [In] 32A
Trip unit type Thermomagnetic
Electromagnetic trip current 416A
Thermal overload protection setting range 24…32A
isolation function Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2
power consumption per pole 2.5W
Mechanical life 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h
specified load Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 10 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operating short-circuit breaking capacity [Ics] 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89mm
width 44.5 mm
depth 78.2 mm
product weight 0.26kg
Environment
Standards compliant GB 14048.4
IEC 60947-1
IEC 60947-2
IEC 60947-4-1
certified product CCC
UKCA
CE
Protective measures TH
IP protection class IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet
-20…60 °C Body
storage environment temperature -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m
Packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.78cm
Package 1 Width 8.15cm
Package 1 Length 9.03 cm
Package 1 Weight 279.6g
Unit Type of Package 2 S02
Number of Units in Package 2 32
Package 2 Height 15.0cm
Package 2 Width 30.0cm
Package 2 Length 40.0cm
Package 2 Weight 9.339 kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 90.0cm
Package 3 Width 60.0cm
Package 3 Length 80.0cm
Package 3 Weight 196.784kg
Contract warranty
Warranty 18 months

Additional information

Weight N/A
Dimensions N/A
Amp, A

, , , , , , , ,

Related Products

IDS-USB 3-Adapter cable-Straight-Screwable-0
Banner_Q12RP6RQ3
IDS Camera IDS imaging ueye camera
PRL30-10DP2
Omron_Couplings_E69-[]_1
$ 23.00 - $ 90.39
M5
- $ 0.00
Select your currency