Contact Us:
sales@inosaki.com

TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 170A – Schneider Contactors & Reversing Contactors

$ 135.70$ 144.44

Specifications

Main
Part Number LC1D17000F7C LC1D17000M7C LC1D17000Q7C
Product Series TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor
product short name LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-1
AC-3
AC-3e
AC-1
AC-3
AC-3e
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 300 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Rated operating current [Ie] 200 A 60 °C) at <= 440 V AC AC-1 for power circuits
170 A 60 °C) at <= 440 V AC AC-3 for power circuits
200 A 60 °C) at <= 440 V AC AC-1 for power circuits
170 A 60 °C) at <= 440 V AC AC-3 for power circuits
200 A 60 °C) at <= 440 V AC AC-1 for power circuits
170 A 60 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 110V AC 50/60Hz 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 55 kW at 220/240 V AC 50/60 Hz (AC-3)
90 kW at 380/400 V AC 50/60 Hz (AC-3)
100 kW at 415/440 V AC 50/ 60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60Hz (AC-3)
55 kW at 220/240 V AC 50/60 Hz (AC-3)
90 kW at 380/400 V AC 50/60 Hz (AC-3)
100 kW at 415/440 V AC 50/ 60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60Hz (AC-3)
55 kW at 220/240 V AC 50/60 Hz (AC-3)
90 kW at 380/400 V AC 50/60 Hz (AC-3)
100 kW at 415/440 V AC 50/ 60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60Hz (AC-3)
model LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO
protection cap None None None
Conventional thermal current [Ith] 200 A at <60 °C for power circuits 200 A at <60 °C for power circuits 200 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 250 A at <40 °C – 10 min for power circuit
1400 A at <40 °C – 1 s for power circuit
1200 A at <40 °C – 10 s for power circuit
580 A at <40 °C – 1 minute for power circuit
250 A at <40 °C – 10 min for power circuit
1400 A at <40 °C – 1 s for power circuit
1200 A at <40 °C – 10 s for power circuit
580 A at <40 °C – 1 minute for power circuit
250 A at <40 °C – 10 min for power circuit
1400 A at <40 °C – 1 s for power circuit
1200 A at <40 °C – 10 s for power circuit
580 A at <40 °C – 1 minute for power circuit
Fuses for use with relays 315 A gG at <= 690 V with type 1 suitable power circuit
250 A gG at <= 690 V with type 2 suitable power circuit
315 A gG at <= 690 V with type 1 suitable power circuit
250 A gG at <= 690 V with type 2 suitable power circuit
315 A gG at <= 690 V with type 1 suitable power circuit
250 A gG at <= 690 V with type 2 suitable power circuit
average impedance 0.6 mΩ – Ith 200 A 50 Hz for power circuits 0.6 mΩ – Ith 200 A 50 Hz for power circuits 0.6 mΩ – Ith 200 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles 8 Mcycles
Electrical life 0.6 Mcycles 250 A AC-1 Ue <= 440 V
0.8 Mcycles 150 A AC-3 Ue <= 440 V
1.5 Mcycles 90 A AC-3 Ue 660/690 V
0.6 Mcycles 250 A AC-1 Ue <= 440 V
0.8 Mcycles 150 A AC-3 Ue <= 440 V
1.5 Mcycles 90 A AC-3 Ue 660/690 V
0.6 Mcycles 250 A AC-1 Ue <= 440 V
0.8 Mcycles 150 A AC-3 Ue <= 440 V
1.5 Mcycles 90 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.5 Uc -40…55 °C release 50/60 Hz
0.8…1.15 Uc -40…55 °C run 50/60 Hz
0.3…0.5 Uc -40…55 °C release 50/60 Hz
0.8…1.15 Uc -40…55 °C run 50/60 Hz
0.3…0.5 Uc -40…55 °C release 50/60 Hz
0.8…1.15 Uc -40…55 °C run 50/60 Hz
(~50Hz pickup) power consumption (VA) 280…350 VA 50 Hz 0.9 20 °C)
280…350 VA 60 Hz 0.9 20 °C)
280…350 VA 50 Hz 0.9 20 °C)
280…350 VA 60 Hz 0.9 20 °C)
280…350 VA 50 Hz 0.9 20 °C)
280…350 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 2…18 VA 50 Hz 0.9 20 °C)
2…18 VA 60 Hz 0.9 20 °C)
2…18 VA 50 Hz 0.9 20 °C)
2…18 VA 60 Hz 0.9 20 °C)
2…18 VA 50 Hz 0.9 20 °C)
2…18 VA 60 Hz 0.9 20 °C)
heat dissipation 3…4.5 W at 50/60 Hz 3…4.5 W at 50/60 Hz 3…4.5 W at 50/60 Hz
action time 20…35 ms closed
40…75 ms open
20…35 ms closed
40…75 ms open
20…35 ms closed
40…75 ms open
operating frequency 1200 cycles/h at <60 °C 1200 cycles/h at <60 °C 1200 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: flexible wire with wire terminal
Control circuit: screw fastening1 1…2.5 mm² Cable selection: flexible wire with wire terminal
Power circuit: bus terminal : Solid busbar cross-section: 5 x 25 mm
Power circuit: Terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: Flexible without wire terminals
Power circuit: Terminal 2 10…50 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord without wire terminals
Power circuit: terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord with wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable Option: Flexible with wire terminal Power
Circuit: Terminal 1 10…120 mm² Lug Ø: 25 mm Cable Option: Solid No With wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable option: Solid without wire terminals
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Flexible Without wire terminal
control circuit: bolt fastening2 1…2.5 mm² Cable selection: flexible wire without wire terminal
control circuit: screw fastening1 1…2.5 mm² cable selection: rigid wire without wire terminal
control Circuit: Bolt-on2 1…2.5 mm² Cable selection: Solid without cable terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: flexible wire with wire terminal
Control circuit: screw fastening1 1…2.5 mm² Cable selection: flexible wire with wire terminal
Power circuit: bus terminal : Solid busbar cross-section: 5 x 25 mm
Power circuit: Terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: Flexible without wire terminals
Power circuit: Terminal 2 10…50 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord without wire terminals
Power circuit: terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord with wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable Option: Flexible with wire terminal Power
Circuit: Terminal 1 10…120 mm² Lug Ø: 25 mm Cable Option: Solid No With wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable option: Solid without wire terminals
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Flexible Without wire terminal
control circuit: bolt fastening2 1…2.5 mm² Cable selection: flexible wire without wire terminal
control circuit: screw fastening1 1…2.5 mm² cable selection: rigid wire without wire terminal
control Circuit: Bolt-on2 1…2.5 mm² Cable selection: Solid without cable terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: flexible wire with wire terminal
Control circuit: screw fastening1 1…2.5 mm² Cable selection: flexible wire with wire terminal
Power circuit: bus terminal : Solid busbar cross-section: 5 x 25 mm
Power circuit: Terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: Flexible without wire terminals
Power circuit: Terminal 2 10…50 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord without wire terminals
Power circuit: terminal 1 10…120 mm² Lug outer diameter Ø: 25 mm Cable selection: flexible cord with wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable Option: Flexible with wire terminal Power
Circuit: Terminal 1 10…120 mm² Lug Ø: 25 mm Cable Option: Solid No With wire terminals
Power circuit: Terminal 2 10…50 mm² Lug O.D. Ø: 25 mm Cable option: Solid without wire terminals
Control circuit: Bolt tight1 1…2.5 mm² Cable option: Flexible Without wire terminal
control circuit: bolt fastening2 1…2.5 mm² Cable selection: flexible wire without wire terminal
control circuit: screw fastening1 1…2.5 mm² cable selection: rigid wire without wire terminal
control Circuit: Bolt-on2 1…2.5 mm² Cable selection: Solid without cable terminals
Tightening torque Control circuit: 1.2 Nm by bolting with screwdriver Ø 6 Flat
control circuit: 1.2 Nm by bolting with screwdriver No. 2 Phillips screw
power circuit: 12 Nm by bolting hexagonal 4 mm
power circuit: 12 Nm by cable connection Hexagonal 13 mm screw: M8
Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2
Control circuit: 1.2 Nm by bolting with screwdriver Ø 6 Flat
control circuit: 1.2 Nm by bolting with screwdriver No. 2 Phillips screw
power circuit: 12 Nm by bolting hexagonal 4 mm
power circuit: 12 Nm by cable connection Hexagonal 13 mm screw: M8
Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2
Control circuit: 1.2 Nm by bolting with screwdriver Ø 6 Flat
control circuit: 1.2 Nm by bolting with screwdriver No. 2 Phillips screw
power circuit: 12 Nm by bolting hexagonal 4 mm
power circuit: 12 Nm by cable connection Hexagonal 13 mm screw: M8
Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2
Auxiliary contact type Does not contain Does not contain Does not contain
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
environment
standard GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
high 158 mm 158 mm 158 mm
width 120 mm 120 mm 120 mm
depth 136 mm 136 mm 136 mm
Product Weight 2.5 kg 2.5 kg 2.5 kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 16.45cm 16.876 cm 16.817 cm
Package 1 Width 17.82cm 18.038 cm 18.006 cm
Package 1 Length 20.966 cm 20.683 cm 20.429 cm
Package 1 Weight 2428.5g 2416.2g 2410.0g
Unit Type of Package 2 P06 P06 P06
Number of Units in Package 2 Twenty four Twenty four Twenty four
Package 2 Height 60.0cm 60.0cm 60.0cm
Package 2 Width 60.0cm 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm 80.0cm
Package 2 Weight 70.68 kg 70.38 kg 70.23 kg
contract warranty