EasyPact TVS – LRE – Type E 3 Poles Thermal Overload Relay – Schneider Thermal Overload Relays

$ 78.20$ 387.32

Specifications

Main
Part Number LRE482N LRE483N LRE484N
Product Series Compact Compact Compact
product name EasyPact TVS EasyPact TVS EasyPact TVS
product type Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay Type E 3 pole thermal overload relay
product short name LRE LRE LRE
Relay application Motor protection Motor protection Motor protection
phase loss sensitivity 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1
Additional information
The scope of products LC1E120…630 LC1E160…630 LC1E200…630
Network Type AC AC AC
operating frequency 50/60Hz 50/60Hz 50/60Hz
installation method Mounting on
the bottom plate of the contactor, with special accessories
Mounting on the bottom plate of the contactor
, with special accessories
Mounting on the bottom plate of the contactor
, with special accessories
Thermal release drag rating Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1 Class 10A conforming to IEC 60947-4-1
Signal indication function Relay Trip Indicator Relay Trip Indicator Relay Trip Indicator
Relay setting range 84…135A 124…198A 146…234A
Trip threshold 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1 1.14 ± 0.06 In conforming to IEC 60947-4-1
Conventional thermal current [Ith] 5 A for control circuits 5 A for control circuits 5 A for control circuits
Rated working voltage [Ue] <= 690V AC <= 690V AC <= 690V AC
Fuses for use with relays 5 A gG for control circuits
200 A gG for power circuits
160 A aM for power circuits
5 A gG for control circuits
250 A gG for power circuits
200 A aM for power circuits
5 A gG for control circuit
315 A gG for power circuit
250 A aM for power circuit
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 6kV 6kV 6kV
control type Stop: Red (push) button
Reset: Green (push) button
Stop: Red (push) button
Reset: Green (push) button
Stop: Red (push) button
Reset: Green (push) button
Temperature compensation -20…60°C -20…60°C -20…60°C
Phase spacing 34.8 mm 40 mm 48 mm
Wiring capacity Terminal busbar cross-section: 3 x 18 mm Terminal busbar cross-section: 3 x 20 mm Terminal busbar cross-section: 3 x 25 mm
Tightening torque 27.5 Nm Via lug screw: M8 27.5 Nm Via lug screw: M8 35 Nm via lug screw: M10
high 141 mm 131 mm 134 mm
width 180 mm 180mm 180 mm
depth 134 mm 134 mm 134 mm
Product Weight 1.67kg 1.67kg 1.67kg
environment
Standards compliant IEC 60947-4-1
GB 14048
IEC 60947-4-1
GB 14048
GB 14048
IEC 60947-4-1
certified product CCC CCC CCC
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
IP protection class IP00 conforming to IEC 60529 IP00 conforming to IEC 60529 IP00 conforming to IEC 60529
ambient temperature -20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
-20…60 °C without derating according to IEC 60947-4-1
-20…70 °C with derating
storage environment temperature -60…80°C -60…80°C -60…80°C
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60068-2-1 850 °C conforming to IEC 60068-2-1 850 °C conforming to IEC 60068-2-1
Shock and vibration resistance Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7
Shock resistance: 6 gn conforming to IEC 60068-2-6
Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7
Shock resistance: 6 gn conforming to IEC 60068-2-6
Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7
Shock resistance: 6 gn conforming to IEC 60068-2-6
Insulation properties 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5 6 kV at 50 Hz conforming to IEC 60255-5
electromagnetic compatibility Impulse withstand voltage: 6 kV conforming to IEC 60801-5 Impulse withstand voltage: 6 kV conforming to IEC 60801-5 Impulse withstand voltage: 6 kV conforming to IEC 60801-5
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 16cm 16cm 16cm
Package 1 Width 17.7cm 17.7cm 17.7cm
Package 1 Length 27.5cm 27.5cm 27.5cm
Package 1 Weight 2813g 2811.25g 2846.25 g
Unit Type of Package 2 S03 S03 S03
Number of Units in Package 2 2 2 2
Package 2 Height 30cm 30cm 30cm
Package 2 Width 30cm 30cm 30cm
Package 2 Length 40cm 40cm 40cm
Package 2 Weight 6.184 kg 6.18kg 6.25kg
Unit Type of Package 3 P06 P06 P06
Number of Units in Package 3 16 16 16
Package 3 Height 75cm 75cm 75cm
Package 3 Width 60cm 60cm 60cm
Package 3 Length 80cm 80cm 80cm
Package 3 Weight 59.468 kg 59.44 kg 60kg