Contact Us:
sales@inosaki.com

H3DT-N/-L – Multi-range, Multi-mode Timer – Omron Analog Timers

$ 72.22$ 99.13

SKU N/A Category

List of Models

Supply voltage Control output H3DT-N/H3DT-L
Standard
Eight-mode Timer
Expansion
Eight-mode Timer
24 to 240 VAC/DC Contact output, DPDT
(time-limit DPDT, or timelimit SPDT +
instantaneous SPDT)
Changed using a switch.
Model H3DT-N2 H3DT-L2
Contact output, SPDT (time-limit SPDT) H3DT-N1 H3DT-L1

 

Model Structure

Model Operating modes Terminal
block
Input type Output type Mounting
method
Safety standards
H3DT-N2 A2: ON Delay (Power ON Delay)
B3: Flicker OFF Start (Power ON Start)
B4: Flicker ON Start (Power ON Start)
D: Signal OFF Delay
E2: Interval (Power ON Start)
E3: Signal OFF Interval
F2: Cumulative (ON Delay)
F3: Cumulative (Interval)
10 terminals Voltage
input
Relay,
DPDT
DIN Track
mounting
cULus
(UL 508 CSA C22.2 No.14)
CCC
LR
EN 61812-1
IEC 60664-1 4 kV/2
H3DT-N1 8 terminals Relay,
SPDT
H3DT-L2 A: ON Delay (Signal ON Delay)
B: Flicker OFF Start (Signal Start)
B2: Flicker ON Start (Signal Start)
C: Signal ON/OFF Delay
E: Interval (Signal Start)
G: Signal ON/OFF Delay
J: One-shot Output (Signal Start)
J2: One-shot Output (Power ON Start)
10 terminals Relay,
DPDT
H3DT-L1 8 terminals Relay,
SPDT

 

 

Specifications 

Time Ranges

Time range setting 0.1 s 1 s 10 s 1 min 10 min 1 h 10 h 100 h
Set time range 0.1 to 1.2 s 1 to 12 s 10 to 120 s 1 to 12 min 10 to
120 min
1 to 12 h 10 to 120 h 100 to
1,200 h
Scale numbers 12

 

 

Ratings

Power supply voltage *1 24 to 240 VAC/DC, 50/60 Hz *2
Allowable voltage fluctuation
range
85% to 110% of rated voltage
Power reset Minimum power-OFF time: 0.1 s
Reset voltage 10% of rated voltage
Voltage input 24 to 240 VAC/DC
High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC
*3
Power
consumption
H3DT-N2/-L2 At 240 VAC: 2.3 VA max., at 240 VDC: 1.0 W max.,
at 24 VDC: 0.3 W max.
H3DT-N1/-L1 At 240 VAC: 2.0 VA max., at 240 VDC: 0.9 W max.,
at 24 VDC: 0.3 W max.
Rated Insulation Voltage 250 VAC
Control output Contact output:
5 A at 250 VAC with resistive load (cosφ = 1),
5 A at 30 VDC with resistive load *5,
0.15 A max. at 125 VDC with resistive load,
0.1A max. at 125 VDC with L/R of 7 ms.
The minimum applicable load is 10 mA at 5 VDC (P reference value).
Contact materials: Ag-alloy + Gold plating
(Recommended fuse: BLN5 (Littelfuse) or 0216005MXEP)
Ambient operating
temperature
-20 to 60°C (with no icing)
Storage temperature -40 to 70°C (with no icing)
Surrounding air operating
humidity
25% to 85%

 

*1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.5 A.
Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output,
such as a sensor.
*2. DC ripple: 20% max.
*3. The power consumption is for after the Timer times out in mode F2 for the H3DT-N and mode A for the H3DT-L.
The maximum power consumption is given, including the current consumed by the input circuit.

 

Characteristics

Accuracy of operating
time
±1% of FS max. (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% of FS ±0.05 s max.
Minimum input signal
width
50 ms (start input)
Influence of voltage ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range)
Influence of
temperature
±2% of FS max. (±2% ±10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between charged metal part and operating section:
2,900 VAC 50/60 Hz for 1 min.
Between control output terminals and operating circuit:
2,000 VAC 50/60 Hz for 1 min.
Between contacts not located next to each other:
1,000 VAC 50/60 Hz for 1 min.
Impulse withstand
test voltage
5 kV between power terminals, 7.4 kV between conductor terminal and
operating section
Noise immunity Square-wave noise generated by noise simulator
(pulse width: 100 ns/1 μs, 1-ns rise): ±1.5 kV
Static immunity Malfunction: 4 kV, Destruction: 8 kV
Vibration
resistance
Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions
Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Shock
resistance
Destruction 1,000 m/s2 3 times each in 6 directions
Malfunction 100 m/s2 3 times each in 6 directions
Life
expectancy
Mechanical 10 million operations min. (under no load at 1,800 operations/h)
Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
Degree of protection IP30 (Terminal block: IP20)
Weight Approx. 100 g

Related Products

M5
$ 0.33 - $ 0.83
1605944636(1)
PHOENIX CONTACT_END COVER_3211634
SICK_sensor_Inductive proximity sensor_IQG_IQ40-20BPSKC0K
IDS_camera_U3-3560XCP_1
$ 280.38 - $ 305.89
SICK_Inductive Proximity Sensors_IME18-12NPSZC0S
Select your currency