SIMATIC ET 200SP Open Controllers – CPU 1515SP PC – Siemens PLC
USD $ 2,616.91 – USD $ 5,002.04
Out of stock
ET 200SP Open Controller, CPU 1515SP PC, is a rugged, compact control system that combines the functionality of an ET 200SP controller with a PC-based platform. The CPU offers the entire value added of the ET 200SP system, the S7-1500 controller family and the TIA world combined.
The controller can be used to control special and series machines, or to control plants in a distributed configuration. The standard user program is generated in the TIA Portal. The controller is especially suitable for machines with high data volumes, e.g. for quality assurance with camera inspection and image transmission, or printer connection.
The CPU 1515SP PC develops its full potential particularly:
- When special automation functions have to be integrated using the C or C++ programming languages
- When a close connection of Windows software to the software controller is required, or
- When large volumes of data have to be stored.
The CPU 1515SP PC + HMI with pre-installed WinCC Runtime Advanced is offered for additional HMI functionality. This enables control and visualization to be integrated on a single device.
Siemens Logic Controllers ET 200SP Product Specifications:
Article number | 6ES7677-2AA31-0EB0 | 6ES7677-2AA41-0FB0 | |
CPU 1515SP PC 4GB | CPU 1515SP PC 4GB | ||
General information | |||
Product type designation | CPU 1515SP PC | CPU 1515SP PC | |
HW functional status | FS06 | FS05 | |
Firmware version | V2.1 | V2.1 | |
Engineering with | |||
● STEP 7 TIA Portal configurable/integrated from version | V14 SP1 | V14 SP1 | |
Installed software | |||
● Visualization | No | No | |
● Control | S7-1500 Software Controller CPU 1505SP V2.1 | S7-1500 Software Controller CPU 1505SP V2.1 | |
Configuration control | |||
via dataset | Yes | Yes | |
Control elements | |||
Mode selector switch | 1 | 1 | |
Supply voltage | |||
Rated value (DC) | 24 V | 24 V | |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | |
Reverse polarity protection | Yes | Yes | |
Mains buffering | |||
● Mains/voltage failure stored energy time | 5 ms | 5 ms | |
Input current | |||
Current consumption (rated value) | 1.5 A; Full processor load, incl. ET 200SP modules and using USB | 1.5 A; Full processor load, incl. ET 200SP modules and using USB | |
Current consumption (in no-load operation), typ. | 0.6 A | 0.6 A | |
Inrush current, max. | 4.7 A; Rated value | 4.7 A; Rated value | |
Power | |||
Active power input, max. | 36 W; incl. ET 200SP modules and using USB | 36 W; incl. ET 200SP modules and using USB | |
Infeed power to the backplane bus | 8.75 W | 8.75 W | |
Power loss | |||
Power loss, typ. | 15 W; without ET 200SP modules and without using USB | 15 W; without ET 200SP modules and without using USB | |
Processor | |||
Processor type | Dual-Core 1 GHz, AMD G Series APU T40E | Dual-Core 1 GHz, AMD G Series APU T40E | |
Memory | |||
Type of memory | DDR3-SDRAM | DDR3-SDRAM | |
Main memory | 4 GB RAM | 4 GB RAM | |
CFast memory card | Yes; 30 GB flash memory | Yes; 30 GB flash memory | |
SIMATIC memory card required | No | No | |
Work memory | |||
● integrated (for program) | 1 Mbyte | 1 Mbyte | |
● integrated (for data) | 5 Mbyte | 5 Mbyte | |
● integrated (for CPU function library of CPU Runtime) | 10 Mbyte | 10 Mbyte | |
Load memory | |||
● integrated (on PC mass storage) | 320 Mbyte | 320 Mbyte | |
Backup | |||
● with UPS | Yes; all memory areas declared retentive | Yes; all memory areas declared retentive | |
● with non-volatile memory | Yes | Yes | |
CPU processing times | |||
for bit operations, typ. | 10 ns | 10 ns | |
for word operations, typ. | 12 ns | 12 ns | |
for fixed point arithmetic, typ. | 16 ns | 16 ns | |
for floating point arithmetic, typ. | 64 ns | 64 ns | |
CPU-blocks | |||
Number of elements (total) | 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements | 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements | |
DB | |||
● Number, max. | 5 999; Number range: 1 to 65535 | 5 999; Number range: 1 to 65535 | |
● Size, max. | 5 Mbyte | 5 Mbyte | |
FB | |||
● Number, max. | 5 998; Number range: 1 to 65535 | 5 998; Number range: 1 to 65535 | |
● Size, max. | 512 kbyte | 512 kbyte | |
FC | |||
● Number, max. | 5 999; Number range: 1 to 65535 | 5 999; Number range: 1 to 65535 | |
● Size, max. | 512 kbyte | 512 kbyte | |
OB | |||
● Size, max. | 1 048 kbyte | 1 048 kbyte | |
● Number of free cycle OBs | 100 | 100 | |
● Number of time alarm OBs | 20 | 20 | |
● Number of delay alarm OBs | 20 | 20 | |
● Number of cyclic interrupt OBs | 20 | 20 | |
● Number of process alarm OBs | 50 | 50 | |
● Number of DPV1 alarm OBs | 3 | 3 | |
● Number of isochronous mode OBs | 1 | 1 | |
● Number of technology synchronous alarm OBs | 2 | 2 | |
● Number of startup OBs | 100 | 100 | |
● Number of asynchronous error OBs | 4 | 4 | |
● Number of synchronous error OBs | 2 | 2 | |
● Number of diagnostic alarm OBs | 1 | 1 | |
Nesting depth | |||
● per priority class | 24 | 24 | |
Counters, timers and their retentivity | |||
S7 counter | |||
● Number | 2 048 | 2 048 | |
Retentivity | |||
— adjustable | Yes | Yes | |
IEC counter | |||
● Number | Any (only limited by the main memory) | Any (only limited by the main memory) | |
Retentivity | |||
— adjustable | Yes | Yes | |
S7 times | |||
● Number | 2 048 | 2 048 | |
Retentivity | |||
— adjustable | Yes | Yes | |
IEC timer | |||
● Number | Any (only limited by the main memory) | Any (only limited by the main memory) | |
Retentivity | |||
— adjustable | Yes | Yes | |
Data areas and their retentivity | |||
Retentive data area (incl. timers, counters, flags), max. | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes | |
Flag | |||
● Size, max. | 16 kbyte | 16 kbyte | |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | 8; 8 clock memory bit, grouped into one clock memory byte | |
Data blocks | |||
● Retentivity adjustable | Yes | Yes | |
● Retentivity preset | No | No | |
Local data | |||
● per priority class, max. | 64 kbyte; max. 16 KB per block | 64 kbyte; max. 16 KB per block | |
Address area | |||
Number of IO modules | 8 192 | 8 192 | |
I/O address area | |||
● Inputs | 32 kbyte; All inputs are in the process image | 32 kbyte; All inputs are in the process image | |
● Outputs | 32 kbyte; All outputs are in the process image | 32 kbyte; All outputs are in the process image | |
of which per assigned PC interface | |||
— Inputs (volume) | 8 kbyte | 8 kbyte | |
— Outputs (volume) | 8 kbyte | 8 kbyte | |
Subprocess images | |||
● Number of subprocess images, max. | 32 | 32 | |
Hardware configuration | |||
Integrated power supply | Yes | Yes | |
Number of distributed IO systems | 20 | 20 | |
Number of DP masters | |||
● Via CM | 1 | 1 | |
Rack | |||
● Modules per rack, max. | 64; CPU 1515SP PC + 64 modules + server module | 64; CPU 1515SP PC + 64 modules + server module | |
● Number of lines, max. | 1 | 1 | |
PtP CM | |||
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | |||
Clock | |||
● Type | Hardware clock | Hardware clock | |
● Hardware clock (real-time) | Yes; Resolution: 1 s | Yes; Resolution: 1 s | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | 10 s; Typ.: 2 s | |
Clock synchronization | |||
● supported | Yes | Yes | |
● to DP, master | No | No | |
● on Ethernet via NTP | Yes | Yes | |
● on Windows clock, slave | Yes | Yes | |
Interfaces | |||
Number of industrial Ethernet interfaces | 2 | 2 | |
Number of PROFINET interfaces | 1 | 1 | |
Number of PROFIBUS interfaces | 1 | 1 | |
Number of RS 485 interfaces | 1; Via CM DP module | 1; Via CM DP module | |
Number of USB interfaces | 3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously | 3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously | |
Number of SD card slots | 1 | 1 | |
Video interfaces | |||
● Graphics interface | 1x DVI-I | 1x DVI-I | |
1. Interface | |||
Interface type | PROFINET | PROFINET | |
automatic detection of transmission rate | Yes | Yes | |
Autonegotiation | Yes | Yes | |
Autocrossing | Yes | Yes | |
Number of connections | 88 | 88 | |
Interface types | |||
● RJ 45 (Ethernet) | Yes; Via BusAdapter BA 2x RJ45 | Yes; Via BusAdapter BA 2x RJ45 | |
— Transmission rate, max. | 100 Mbit/s | 100 Mbit/s | |
— Industrial Ethernet status LED | Yes | Yes | |
● Number of ports | 2 | 2 | |
● integrated switch | Yes | Yes | |
● BusAdapter (PROFINET) | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | |
Protocols | |||
● PROFINET IO Controller | Yes | Yes | |
● PROFINET IO Device | Yes | Yes | |
● SIMATIC communication | Yes | Yes | |
● Open IE communication | Yes | Yes | |
● Web server | Yes | Yes | |
PROFINET IO Controller | |||
Services | |||
— Isochronous mode | Yes | Yes | |
— shortest clock pulse | 500 µs | 500 µs | |
— IRT | Yes | Yes | |
— Prioritized startup | Yes; Max. 32 PROFINET devices | Yes; Max. 32 PROFINET devices | |
— Number of connectable IO Devices, max. | 128 | 128 | |
— Of which IO devices with IRT, max. | 64 | 64 | |
— of which in line, max. | 64 | 64 | |
— Number of connectable IO Devices for RT, max. | 128 | 128 | |
— of which in line, max. | 128 | 128 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | 8 | |
— IO Devices changing during operation (partner ports), supported | Yes | Yes | |
— Number of IO Devices per tool, max. | 8 | 8 | |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for IRT | |||
— for send cycle of 500 µs | 500 µs to 8 ms | 500 µs to 8 ms | |
— for send cycle of 1 ms | 1 ms to 16 ms | 1 ms to 16 ms | |
— for send cycle of 2 ms | 2 ms to 32 ms | 2 ms to 32 ms | |
— for send cycle of 4 ms | 4 ms to 64 ms | 4 ms to 64 ms | |
— With IRT and parameterization of “odd” send cycles | Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) | Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) | |
Update time for RT | |||
— for send cycle of 500 µs | 500 µs to 256 ms | 500 µs to 256 ms | |
— for send cycle of 1 ms | 1 ms to 512 ms | 1 ms to 512 ms | |
— for send cycle of 2 ms | 2 ms to 512 ms | 2 ms to 512 ms | |
— for send cycle of 4 ms | 4 ms to 512 ms | 4 ms to 512 ms | |
PROFINET IO Device | |||
Services | |||
— Isochronous mode | No | No | |
— IRT | Yes | Yes | |
— Prioritized startup | Yes | Yes | |
— Shared device | Yes | Yes | |
— Number of IO Controllers with shared device, max. | 4 | 4 | |
2. Interface | |||
Interface type | Integrated Ethernet interface | Integrated Ethernet interface | |
automatic detection of transmission rate | Yes | Yes | |
Autonegotiation | Yes | Yes | |
Autocrossing | Yes | Yes | |
Interface types | |||
● RJ 45 (Ethernet) | Yes; Integrated | Yes; Integrated | |
— Transmission rate, max. | 1 000 Mbit/s | 1 000 Mbit/s | |
— Industrial Ethernet status LED | No | No | |
● Number of ports | 1 | 1 | |
3. Interface | |||
Interface type | PROFIBUS with CM DP | PROFIBUS with CM DP | |
Number of connections | 44 | 44 | |
Interface types | |||
● RS 485 | Yes | Yes | |
Protocols | |||
● PROFIBUS DP master | Yes | Yes | |
● PROFIBUS DP slave | Yes | Yes | |
● SIMATIC communication | Yes | Yes | |
PROFIBUS DP master | |||
● Number of DP slaves, max. | 125 | 125 | |
Services | |||
— Equidistance | No | No | |
— Isochronous mode | No | No | |
Interface types | |||
RS 485 | |||
● Transmission rate, max. | 12 Mbit/s | 12 Mbit/s | |
Protocols | |||
PROFIsafe | No | No | |
Number of connections | |||
● Number of connections, max. | 88 | 88 | |
● Number of connections reserved for ES/HMI/web | 10 | 10 | |
● Number of S7 routing paths | 16 | 16 | |
Redundancy mode | |||
Media redundancy | |||
— MRP | Yes | Yes | |
— MRPD | Yes | Yes | |
— Switchover time on line break, typ. | 200 ms | 200 ms | |
— Number of stations in the ring, max. | 50 | 50 | |
SIMATIC communication | |||
● PG/OP communication | Yes | Yes | |
● S7 routing | Yes | Yes | |
● S7 communication, as server | Yes | Yes | |
● S7 communication, as client | Yes | Yes | |
● User data per job, max. | 64 kbyte | 64 kbyte | |
Open IE communication | |||
● TCP/IP | Yes | Yes | |
— Data length, max. | 64 kbyte | 64 kbyte | |
● ISO-on-TCP (RFC1006) | Yes | Yes | |
— Data length, max. | 64 kbyte | 64 kbyte | |
● UDP | Yes | Yes | |
— Data length, max. | 1 472 kbyte | 1 472 kbyte | |
● SNMP | Yes | Yes | |
● DCP | Yes | Yes | |
● LLDP | Yes | Yes | |
Web server | |||
● HTTP | Yes; Via Windows and PROFINET interface | Yes; Via Windows and PROFINET interface | |
● HTTPS | Yes; Only via PROFINET interface | Yes; Only via PROFINET interface | |
OPC UA | |||
● OPC UA Server | Data access (read, write, subscribe), runtime license required | Yes; Data access (read, write, subscribe), runtime license required | |
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
— User authentication | “anonymous” or by user name & password | Yes; “anonymous” or by user name & password | |
Further protocols | |||
● MODBUS | Yes; MODBUS TCP | Yes; MODBUS TCP | |
S7 message functions | |||
Number of login stations for message functions, max. | 32 | 32 | |
Program alarms | Yes | Yes | |
Number of configurable program messages, max. | 10 000 | 10 000 | |
Number of simultaneously active program alarms | |||
● Number of program alarms | 1 000 | 1 000 | |
● Number of alarms for system diagnostics | 200 | 200 | |
● Number of alarms for motion technology objects | 160 | 160 | |
Test commissioning functions | |||
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems | Yes; Parallel online access possible for up to 8 engineering systems | |
Status block | Yes; up to 8 simultaneously | Yes; up to 8 simultaneously | |
Single step | No | No | |
Status/control | |||
● Status/control variable | Yes | Yes | |
● Variables | Inputs, outputs, memory bits, DB, times, counters | Inputs, outputs, memory bits, DB, times, counters | |
● Number of variables, max. | |||
— of which status variables, max. | 200 | 200 | |
— of which control variables, max. | 200 | 200 | |
Forcing | |||
● Forcing | Yes | Yes | |
● Forcing, variables | Inputs, outputs | Inputs, outputs | |
● Number of variables, max. | 200 | 200 | |
Diagnostic buffer | |||
● present | Yes | Yes | |
● Number of entries, max. | 1 000 | 1 000 | |
— of which powerfail-proof | 300 | 300 | |
Traces | |||
● Number of configurable Traces | 4 | 4 | |
● Memory size per trace, max. | 512 kbyte | 512 kbyte | |
Interrupts/diagnostics/status information | |||
Diagnostics indication LED | |||
● RUN/STOP LED | Yes | Yes | |
● ERROR LED | Yes | Yes | |
● MAINT LED | Yes | Yes | |
Supported technology objects | |||
Motion Control | Yes | Yes | |
● Number of available Motion Control resources for technology objects | 2 400 | 2 400 | |
● Required Motion Control resources | |||
— per speed-controlled axis | 40; per axis | 40; per axis | |
— per positioning axis | 80; per axis | 80; per axis | |
— per synchronous axis | 160; per axis | 160; per axis | |
— per external encoder | 80; per external encoder | 80; per external encoder | |
— per output cam | 20; per cam | 20; per cam | |
— per cam track | 160; per cam track | 160; per cam track | |
— per probe | 40; per probe | 40; per probe | |
● Positioning axis | |||
— Number of positioning axes at motion control cycle of 4 ms (typical value) | 5 | 5 | |
— Number of positioning axes at motion control cycle of 8 ms (typical value) | 12 | 12 | |
Controller | |||
● PID_Compact | Yes; Universal PID controller with integrated optimization | Yes; Universal PID controller with integrated optimization | |
● PID_3Step | Yes; PID controller with integrated optimization for valves | Yes; PID controller with integrated optimization for valves | |
● PID-Temp | Yes; PID controller with integrated optimization for temperature | Yes; PID controller with integrated optimization for temperature | |
Counting and measuring | |||
● High-speed counter | Yes | Yes | |
Standards, approvals, certificates | |||
CE mark | Yes | Yes | |
CSA approval | Yes | Yes | |
cULus | Yes | Yes | |
FM approval | Yes | Yes | |
RCM (formerly C-TICK) | Yes | Yes | |
Ambient conditions | |||
Ambient temperature during operation | |||
● min. | 0 °C | 0 °C | |
● max. | Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load | Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load | |
● horizontal installation, min. | 0 °C | 0 °C | |
● horizontal installation, max. | 60 °C | 60 °C | |
● vertical installation, min. | 0 °C | 0 °C | |
● vertical installation, max. | 50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load | 50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load | |
Ambient temperature during storage/transportation | |||
● min. | -40 °C | -40 °C | |
● max. | 70 °C | 70 °C | |
Vibrations | |||
● Operation, tested according to IEC 60068-2-6 | Yes | Yes | |
● Transport, tested acc. to IEC 60068-2-6 | Yes | Yes | |
Shock testing | |||
● tested according to IEC 60068-2-6 | Yes | Yes | |
● tested according to IEC 60068-2-27 | Yes | Yes | |
● tested according to IEC 60068-2-29 | Yes | Yes | |
● Storage/transport, tested acc. to IEC 60068-2-27 | Yes | Yes | |
Operating systems | |||
pre-installed operating system | Windows Embedded Standard 7 E 32-bit | Windows Embedded Standard 7 P 64-bit | |
configuration / header | |||
configuration / programming / header | |||
Programming language | |||
— LAD | Yes | Yes | |
— FBD | Yes | Yes | |
— STL | Yes | Yes | |
— SCL | Yes | Yes | |
— CFC | No | No | |
— GRAPH | Yes | Yes | |
Know-how protection | |||
● User program protection/password protection | Yes | Yes | |
● Copy protection | Yes | Yes | |
● Block protection | Yes | Yes | |
Access protection | |||
● Protection level: Write protection | Yes | Yes | |
● Protection level: Read/write protection | Yes | Yes | |
● Protection level: Complete protection | Yes | Yes | |
programming / cycle time monitoring / header | |||
● lower limit | adjustable minimum cycle time | adjustable minimum cycle time | |
● upper limit | adjustable maximum cycle time | adjustable maximum cycle time | |
Open Development interfaces | |||
● Size of ODK SO file, max. | 3.8 Mbyte | 3.8 Mbyte | |
Peripherals/Options | |||
SD card | Optionally for additional mass storage | Optionally for additional mass storage | |
Dimensions | |||
Width | 160 mm | 160 mm | |
Height | 117 mm | 117 mm | |
Depth | 75 mm | 75 mm | |
Weights | |||
Weight, approx. | 0.83 kg | 0.83 kg |
Product type designation | CPU 1515SP PC |
HW functional status | FS05 |
Firmware version | V2.1 |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from | V14 SP1 |
version | |
Installed software | |
● Visualization | WinCC Runtime Advanced V14 SP1 |
● Control | S7-1500 Software Controller CPU 1505SP V2.1 |
Configuration control | |
via dataset | Yes |
Control elements | |
Mode selector switch | 1 |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms |
Input current | |
Current consumption (rated value) | 1.5 A; Full processor load, incl. ET 200SP modules and using USB |
Current consumption (in no-load operation), typ. | 0.6 A |
Inrush current, max. | 4.7 A; Rated value |
Power | |
Active power input, max. | 36 W; incl. ET 200SP modules and using USB |
Infeed power to the backplane bus | 8.75 W |
Power loss | |
Power loss, typ. | 15 W; without ET 200SP modules and without using USB |
Processor | |
Processor type | Dual-Core 1 GHz, AMD G Series APU T40E |
Memory | |
Type of memory | DDR3-SDRAM |
Main memory | 4 GB RAM |
CFast memory card | Yes; 30 GB flash memory |
SIMATIC memory card required | No |
Work memory | |
● integrated (for program) | 1 Mbyte |
● integrated (for data) | 5 Mbyte |
● integrated (for CPU function library of CPU | 10 Mbyte |
Runtime) | |
Load memory | |
● integrated (on PC mass storage) | 320 Mbyte |
Backup | |
● with UPS | Yes; all memory areas declared retentive |
● with non-volatile memory | Yes |
Weight | N/A |
---|---|
Dimensions | N/A |