DFS60B-BEMB10000 – Incremental encoders – SICK Encoders
USD $ 481.80
SKU: SICK 1056480
Incremental encoders generate information about position, angle, and rotation counts. The resolution is defined in the number of lines or pulses per rotation, which the encoder transmits to the control unit for each rotation. The current position can be determined by the control unit by counting these pulses. A reference run can be necessary when switching on the machine.
Part Number: 1056480
Encoders Model: DFS60B-BEMB10000
OEM Spec Ref
Performance
Pulses per revolution | 10,000 1) |
Measure the step distance | 90° electricity/number of pulses per turn |
Measures pulse width deviation, not the number of “binary” pulses | ± 0.01° |
Error limit | ± 0.05° |
- 1) See Maximum Speed Observation.
Interfaces
Communication interface | Incremental |
Communication interface details | TTL / HTL |
Factory settings | Factory-programmed output level TTL |
Number of signal channels | 6 channels |
0-Set function via hardware pins | ✔ |
0-SET function | High level activation, L = 0 – 3 V, H = 4,0 – Us V 1) |
Programmable/parameterized | ✔ |
Initialization time | 32 ms 2)
30 ms |
Output frequency | ≤ 600 kHz |
Load current | ≤ 30 mA |
power consumption | ≤ 0.7 W (no load) |
- 1) Only for device variants with M23 plugs (with electrical connections M, U, V and W).
- 2) Mechanical zero pulse width.
Electrical data
Connection type | Male connector, M23, 12-pin, axial |
Supply voltage | 4.5 … 32 V |
Reference signal, quantity | 1 |
Reference signal, location | 90°, electrical, logically connected to A and B |
Reverse polarity protection | ✔ |
Short-circuit protection at the output | ✔ 1) 2) |
MTTFd: Dangerous Failure Interval | 300 years (EN ISO 13849-1) 3) |
- 1) TTL programming, ≥ 5.5 V: short circuit with another channel or GND, maximum permissible time 30 s.
- 2) HTL programming or TTL ≥ 5.5 V: short circuit with another channel, US or GND, maximum permissible time 30 s.
- 3) This product is a standard product and not a safety component made in accordance with the Machinery Directive. Calculations are based on component load rating, average ambient temperature of 40°C, frequency of use of 8760 hours/year. All electronic faults are considered dangerous. For more information, see the documentation number 8015532.
Mechanical data
Mechanical specifications | Blind hole hollow shaft |
Shaft diameter | 12 mm |
weight | + 0.2 kg |
Material, shaft | stainless steel |
Material, flange | aluminium |
Material, shell | Die-cast aluminum |
Starting torque | 0.8 Ncm (+20 °C) |
Operating torque | 0.6 Ncm (+20 °C) |
Allows static shaft displacement | ± 0.3 mm (radial)
± 0.5 mm (axial) |
Dynamic axis displacement is allowed | ± 0.2 mm (radial)
± 0.1 mm (axial) |
Operating speed | ≤ 6,000 min⁻¹ 1) |
Inertia | 40 gcm² |
Bearing service life | 3.6 x 10^10 rpm |
angular acceleration | ≤ 500,000 rad/s² |
- 1) When designing the operating temperature range, it is important to note that the self-heating is 3.3 K / 1,000 rpm.
Weight | 0.320 kg |
---|