SIMATIC ET 200AL – CM IO-Link – Siemens Communication Modules
USD $ 332.63
SKU: 6ES7147-5JD00-0BA0
The CM IO-Link communication module enables data exchange with up to 4 IO-Link devices.
IO-Link devices (e.g. sensors) with a Class A port are connected using a 3-wire cable. IO-Link devices that require additional supply voltage and have a Class B port (e.g. actuators) are connected using a 5-wire cable.
Thanks to the compatibility of IO-Link with standard sensors, commercially available sensors in accordance with IEC 61131 Type 1 can also be operated on the IO-Link master.
The 30 mm wide I/O modules are especially suitable for use in extremely confined spaces, have settable parameters and diagnostic functions and can thus be adapted flexibly to the respective process requirements.
Siemens Communication Modules SIMATIC ET 200AL Product Specifications:
Article number | 6ES7147-5JD00-0BA0 |
ET 200AL, cm 4x IO-Link, 4xM12 | |
General information | |
Product type designation | CM 4x IO-Link |
HW functional status | FS05 |
Firmware version | V1.2.x |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V13 SP1 or higher |
● STEP 7 configurable/integrated from version | From V5.5 SP4 Hotfix 3 |
● PROFIBUS from GSD version/GSD revision | GSD as of Revision 5 |
● PROFINET from GSD version/GSD revision | GSDML V2.3.1 |
Supply voltage | |
power supply according to NEC Class 2 required | No |
Load voltage 1L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Load voltage 2L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes; against destruction; load increasing |
Input current | |
Current consumption (rated value) | 40 mA; without load |
from load voltage 1L+ (unswitched voltage) | 4 A; Maximum value |
from load voltage 2L+, max. | 4 A; Maximum value |
Encoder supply | |
Number of outputs | 4 |
24 V encoder supply | |
● Short-circuit protection | Yes; per module, electronic |
● Output current, max. | 1.4 A; Total current of all ports |
Power loss | |
Power loss, typ. | 2.6 W |
IO-Link | |
Number of ports | 4 |
● of which simultaneously controllable | 4 |
IO-Link protocol 1.0 | Yes |
IO-Link protocol 1.1 | Yes |
Transmission rate | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230 kBaud (COM3) |
Size of process data, input per port | 32 byte |
Size of process data, input per module | 132 byte |
Size of process data, output per port | 32 byte |
Size of process data, output per module | 128 byte |
Memory size for device parameter | 2 kbyte; for each port |
Master backup | Possible with function block IO_LINK_MASTER |
Configuration without S7-PCT | Possible; autostart/manual function |
Cable length unshielded, max. | 20 m |
Operating modes | |
● IO-Link | Yes |
● DI | Yes |
● DQ | Yes; max. 100 mA |
Connection of IO-Link devices | |
● Port type A | Yes; via 3-core cable |
● Port type B | Yes; Additional device supply: 1.6 A total current of all ports |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes; Parameterizable |
Diagnoses | |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes |
● Short-circuit | Yes |
Diagnostics indication LED | |
● Channel status display | Yes; green LED |
● for module diagnostics | Yes; green/red LED |
● For load voltage monitoring | Yes; green LED |
Potential separation | |
between the load voltages | Yes |
Potential separation channels | |
● between the channels | No |
● between the channels and backplane bus | Yes |
● between the channels and the power supply of the electronics | No |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Degree and class of protection | |
IP degree of protection | IP65/67 |
Standards, approvals, certificates | |
Suitable for safety-related tripping of standard modules | Yes; From FS01 |
Highest safety class achievable for safety-related tripping of standard modules | |
● Performance level according to ISO 13849-1 | PL d |
● Category according to ISO 13849-1 | Cat. 3 |
● SILCL according to IEC 62061 | SILCL 2 |
Ambient conditions | |
Ambient temperature during operation | |
● min. | -30 °C |
● max. | 55 °C |
connection method / header | |
Design of electrical connection for the inputs and outputs | M12, 5-pole |
Design of electrical connection for supply voltage | M8, 4-pole |
ET-Connection | |
● ET-Connection | M8, 4-pin, shielded |
Dimensions | |
Width | 30 mm |
Height | 159 mm |
Depth | 40 mm |
Weights | |
Weight, approx. | 145 g |
Weight | 0.169 kg |
---|---|
Dimensions | 4.5 × 17.6 × 4 cm |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details